Knürr CoolBlast® Top-Mounting Fan for Miracel®

Knürr CoolBlast® Top-Mounting Fan for Miracel®

Knürr CoolBlast® Top-Mounting Fan for Miracel®

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Knürr AccessoriesKnürr AccessoriesKnürr CoolBlast ®<strong>Top</strong>-<strong>Mounting</strong> <strong>Fan</strong>Strong points 1.109Products 1.110<strong>Fan</strong> <strong>Top</strong> 1.113Knürr CoolBlast ®<strong>Top</strong>-<strong>Mounting</strong><strong>Fan</strong> <strong>for</strong> Miracel ®<strong>Top</strong>-<strong>Mounting</strong> <strong>Fan</strong>s 1.116Knürr CoolBlast ®<strong>Fan</strong> UnitStrong points 1.117Products 1.118Accessories 1.121Filter <strong>Fan</strong> 1.124Accessories 1.125Knürr CableManagementStrong points 1.127Products 1.129Knürr SystemAccessoriesProducts 1.1391.108


Knürr CoolBlast ®Knürr CoolBlast ® <strong>Top</strong>-<strong>Mounting</strong> <strong>Fan</strong>Strong points1 The constantly increasing power loss inelectronic modules constantly increasesheat loads in the rack.The CoolBlast ® is modularly configured sothat a suitable solution can be selected <strong>for</strong>every heat load.2 The CoolBlast ® top-mounting fan is there<strong>for</strong>eavailable in models with two, three or six fans.Regulated, thermostat-controlled and unregulatedmodels are provided.3 An optional fan lid or an optional filter (seepicture) prevent dust from penetratingwhen the fan is in standstill mode.4 The recently developed protection grid ofthe CoolBlast ® top-mounting fan minimizesthe pressure loss of through-flowing airand reduces the airflow noise TheCoolBlast ® roof fan is an especially quietsystem.1 LUF20124 LUF201752 LUF201623 LUF20121Possible configurations:4 LUF20124 <strong>Fan</strong> <strong>Top</strong>Consists of Figure Questions be<strong>for</strong>e installation in Miracel:1. How wide and deep is the rack?2. For 2, 3 or 6-piece fan unit?3. What power supply will be required?4. What volume flow is targeted?5. What pressure?<strong>Fan</strong> <strong>Top</strong> 1 + 2plus CoolBlast ®6. With or without regulated or thermostatcontrolledCoolBlast ® model?7. Correct mains cable?8. Is particulate matter protection required?<strong>Fan</strong> top 1 + 2 + 3plus CoolBlast ®plus filter(<strong>Fan</strong> lid and filter)1.109


Knürr CoolBlast ® SP = Standard Per<strong>for</strong>mance ΔP = Pressure increase (Pi)Knürr CoolBlast ® <strong>Fan</strong> Unit <strong>for</strong> roof/door installationUnregulatedLUF20203– For <strong>for</strong>ced rack cooling– Suitable <strong>for</strong> installation at any time in theMiracel ® top– DC versions and 115 VAC versions on request(see CoolBlast ® fan units)■ MaterialHousing: Sheet steel, high-grade steel grid■ FinishZinc-passivated■ Single fan technical dataSee page 12.9■ ApprovalsCE Symbol in acc. with Low Voltage Directive73/23/EEC, EMC directive 89/366/EEC■ Supply schedule1 CoolBlast fan unit ®1 mains cable, 3 m with safety plug (230VAC)<strong>Mounting</strong> materialOperating instructions■ How suppliedAssembled, wired and tested■ NotePlease also order specific mains cableLUF20205LUF20124LUF20175Name Model Elec. connection P(W) V·(m3/h) ΔP(Pa) p(dB(A)) Order no. UPCoolBlastT 230V 2-piece 207...253 VAC; 50/60 Hz 30 330 74 43.4 03.027.300.1 1 unitCoolBlastT 230V 3-piece 207...253 VAC; 50/60 Hz 45 495 74 45.2 03.027.301.1 1 unitCoolBlastT 230V 6-piece 207...253 VAC; 50/60 Hz 90 990 74 48.8 03.027.302.1 1 unitDimensions in mm: W = WidthU = standard height unitH = Height1 U = 44.45 mmD = DepthUP = unit of packagingh = installation height kg = weightd = useful depthL = length= Express itemConversion: 1 mm = 0.03937 inch 1 kg = 2.2046 poundHP = High per<strong>for</strong>manceI nom = Nom. current (A)UP = Ultra high per<strong>for</strong>mance I max = Max. residual current (A)V = Voltage (400V = 3-phase)n = Number of fans p = Sound pressure (dB(A)) in 1 mP = Power consumption (W) from the rackV . = Air volume flow (m3/h) (600 mm x 600 mm; raisedΔV . = Airflow volume loss (%)cover)1.110


