<strong>Valve</strong> <strong>Terminal</strong> <strong>System</strong>, <strong>Series</strong> <strong>HF04</strong>Version 35: AS-i, B-Design, <strong>HF04</strong> with ASI 4DO-AUX PowerTechnical DataDegree of protection according toEN 60 529/IEC 529Ambient temperature rangeIP 65 when assembled0° C to +50° C (32 °F to +122 °F)AS-i busI/O code 8ID code / ID2 codeF / ERated voltageaccording to AS-i specifcations 26,5 - 31,6 VPower consumption50 mALoad supply 24 V DC externalRated voltage 24 V DC (–10% / +10%)Protective min. voltage (PELV) according to IEC 60364-4-41Residual ripple 0,5 %Rated current per valve solenoid30 mAElectromagnetic compatibilityInterference radiation EN 50295Interference irradiation EN 50295You can find the allocation schemes for individual products in the manuals or contact yournearest Bosch Rexroth sales office.Application AreaThis AS-i bus module comply with the AS-i specification V2.11 Rev. 1 (Jan. 31, 2001).AS-Interface module (as spare part or for retrofitting of a <strong>HF04</strong> valve unit, Sub-D)Module Manual Code No.Module for max. 4 coils (AS-i 4DO-AUX) R 499 050 017 R 412 003 488Incl. mounting screw and seal kitAccessories electronics (to be ordered separately)AccessoriesCode No.AS-i cable socket (1 piece) incl. Label 1 824 484 064Addressing cableon request8