Register No. Function DescriptionR4046 Power up initialization mode selection of dataregisters that has been written into ROMPack.=5530H: Don’t initialize the addressed data registersbeen written into ROM Pack while power up=Others : initialize the addressed data registers beenwritten into ROM Pack while power upR4047 Communication protocol setting for Port1~Port4Set the FATEK or Modbus RTU communicationprotocolR4048 Transmission Delay & ReceiveTime-out interval time Setting,while Port 4 being used as the master ofFUN151 or FUN150Low Byte:Port 4 Receive Time-out interval time (Unitin 10mS)High Byte:Port 4 Transmission Delay(Unit in 10mS)R4049 CPU Status Indication =A55AH, Force CPU RUN=0, Normal Stop=1, Function(s) existed that CPU does not support=2, PLC ID not matched with Program ID=3, Ladder checksum error=4, System STACK error=5, Watch-Dog error=6, Immediate I/O over the CPU limitation=7, Syntax not OK=8, Qty of expansion I/O modules exceeds=9, Qty of expansion I/O points exceeds=10, CRC error of system FLASH ROMR4050 Port 0 Communication Parameters Register Set Baud Rate of Port 0R4051 ReservedR4052 Indicator while writing ROM PackR4053 ReservedR4054 Define the master station numberof the High-Speed CPU Link network(FUN151 Mode 3)If the master station number is 1,it can ignore thisregister.To set the master station number other than 1 should:Low Byte : Station numberHigh Byte: 55HR4055 PLC station number • If high byte is not equal 55H, R4055 will show thestation number of this PLC• If want to set PLC station number then R4055should set to:Low Byte : Station numberHigh Byte: 55HR4056High Byte :ReservedLow Byte: High speed pulse output frequencydynamic controlLow Byte: =5AH, can dynamically change the outputfrequency of High Speed Pulse OutputR4057 Power off counter The value will be increased by 1 while power upR4058Error station number while Port 2 in HighSpeed CPU LinkUsed by FUN151 Mode 3 of Port 22-10
Register No. Function DescriptionR4059Error code while Port 2 in High Speed CPULINK modeUsed by FUN151 Mode 3 of Port 2High byte Low ByteR4059 Err code Err count HError code: 0AH, No response01H, Framing Error02H, Over-Run Error04H, Parity Error08H, CRC ErrorR4060 Error code of PSO 0 The error codes are:1: Parameter 0 error2: Parameter 1 error3: Parameter 2 error4: Parameter 3 error5: Parameter 4 error7: Parameter 6 error8: Parameter 7 error9: Parameter 8 error10: Parameter 9 error30: Speed setting reference number error31: Speed value error32: Stroke setting reference number error33: Stroke value error34: Illegal positioning program35: Step over36: Step number exceeds 25537: Highest frequency error38: Idle frequency error39: Movement compensation value too large40: Movement value exceeds range41: DRVC instruction not allow ABS addressingR4061 Error code of PSO 1 Same as aboveR4062 Error code of PSO 2 Same as aboveR4063 Error code of PSO 3 Same as aboveR4064 PSO 0R4065R4066Being completed step number of positioningprogramPSO 1PSO 2R4067 PSO 3R4068│R4071Reserved2-11
- Page 6 and 7: Conventional Ladder DiagramPLC Ladd
- Page 8 and 9: Input processing (Reading thestatus
- Page 10 and 11: We must energize the coil of relay
- Page 12 and 13: Network: Network is a circuit repre
- Page 15 and 16: 1.5 The De-Composition of a Network
- Page 18 and 19: • When a single element or a seri
- Page 20 and 21: MEMO
- Page 22 and 23: 2.2 Digital and Register Allocation
- Page 24 and 25: Relay No. Function Description3. Pu
- Page 26 and 27: Relay No. Function DescriptionM1965
- Page 28 and 29: 2.4 Special Registers DetailsRegist
- Page 32 and 33: Register No. Function DescriptionR4
- Page 34 and 35: Register No. Function DescriptionR4
- Page 36 and 37: Register No. Function DescriptionR4
- Page 38 and 39: Register No. Function DescriptionD4
- Page 40 and 41: Instruction Operand Symbol Function
- Page 42 and 43: FUNNo.NameOperandDerivativeInstruct
- Page 44 and 45: FUNNo.NameOperandDerivativeinstruct
- Page 46 and 47: • Ramp Function InstructionsFUNNo
- Page 48 and 49: MEMO
- Page 50 and 51: ※For the relays marked with a ‘
- Page 52 and 53: FUN7 is the UDCTR function. While r
- Page 54 and 55: X0X1Node ANode BIncerseInversediffe
- Page 56 and 57: All input controls of the function
- Page 58 and 59: • The names and functions of the
- Page 60 and 61: 5.1.4 Functions Output (FO)The “F
- Page 62 and 63: Indirect addressing program example
- Page 64 and 65: 5.3.2 The Coding of Numeric Numbers
- Page 66 and 67: (2). 0.5 = (-1) 0 * 2 ( 01111110 )
- Page 68 and 69: While all FBs-PLC numerical operati
- Page 70 and 71: Basic Function InstructionT TIMER T
- Page 72 and 73: Basic Function InstructionT TIMER T
- Page 74 and 75: Basic Function InstructionCCOUNTER(
- Page 76 and 77: Basic Function InstructionSET D PSy
- Page 78 and 79: Basic Function InstructionRST D PSy
Register No. Function DescriptionR4059Error code while Port 2 in High Speed CPULINK modeUsed by FUN151 Mode 3 of Port 2High byte Low ByteR4059 Err code Err count HError code: 0AH, No response01H, Framing Error02H, Over-Run Error04H, Parity Error08H, CRC ErrorR4060 Error code of PSO 0 The error codes are:1: Parameter 0 error2: Parameter 1 error3: Parameter 2 error4: Parameter 3 error5: Parameter 4 error7: Parameter 6 error8: Parameter 7 error9: Parameter 8 error10: Parameter 9 error30: Speed setting reference number error31: Speed value error32: Stroke setting reference number error33: Stroke value error34: Illegal positioning program35: Step over36: Step number exceeds 25537: Highest frequency error38: Idle frequency error39: Movement compensation value too large40: Movement value exceeds range41: DRVC instruction not allow ABS addressingR4061 Error code of PSO 1 Same as aboveR4062 Error code of PSO 2 Same as aboveR4063 Error code of PSO 3 Same as aboveR4064 PSO 0R4065R4066Being completed step number of positioningprogramPSO 1PSO 2R4067 PSO 3R4068│R4071Reserved2-11