Knürr CoolBlast ®Knürr CoolBlast ® <strong>Fan</strong> Unit <strong>for</strong> roof/door installationThermostat-controlledLUF20204– For <strong>for</strong>ced rack cooling– Suitable <strong>for</strong> installation at any time in theMiracel ® top– 115 VAC versions on request– <strong>Fan</strong> function (ON/OFF) thermostatcontrolled,setting from 0° to +60° C■ MaterialHousing: Sheet steel, high-grade steel grid■ FinishZinc-passivated■ Single fan technical dataSee page 12.9■ ApprovalsCE Symbol in acc. with Low Voltage Directive73/23/EEC, EMC directive 89/366/EEC■ Supply schedule1 CoolBlast fan unit ®1 mains cable, 3 m with safety plug (230VAC)<strong>Mounting</strong> materialOperating instructions■ How suppliedAssembled, wired and tested■ NotePlease also order specific mains cableLUF20206LUF20124LUF20175Name Model Elec. connection P(W) V(m3/h) ΔP(Pa) p(dB(A)) Order no. UPCoolBlastT 230V 2-piece Thermostat 207...253 VAC; 50/60 Hz 30 330 74 43.4 03.027.310.1 1 unitCoolBlastT 230V 3-piece Thermostat 207...253 VAC; 50/60 Hz 45 495 74 45.2 03.027.311.1 1 unitCoolBlastT 230V 6-piece Thermostat 207...253 VAC; 50/60 Hz 90 990 74 48.8 03.027.312.1 1 unitDimensions in mm: W = WidthU = standard height unitH = Height1 U = 44.45 mmD = DepthUP = unit of packagingh = installation height kg = weightd = useful depthL = length= Express itemConversion: 1 mm = 0.03937 inch 1 kg = 2.2046 poundSP = Standard Per<strong>for</strong>mance ΔP = Pressure increase (Pi)HP = High per<strong>for</strong>manceI nom = Nom. current (A)UP = Ultra high per<strong>for</strong>mance I max = Max. residual current (A)V = Voltage (400V = 3-phase)n = Number of fans p = Sound pressure (dB(A)) in 1 mP = Power consumption (W) from the rackV . = Air volume flow (m3/h) (600 mm x 600 mm; raisedΔV . = Airflow volume loss (%)cover)1.111


Knürr CoolBlast ® SP = Standard Per<strong>for</strong>mance ΔP = Pressure increase (Pi)Knürr CoolBlast ® <strong>Fan</strong> Unit <strong>for</strong> roof/door installationSpeed-controlledLUF20160– For <strong>for</strong>ced rack cooling– Suitable <strong>for</strong> installation at any time in theMiracel ® top– DC version on request (see CoolBlast ® fanunits)– Settable reference temperature (20° to 55°C)– Speed control, 30 to 100%, with sensor break100% rotation– Individual fan monitoring– Floating common alarm output <strong>for</strong> excesstemperature alarm and fan failure– Optical status display <strong>for</strong> O.K., excess temperatureand fan failure– Acoustic warning incl. reset button■ MaterialHousing: Sheet steel, high-grade steel grid■ FinishZinc-passivated front panel, powder-coated,smooth in RAL 7035 light gray■ Single fan technical dataSee page 12.9■ ApprovalsCE Symbol in acc. with Low Voltage Directive73/23/EEC, EMC directive 89/366/EEC■ Supply schedule1 CoolBlast fan unit ®1 sensor cable, 2 m (plug-in)1 signal cable, 2 m (plug-in)1 mains cable, 3 m with safety plug (230VAC)<strong>Mounting</strong> materialOperating instructions■ How suppliedAssembled, wired and tested■ NotePlease also order specific mains cableLUF20161LUF20124LUF20175Name Model Elec. connection P(W) V· (m3/h) ΔP(Pa) p(dB(A)) Order no. UPCoolBlastT 230V 3-piece controlled SP 100...253 VAC; 50/60 Hz 25 553 68 49.6 03.027.321.1 1 uniCoolBlastT 230V 6-piece controlled SP 100...253 VAC; 50/60 Hz 48 1106 68 53.3 03.027.322.1 1 unitCoolBlastT 230V 3-piece controlled HP 100...253 VAC; 50/60 Hz 32 711 173 55.8 03.027.324.1 1 unitCoolBlastT 230V 6-piece controlled HP 100...253 VAC; 50/60 Hz 62 1422 173 59.1 03.027.325.1 1 unitDimensions in mm: W = WidthU = standard height unitH = Height1 U = 44.45 mmD = DepthUP = unit of packagingh = installation height kg = weightd = useful depthL = length= Express itemConversion: 1 mm = 0.03937 inch 1 kg = 2.2046 poundHP = High per<strong>for</strong>manceI nom = Nom. current (A)UP = Ultra high per<strong>for</strong>mance I max = Max. residual current (A)V = Voltage (400V = 3-phase)n = Number of fans p = Sound pressure (dB(A)) in 1 mP = Power consumption (W) from the rackV . = Air volume flow (m3/h) (600 mm x 600 mm; raisedΔV = Airflow volume loss (%)cover)1.112


