Register No. Function DescriptionR4146R4147R4148R4149Port 1 Communication ParametersRegisterTransmission Delay & ReceiveTime-out interval time Setting,while Port 1 being used as the master ofFUN151 or FUN150Message Frame Detection Time IntervalModem Interface Setting & Port0without checking of station number forFATEK's external communication protocolSet Baud Rate, Data bit… of Port 1Low Byte:Port 1 Receive Time-out interval time(Unit in 10mS)High Byte:Port 1 Transmission Delay(Unit in 10mS).While the communication port being used as the master orslave of Modbus RTU protocol, the system will give thedefault time interval to identify each packet of receivingmessage; except this, the user can set this time intervalthrough the high byte setting of R4148 and let M1956 be1, to avoid the overlap of different packet of messageframe.M1956=1, High Byte of R4148 is used to set the newmessage detection time interval for Port 1~Port 4 (Unitin mS).While the communication port being used to communicatewith the intelligent peripherals through FUN151instruction, if the communication protocol without the endof text to separate each packet of message frame, itneeds message detection time interval to identify thedifferent packet. High byte of R4148 is used for thissetting for Port 1~Port 4.(Unit in mS)• High Byte of R4149:=55H, Remote-Diagnosis/Remote-CPU-Linkby way of Port 1 through Modemconnection, it supports userprogram controlled dial up function=AAH, Remote diagnosis by way of Port 1through Modem connection, itsupports Passive receiving & Activedialing operation mode=Others, without above function• Low Byte of R4149:=1, Port 0 without checking of station numberfor FATEK's externalcommunication protocol (communicating withMMI/SCADA)=Others, Port 0 checks station number, it allowsmulti-drop network for data acquisition.R4150 Power on I/O service delay time setting • PLC is ready for I/O service after this delay time whilepower up. The unit is in 0.01S. The default value is 100.R4151 Circular 1mS time base timer • The content of R4151 will be increased by 1 every 1mS.It can be used for a more precise timing application.R4152 Low word of HSTA CV register HSTA is high speed timer in 0.1 mS resolutionR4153R4154High word of HSTA CV registerPV register of HSTAThe HSTA can act as 32-bit cyclic timer or fixed timeinterrupt timer2-15

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!