Knürr CoolBlast ®<strong>Fan</strong> <strong>Top</strong> <strong>for</strong> Knürr CoolBlast ®– For use in conjunction with the CoolBlast fanunit– Suitable <strong>for</strong> installation in Miracel– With cable routing (sliding top)– Cover divided in two parts <strong>for</strong> later installationand <strong>for</strong> servicing■ Supply schedule1 top cover with cover strip and cable entry2 covers■ How suppliedPreassembledLUF20163■ MaterialSheet steel■ Finish / ColorFinal digit of order number .1:- Powder-coated texture, RAL 7035- Light grayFinal digit of order number .8:- Powder-coated texture, RAL 7021- Dark grayLUF20169(without fan)LUF20176W H D Model Order no. UP600 600 For 2 or 3-piece 01.149.031.X 1 unit700 600 For 2 or 3-piece 01.149.041.X 1 unit800 600 For 2 or 3-piece 01.149.051.X 1 unit600 800 For 2/3 or 6-piece 01.149.033.X 1 unit700 800 For 2/3 or 6-piece 01.149.043.X 1 uni800 800 For 2/3 or 6-piece 01.149.053.X 1 unit600 900 For 2/3 or 6-piece 01.149.034.X 1 unit700 900 For 2/3 or 6-piece 01.149.044.X 1 unit800 900 For 2/3 or 6-piece 01.149.054.X 1 unit600 1000 For 2/3 or 6-piece 01.149.035.X 1 unit700 1000 For 2/3 or 6-piece 01.149.045.X 1 unit800 1000 For 2/3 or 6-piece 01.149.055.X 1 unit600 1200 For 2/3 or 6-piece 01.149.037.X 1 unit800 1200 For 2/3 or 6-piece 01.149.057.X 1 unitDust and Particle Protection <strong>for</strong> CoolBlast ®Solution 1: Filter matLUF20121– For use in conjunction with the CoolBlast ® fantop– Easy filter covering so that dust cannot penetratewhen the fan is stopped (regulated orthermostat-controlled version)– For all top sizes; filter and adhesive tape canbe cut to the required length■ MaterialFiledon (filter class - G2)■ Supply schedule1 filterAdhesive tape■ How suppliedFlat-packed kitW H D kg Model Order no. UPFor 2, 3 or 6-piece fan unit 01.149.101.9 1 setLUF201681.113


Knürr CoolBlast ® SP = Standard Per<strong>for</strong>mance ΔP = Pressure increase (Pi)Dust and particle protection <strong>for</strong> Knürr CoolBlast ®Solution 2: Vent LidLUF20174– For use in conjunction with the CoolBlast ®fan top– Closed top cover with cable entry <strong>for</strong> protectionagainst <strong>for</strong>eign particles and dust– <strong>Mounting</strong> on the spacer bolts on the standardcover■ MaterialSheet steel■ Finish / ColorFinal digit of order number .1:- Powder-coated texture, RAL 7035,- Light grayFinal digit of order number .8:- Powder-coated texture, RAL 7021,- Dark gray■ Supply schedule1 top cover with cable entry■ How suppliedFlat-packed kitLUF20172W H D Model Order no. UP600 600 With cable entry 01.149.031.X 1 unit700 600 With cable entry 01.149.041.X 1 unit800 600 With cable entry 01.149.051.X 1 unit600 800 With cable entry 01.149.033.X 1 unit700 800 With cable entry 01.149.043.X 1 uni800 800 With cable entry 01.149.053.X 1 unit600 900 With cable entry 01.149.034.X 1 unit700 900 With cable entry 01.149.044.X 1 unit800 900 With cable entry 01.149.054.X 1 unit600 1000 With cable entry 01.149.035.X 1 unit700 1000 With cable entry 01.149.045.X 1 unit800 1000 With cable entry 01.149.055.X 1 unit600 1200 With cable entry 01.149.037.X 1 unit800 1200 With cable entry 01.149.057.X 1 unit600 600 Closed 01.130.690.X 1 unit700 600 Closed 01.130.694.X 1 unit800 600 Closed 01.130.691.X 1 unit600 800 Closed 01.130.691.X 1 unit700 800 Closed 01.130.695.X 1 unit800 800 Closed 01.130.699.X 1 unit600 900 Closed 01.130.692.X 1 unit700 900 Closed 01.130.696.X 1 unit800 900 Closed 01.130.700.X 1 unit600 1000 Closed 01.127.700.X 1 unit700 1000 Closed 01.127.701.X 1 unit800 1000 Closed 01.127.702.X 1 unitLUF20177LUF20178Dimensions in mm: W = WidthU = standard height unitH = Height1 U = 44.45 mmD = DepthUP = unit of packagingh = installation height kg = weightd = useful depthL = length= Express itemConversion: 1 mm = 0.03937 inch 1 kg = 2.2046 poundHP = High per<strong>for</strong>manceI nom = Nom. current (A)UP = Ultra high per<strong>for</strong>mance I max = Max. residual current (A)V = Voltage (400V = 3-phase)n = Number of fans p = Sound pressure (dB(A)) in 1 mP = Power consumption (W) from the rackV . = Air volume flow (m3/h) (600 mm x 600 mm; raisedΔV . = Airflow volume loss (%)cover)1.114


Knürr CoolBlast ®Knürr CoolBlast ® <strong>Fan</strong> Installation SetWith thermostatLUF20180– For quick and easy <strong>for</strong>ced exhaustion of racks– Miracel / Tecoras Indoor– Installation in the top cover area– No loss of 19’’ installation space– Later installation also possible– Incl. 2 fans (160 m3/h per fan)■ Material / FinishSheet steel, 1.5 mm, zinc-passivated■ ApprovalsCE Symbol in acc. with Low Voltage Directive73/23/EEC, EMC directive 89/336/EEC■ Technical data: Thermostat- Setting range: + 0°C ... + 60°C- Power supply: 240 V / 50 Hz- Mains current: 16 A■ Supply schedule1 mounting panel <strong>for</strong> fan2 fans1 connection cable, 2.0 m with safety plugType 1: with thermostatType 2: without thermostat<strong>Mounting</strong> material■ How suppliedAssembled, wired and testedW H D For rack type Order no. UP534 Miracel / W 600 / with thermostat 01.113.430.0 1 unit734 Miracel / W 800 / with thermostat 01.113.431.0 1 unit1.115


Knürr <strong>Top</strong>-<strong>Mounting</strong> <strong>Fan</strong>Silent <strong>Top</strong>-<strong>Mounting</strong> <strong>Fan</strong>LUF20194– For <strong>for</strong>ced rack cooling– Suitable <strong>for</strong> installation in Miracel– High volume flow with low noise generation(e.g. <strong>for</strong> office applications)■ Material / FinishSheet steel■ Single fan technical dataMax. volume current (free blowing): 1500 m 3 /hVoltage/frequency: 230 V / 50 HzPower consumption: 117 WNoise: 40 dB(A)Temperature range: -25…40°C■ Finish / ColorFinal digit of order number .1:- Powder-coated texture, RAL 7035- Light grayFinal digit of order number .8:- Powder-coated texture, RAL 7021- Dark gray■ Supply schedule1 top-mounting fan1 mains cable, 3 m with safety plug(230 VAC)<strong>Mounting</strong> material■ How suppliedFlat-packed kit■ NotePlease also order suitable topW H D For rack type Order no. UP449 237 490 Miracel 03.028.111.X 1 unitLUF20195<strong>Fan</strong> top <strong>for</strong> Silent top-mounting fanLUF20163Sim. to picture– For use in conjunction with the Silent fan top– Suitable <strong>for</strong> installation in Miracel– With cable routing (sliding top)– Cover divided in two parts <strong>for</strong> later installationand <strong>for</strong> servicing■ Material/ FinishSheet steel■ Finish / ColorFinal digit of order number .1:- Powder-coated texture, RAL 7035,- Light grayFinal digit of order number .8:- Powder-coated texture, RAL 7021,- Dark gray■ Supply schedule1 top cover with cover strip and cable entry<strong>Mounting</strong> material■ How suppliedFlat-packed kitW H D For rack type Order no. UP600 600 Miracel 01.149.201.x 1 uni700 600 Miracel 01.149.202.x 1 unit800 600 Miracel 01.149.203.x 1 unitLUF20195600 800 Miracel 01.149.206.x 1 unit700 800 Miracel 01.149.207.x 1 unit800 800 Miracel 01.149.208.x 1 unit600 900 Miracel 01.149.211.x 1 unit700 900 Miracel 01.149.212.x 1 unit800 900 Miracel 01.149.213.x 1 unit600 1000 Miracel 01.149.216.x 1 unit700 1000 Miracel 01.149.217.x 1 unit800 1000 Miracel 01.149.218.x 1 unit600 1200 Miracel 01.149.221.x 1 unit700 1200 Miracel 01.149.222.x 1 unit800 1200 Miracel 01.149.223.x 1 unit1.116


Knürr CoolBlast ®1 LUF201252 LUF20056Knürr CoolBlast ® <strong>Fan</strong> UnitStrong pointsThe constantly increasing powerlosses of electronic modules makehigh demands on the effective coolingof electronic modules. Large airflowvolumes ensure secured heatdissipation, whereby higher airflowspeeds reach the components, whichleads to better heat transfer.The packing density of the electronicsin the racks is also increasing. <strong>Fan</strong>swith high pressure jump overcomethe resulting higher increasedpressure loss.The space-saving 1 U constructionguarantees maximum installationspace <strong>for</strong> our customers' equipment.1 The CoolBlast ® fan unit fromKnürr is available as a slot-in unitwith 3 and 6 fans <strong>for</strong> verticalventilation of installed modules.The volume flow required <strong>for</strong>cooling is primarily determinedby the selection of fans, whichare available in three differentper<strong>for</strong>mance classes (Standard,High and Ultra High Per<strong>for</strong>mance).Selection can be made betweenquiet axial fans and specialdiagonal fans with an especiallyhigh support rate <strong>for</strong> cooling air.with the rack monitoring system(RMS).A simple thermostat-controlledmodel is also available.4 Optimum heat dissipation of thecooled module is attained withthe high airflow volumes andpressure jumps in the CoolBlast ®fan unit. Building-specific CFDsimulations can optimize eachcustomer thermal managementapplication.5 Air conduction components,optional with filter, round offthe product range. The filtermat protects the electroniccomponents in use from dirt buildupsand dust, and can be swappedout during running operation.In addition to the CoolBlast ®fan unit, a number of othercomponents and accessory partsare also available <strong>for</strong> thermalmanagement in server andnetwork rack systems.1 LUF201401.1172 To ensure that plenty of coolingair reaches the electroniccomponents, CoolBlast ® has anIP protective grid with high freecross-section surface. The grid<strong>for</strong>m minimizes the pressureloss of the streaming airflow andreduces the streaming noise.3 LUF200545 LUF201334 LUF200773 The Knürr CoolBlast ® adjusts itscooling airflow to the power loss tobe cooled.The temperature-regulated controlof the fan rotation optimizes thenoise emission and the lifespan ofthe fans. The maximum referencetemperature is set at the front. Afan failure detector ensures highoperational reliability. Exceedingthe reference temperature is alsodetected in the same way. Thefault signal can be connected


Knürr CoolBlast ®Knürr CoolBlast ® <strong>Fan</strong> Unit, uncontrolledLUF20125– <strong>Fan</strong> unit <strong>for</strong> vertical cooling of modules in19” racks– Chassis rails are recommended <strong>for</strong> mounting.Chassis rails are required with 6-pieceCoolBlast.■ MaterialSheet steel, high-grade steel grid■ Finish/colorHousing, zinc-passivatedFront panel, powder-coated, smooth inRAL 7035 light gray■ How suppliedAssembled, wired and tested■ ApprovalsCE Symbol in acc. with Low Voltage Directive73/23/EEC, EMC Directive 89/366/EEC■ Supply schedule1 CoolBlast fan unit, packed with operatinginstructions.1 connection cable, 2 m Euro cable■ NotePlease also order specific mains cable(see page 1.125)!LUF20139Na W H D kg n Elec. connection P(W) V (m3/h) ΔP(Pa) p(dB(A)) Order no.CoolBlast 230V 3-piece 440 43.6 230 3 3 207 ... 253VAC; 50/60Hz 45 495 74 45.2 03.027.001.1CoolBlast 230V 6-piece 440 43.6 390 6 6 207 ... 253VAC; 50/60Hz 90 990 74 48.8 03.027.002.1CoolBlast 115V 3-piece 440 43.6 230 3 3 103.5 ... 126.5VAC; 50/60Hz 44 576 88 47.3 03.027.004.1CoolBlast 115V 6-piece 440 43.6 390 6 6 103.5 ... 126.5VAC; 50/60Hz 88 1152 88 50.8 03.027.005.1Knürr CoolBlast ® fan unit, thermostat-controlledLUF20127LUF20138– <strong>Fan</strong> unit <strong>for</strong> vertical cooling of modules in19” racks– <strong>Fan</strong> function (ON/OFF) thermostatcontrolled,setting from 0°C to 60°C– Chassis rails are recommended <strong>for</strong> mounting.Chassis rails are required with 6-pieceCoolBlast.■ MaterialSheet steel, high-grade steel grid■ Finish/colorHousing, zinc-passivatedFront panel, powder-coated, smooth inRAL 7035 light gray■ How suppliedAssembled, wired and tested■ ApprovalsCE Symbol in accordance with Low VoltageDirective 73/23/EEC, EMC Directive 89/366/EEC■ Supply schedule1 CoolBlast fan unit, packed with operatinginstructionsOnly with DC devices:1 connection cable, 2 m with connector plugand free endsOnly with 230V AC devices:1 connection cable, 2 m Euro cableName W H D kg n Elec. connection P(W) V(m3/h) ΔP(Pa) p(dB(A)) Order no.CoolBlast 230V 3-piece thermostat 440 43.6 230 3 3 207 ... 253VAC; 50/60Hz 45 495 74 45.2 03.027.011.1CoolBlast 230V 6-piece thermostat 440 43.6 390 6 6 207 ... 253VAC; 50/60Hz 90 990 74 48.8 03.027.012.1CoolBlast 115V 3-piece thermostat 440 43.6 230 3 3 103.5 ... 126.5VAC; 50/60Hz 44 576 88 47.3 03.027.014.1CoolBlast 115V 6-piece thermostat 440 43.6 390 6 6 103.5 ... 126.5VAC; 50/60Hz 88 1152 88 50.8 03.027.015.11.118


Knürr CoolBlast ®LUF20128LUF20140Knürr CoolBlast ® <strong>Fan</strong> Unit,speed-controlled– <strong>Fan</strong> unit <strong>for</strong> vertical cooling of modules in19” racks– Reference temperature can be set (20°C to55°C)– Speed control, 30 to 100%, with sensor break100% rotation– Individual fan monitoring– Digital alarm output <strong>for</strong> excess temperaturealarm and fan failure– Optical status display <strong>for</strong> O.K., excesstemperature and fan failure– Acoustic warning with push-button– Chassis rails are recommended <strong>for</strong> mounting.Chassis rails are required with 6-pieceCoolBlast.■ MaterialSheet steel, high-grade steel grid■ Finish/colorHousing, zinc-passivatedFront panel, powder-coated, smoothin RAL 7035 light grayApprovalsCE Symbol in accordance with Low VoltageDirective 73/23/EEC, EMC Directive 89/366/EEC■ Supply schedule1 CoolBlast fan unit, packed with operatinginstructions1 sensor cable, 2 m (plug-in)1 signal cable, 2 m (plug-in)Only with DC devices:1 connection cable, 2 m with connector plugand free endsOnly with AC devices:1 connection cable, 2 m Euro cable■ How suppliedAssembled, wired and tested■ NoteFurther characteristics can be implementedproject-related in line with standards.LUF20179Name W H D kg n Elec. connection P(W) V • (m3/h) ΔP(Pa) p(dB(A)) Order no.CoolBlast 115/230V, 3-piece regulated SP 440 43.6 230 3.2 3 100 to 253VAC; 50/60Hz 25 553 68 49.6 03.027.021.1CoolBlast 115/230V, 6-piece regulated SP 440 43.6 390 6.2 6 100 to 253VAC; 50/60Hz 48 1106 68 53.3 03.027.022.1CoolBlast 115/230V, 3-piece regulated HP 440 43.6 230 3.2 3 100 to 253VAC; 50/60Hz 32 711 173 55.8 03.027.024.1CoolBlast 115/230V, 6-piece regulated HP 440 43.6 390 6.2 6 100 bis 253VAC; 50/60Hz 62 1422 173 59.1 03.027.025.1CoolBlast 24/48V, 3-piece regulated SP 440 43.6 230 3.1 3 20 bis 60VDC 25 553 68 49.6 03.027.051.1CoolBlast 24/48V, 6-piece regulated SP 440 43.6 390 6.1 6 20 bis 60VDC 48 1106 68 53.3 03.027.052.1CoolBlast 24/48V, 3-piece regulated HP 440 43.6 230 3.1 3 20 bis 60VDC 32 711 173 55.8 03.027.054.1CoolBlast 24/48V, 6-piece regulated HP 440 43.6 390 6.1 6 20 bis 60VDC 62 1422 173 59.1 03.027.055.1Dimensions in mm: W = Width U = standard height unitH = Height1 U = 44.45 mmD = Depth UP = unit of packagingh = installation height kg = weightd = useful depthL = length= Express itemConversion: 1 mm = 0.03937 inch1 kg = 2.2046 poundSP = Standard Per<strong>for</strong>mance ΔP = Pressure increase (Pi)HP = High per<strong>for</strong>manceI nom = Nom. current (A)UP = Ultra high per<strong>for</strong>mance I max = Max. residual current (A)V = Voltage (400V = 3-phase)n = Number of fans p = Sound pressure (dB(A)) in 1 mP = Power consumption (W) from the rackV . = Air volume flow (m3/h)(600 mm x 600 mm;ΔV . = Airflow volume loss (%)raised cover)1.119


Knürr CoolBlast ®Knürr CoolBlast ® Airflow via Front IntakeStrong pointsLUF20148The front intake unit <strong>for</strong> the KnürrCoolBlast ® used <strong>for</strong> the targetedcooling of module units that aresituated on top of one another (heatsources).1 The optimized airflow guidesthe cooled air specifically to therear. (See graphic 1). This preventsincreased warming up of thevertical airflows from module chassisto module chassis. (See graphic 2).2 The optionally available front panelcan be mounted later on and isoften used <strong>for</strong> optical appearancereasons.3 The filter mat protects theelectronic components in use fromdirt build-ups and dust, and theycan also be swapped out duringrunning operation.1 LUF200562 LUF201363 LUF20146OptimumLUF20156Little effectLUF20157Possible configurations:Const. of Fig. Order no. Airflow volume loss3-piece 6-piece 3-piece 6-pieceAirflow 1 03.027.094.1 03.027.095.1 30 % 45 %Airflow 1 + 2 03.027.094.1 03.027.095.1 40 % 55 %plus front panel 03.027.097.1 03.027.097.1Airflow 1 + 2 + 3 03.027.094.1 03.027.095.1 50 % 60 %plus front panel 03.027.097.1 03.027.097.1and filter 03.027.098.1 03.027.099.1.120


Knürr CoolBlast ®Knürr CoolBlast® Airflow viaFront Intake, 1 U19” Filter Unit, 1 ULUF20131– For CoolBlast ® fan unit, 3-piece and6-piece <strong>for</strong> front intake– Use as cooling baffle– Can be supplemented with front paneland filter mat■ MaterialSheet steel■ Finish/colorPowder-coated texture, RAL 7035light grayLUF00205– Suitable <strong>for</strong> use with the CoolBlast ® fanunit– Adjusted to the respective chassis depth■ MaterialHousing: Sheet steelFront panel: ABS (UL94 V-0)Handle: Extruded aluminumFilter: Viledon P 15/150■ Filter classG2LUF20142■ Supply schedule1 air guide■ How suppliedIn unitsW H D Model Order no. UP43.6 230 For 3-piece 03.027.094.1 1 unit43.6 390 For 6-piece 03.027.095.1 1 unitKnürr CoolBlast® Front Panel<strong>for</strong> airflow via front intake, 1 U– For use with the front intake air guide– Can be mounted later on■ Finish/colorHousing: Powder-coated texture- RAL 9011 blackFront panel: RAL 7035- Light grayHandle: Powder-coated texture- RAL 5008 gray-blue■ Supply schedule1 filter unit1 filter■ How suppliedIn unitsW H D kg W n Model Order no. UP43.6 282 2.0 03.025.250.1 1 unit43.6 660 4.0 03.025.253.1 1 unitLUF20136■ MaterialSheet steel■ Finish/colorPowder-coated texture, RAL 7035light gray, smooth■ Supply schedule1 front panel■ How suppliedIn unitsLUF00280Replacement Filter– For 19” filter insert■ MaterialFilter: Viledon P 15/150■ Filter classG2W H D Model Order no. UP43.6 03.027.097.1 1 unitKnürr CoolBlast ®Filter <strong>for</strong> front intake■ Supply schedule1 filter■ How suppliedIn unitsW H D kg W n Model Order no. UP282 03.025.246.9 1 unit660 03.025.249.9 1 unit- For use with the front intake air guide- Can be mounted later on and filter can beswapped out during running operationLUF20135■ Filter classG2■ MaterialViledon K15/150■ Supply schedule1 filter■ How suppliedIn unitsDimensions in mm: W = WidthH = HeightD = Depthh = installation heightd = useful depthL = lengthU = standard height unit1 U = 44.45 mmUP = unit of packagingkg = weight= Express itemConversion: 1 mm = 0.03937 inch1 kg = 2.2046 poundW H D Model Order no. UP400 160 For 3-piece 03.027.098.1 1 unit400 320 For 6-piece 03.027.099.1 1 unitSP = Standard Per<strong>for</strong>mance ΔP = Pressure increase (Pi)HP = High per<strong>for</strong>manceI nom = Nom. current (A)UP = Ultra high per<strong>for</strong>mance I max = Max. residual current (A)V = Voltage (400V = 3-phase)n = Number of fans p = Sound pressure (dB(A)) in 1 mP = Power consumption (W) from the rackV . = Air volume flow (m3/h)(600 mm x 600 mm;ΔV . = Airflow volume loss (%)raised cover)1.121


Knürr CoolBlast ®Axial single fan technical dataKnürr CoolBlast®Knürr CoolBlast®ID number 01.914.070.9 01.914.075.9Dim: L x W x H 119 x 119 x 38 119 x 119 x 38 119 x 119 x 38Max. volume flow, free blowing 184.2 m3/h 237 m3/hVoltage 24 VDC 24 VDCFrequencyPower consumption 7.4 W 11 WNoise, free blowing 43 dB(A) 59 dB(A)Bearing system Ball bearing Ball bearingNominal speed 2950 min-1 4400 min-1Permis. ambient temp. -10 °C to +70 °C -30 °C to +55 °CService life L10 at 40°C 75,000 h 70,000 hApprovals CE, VDE CE, VDEUse in fan unit: 03.027.021.1 03.027.024.103.027.022.1 03.027.025.103.027.051.1 03.027.054.103.027.052.1 03.027.055.103.027.321.1 03.027.324.103.027.322.1 03.027.325.1Knürr CoolBlast® Knürr CoolBlast® Knürr CoolBlast®ID number 01.914.050.9 01.914.051.9 01.914.051.9-2Dim: L x W x H 119 x 119 x 38 119 x 119 x 38 119 x 119 x 38Max. volume flow, free blowing 192 m3/h 165 m3/h 120 m3/hVoltage 115 VAC 230 VAC 230 VACFrequency 50 Hz 50 Hz 50 HzPower consumption 14.5 W 15 W 7.5 WNoise, free blowing 41 dB(A) 38 dB(A) 32 dB(A)Bearing system Ball bearing Ball bearing Ball bearingNominal speed 2900 min-1 2600 min-1 2100 min-1Permis. ambient temp. -40 °C to +60 °C -40 °C to +60 °C -40 °C to +70 °CService life L10 at 40°C 43,500 h 43,500 h 43,500 hApprovals CE, VDE CE, VDE CE, VDEUse in fan unit: 03.027.004.1 03.027.001.1 02.111.181.903.027.005.1 03.027.002.1 05.010.307.103.027.014.1 03.027.011.103.027.015.1 03.027.012.103.027.300.103.027.301.103.027.302.103.027.310.103.027.311.103.027.312.102.111.180.905.010.306.101.113.430.001.113.431.001.243.428.103.028.110.81.122


Knürr CoolBlast ®Euro Mains Cable <strong>for</strong> DIN 49 440and French/Belgian standardEuro ConnectionCable– Mains plug CEE/VII - Euro socket IEC 320– Cable: H05VV-F 3G 1 mm 2– Mains plug: IEC 320 - Euro socket IEC 320– Cable: HO5VV-F 3G 1 mm2DOS00076■ Mains voltage250 VACDOS00519■ Mains voltage250 VAC■ Nominal current10 A■ Nominal current10 AL S n F1 F2 19” Safe Model Order no. UP2000 04.000.054.9 1 unit5000 04.000.050.9 1 unitL S n F1 F2 19” Safe Model Order no. UP900 04.000.051.9 1 unitDOS00077Euro Mains Cable <strong>for</strong> Swissstandard– Mains plug: Type 12 - Euro socket IEC 320– Cable: H05VV-F 3G 1 mm 2■ Mains voltage250 VAC■ Nominal current10 AL S n F1 F2 19” Safe Model Order no. UP2000 04.000.055.9 1 unitELM00137Door Contact Switch– On/off switch, 4 A, 230 V ~– Activation with door opening and closing■ Supply schedule1 door contact switch (not wired)1 mounting brackets<strong>Mounting</strong> materialW H S U h d kg Model Order no. UP01.110.722.9 1 unitEuro Mains Cable <strong>for</strong>British standard– Mains plug: Type BS 1363 - Euro socket IEC320– Cable: HO5VV-F 3G 1 mm2DOS00078■ Mains voltage250 VAC■ Nominal current10 AL S n F1 F2 19” Safe Model Order no. UP2000 04.000.056.9 1 unit1.123


Knürr Thermal ManagementFilter <strong>Fan</strong>– For specific use with hot spots– Also suitable <strong>for</strong> later mounting, quick andeasy– The filter mats provide high filtering-outproperties, are easily exchanged and can becleaned– The fans do not require maintenance andtheir value is especially emphasized by theirlong lifespan and low noise factor– Airflow: Blowing in the rack (pre-setting)– Can be used as blowing-out or sucking-in■ MaterialHeat-resistant ABS plastic, UL 94 V-0■ ColorRAL 7035 light gray■ ApprovalsCE Symbol■ Protection ratingIP 54LUF20057LUF80011LUF80012LUF20058LUF800040LxW D/t/x y/z kg Max. AF El. conn. P N N Life/40º Model Order no. UP150x150 71/120/5 125/131 0.812 57 m3/h 230V / 50/60Hz 20 W 43 dB(A) 2650/min 40,000 h Filter fan 03.026.501.1 1 unit150x150 90/120/5.7 177/185 1 90 m3/h 230V / 50/60Hz 20 W 43 dB(A) 2650/min 40,000 h Filter fan 03.026.502.1 1 unit150x150 113/172/6 223/230 1.690 240m3/h 230V / 50/60Hz 29 W 50 dB(A) 2800/min 40,000 h Filter fan 03.026.503.1 1 unit150x150 125/208/7 291/302 3.620 520m3/h 230V / 50/60Hz 67 W 63 dB(A) 2770/min 50,000 h Filter fan 03.026.504.1 1 unit150x150 24/5 125/131 0.140 Exit filter 03.026.511.1 1 unit204x204 20.5/5.7 177/185 0.275 Exit filter 03.026.512.1 1 unit250x250 25/6 233/230 0.440 Exit filter 03.026.513.1 1 unit325x325 26/7 291/302 0.780 Exit filter 03.026.514.1 1 unit150x150 Replacement filter mat 03.026.521.9 6 units204x204 Replacement filter mat 03.026.522.9 6 units250x250 Replacement filter mat 03.026.523.9 6 units325x325 Replacement filter mat 03.026.524.9 6 unitsDimensions in mm: W = Width U = standard height unitH = Height1 U = 44.45 mmD = Depth UP = unit of packagingh = installation height kg = weightd = useful depthL = length= Express itemConversion: 1 mm = 0.03937 inch1 kg = 2.2046 poundStandard Per<strong>for</strong>mance = SP n = Number of fansHigh Per<strong>for</strong>mance = HP W = Power consumption (W)Ultra High Per<strong>for</strong>mance = UP m 3 /h = Air volume flowP1 = Pressure increaseI nom = Nominal current (A)I max = Residual current (A)P = Power consumption (W)V = Voltage (400V = 3-phase)1.124


Knürr Thermal ManagementTemperature ModuleBracket <strong>for</strong>Temperature ModuleLUF00237a– For monitoring the inside temperature ofthe rack– Temperature display (+ 10°C... + 70°C)– Setting the alarm temperature via frontalpotentiometer– Optical alarm display (LED red)– Alarm signaling via floating switchingcontact (1 changeover contact 250 VAC /8 A)– Power supply 230 V / 50HzLUF00255– For non-standard installation oftemperature module, e.g. laterally on the19" extrusion■ Material/finishAluminum, 2 mm, polished■ Supply schedule1 bracket<strong>Mounting</strong> material■ MaterialPlastic■ ApprovalsCE Symbol in acc. with Low Voltage Directive73/23/EEC, EMC Directive 89/336/EEC■ How suppliedFlat-packed kitW H D LxW kg W n Model Order no. UP01.117.527.0 1 unitW H D LxW kg W n Model Order no. UPLUF00256■ Supply schedule1 temperature module1 temperature sensor (3 m)■ How suppliedAssembled, wired and tested01.117.525.1 1 unit19" Front Panel 1 U <strong>for</strong>Temperature Module– For installing the temperature module■ Material/finishSheet steel 1.5 mm, powder-coated■ ColorRAL 7035 light gray■ Supply schedule1 19" front panelW H D LxW kg W n Model Order no. UP01.117.526.1 1 unitLUF20000Thermostat– For controlling the inside temperature ofthe rack in conjunction with fan units andheating fans– Setting range: + 10°C ... + 60°C– Switching temperature difference(hysteresis) 2K– Contact type: 1 changeover contact– Sensor: Thermo-bimetal– Contact rating: 230 VAC/10 A (heating),5 A (cooling)– Interference suppression: in acc. with DIN55014■ MaterialPlastic■ Protection ratingIP 30■ ApprovalsCE Symbol in acc. with Low Voltage Directive73/23/EEC, EMC Directive 89/336/EEC■ Dimensions74 x 74 x 23 mm■ Supply schedule1 thermostat1 mounting bracket<strong>Mounting</strong> materialW H D LxW kg W n Model Order no. UP01.113.384.3 1 unit1.125