[Instruction] Contents
[Instruction] Contents [Instruction] Contents
〝H〞 indicates hexadecimal↓ ↑Y15↑Y0※ WX、WY、WM、WS can display one item only but eachpressing status is available.Note:1、Pressing can move the cursor up and down or switch between CV or PV.2、Pressing or can decrease or increase the monitored item number.3、For a monitored item value, input a new value directly and then presscontacts can be changed by pressing + .. The status of the4、Pressing + can change the means to display a value (either with decimal or hexadecimalsystem).2、 DOC monitoring ↑Contact status← DOC of T10← Current value ← Register DOC← ValueNote:1、Pressing + can switch the monitoring of ADR and DOC.2、The display switch between CV (current value) and PV of the timer (counter) can use .3、 or can be moved up or down to next monitored item with DOC.3、 Speed monitoring FUN keys(FUN KEY 0~9, totaling 10 keys)【Pressing keys】: + ( ~ ) Direct display of a monitored item set by the client.Note:1、Items to be monitored can be set from the following “FUN functions”.2、Items to be monitored can be displayed with general or DOC means.Appendix -4
1.5 FUN Functions1.5.1 In and out of FUN functions■ Enter FUN functionsPress + +1、 PASSWORD OPEN2、 PASSWORD CLOSE3、 PASSWORD SET4、 DEFINE FUN KEY(Password open)(Password blocked)(Password setting)(Self-define speed monitoring function key FUN KEY 0-9)Press5、 DEFINE ALARMADDRESS6、 DEFINE SOFTKEY(8-KEY)(Self-define start address of content for display at an alarm)(Self-define 8 special keys)**7、 DEFINE SOFTKEYMODE (8-KEY)8、 DEFINE SOFTKEY(16-KEY)9、 ENTER SOFTKEYMODE(16-KEY)(Enter into the modes of the 8 special keys)(Self-define 16 special keys)(Enter into the modes of the 16 special keys)○○○○○*10、 VOLUME11、 SET DAP NO.12、 MAX. DAP NO.ON NETWORK(1~16)13、 WRITE PROTECT14、 RF CARD MODE15、 RF CARDSTART ADDR.16、 ENABLEKEYS MAPPING(Adjust volume)(Set DAP number(s) at multi-link)(Set the max. DAP numbers on network (1-16) at multi-link)(Data write-in protection)(RF card mode selection)(Start address of a RF card number storage)(Corresponding special contacts of ENABLE keys)*:Indicates when multiple DAPs are connected, each DAP can be set respectively.○ : Indicates when multiple DAPs are connected, the information set by one of them is not available for use until PLC is reset.■ Exit of FUN functions to general information setter functions. Press + + Monitored items +Note:1、When several DAPs are connected, information can be stored to PLC (D2944~D3071) if one of the DAP is set inall the FUN functions (except item 11).2、After entering FUN 4~15, without password protection, all the FUN functions can be executed by only pressing. With password protection, it is required to pass it first before executing FUN functions.3、If it is password-protected, FB-DAP will be set in a password protection status at each beginning of operation.4、FUN items 1~9 can be entered with numeric keys directly and then go straight to that function.5、After executing a item of FUN functions, if execution of other items is required, press the three keys+ + again.Appendix -5
- Page 224 and 225: Advanced Function InstructionFUN141
- Page 226 and 227: Advanced Function InstructionFUN143
- Page 228 and 229: Advanced Function InstructionFUN146
- Page 230 and 231: Advanced Function InstructionFUN 15
- Page 232 and 233: Advanced Function InstructionFUN160
- Page 234 and 235: Advanced Function InstructionFUN201
- Page 236 and 237: Advanced Function InstructionFUN 20
- Page 238 and 239: Advanced Function InstructionFUN 20
- Page 240 and 241: Advanced Function InstructionFUN 20
- Page 242 and 243: Advance Function InstructionFUN 208
- Page 244 and 245: Advanced Function InstructionFUN 21
- Page 246 and 247: Advanced Function InstructionFUN 21
- Page 248 and 249: MEMO
- Page 250 and 251: 8.2 Basic Formation of Step Ladder
- Page 252 and 253: . Single CycleM1924X0• When step
- Page 254 and 255: ●STP Sxxx : S20≦Sxxx≦S999(Dis
- Page 256 and 257: 【Description】: 1. When ON, the
- Page 258 and 259: ●STPEND :(Displayed in WinProladd
- Page 260 and 261: Example 1WinProladderFP-07M1924STP
- Page 262 and 263: Example 3WinProladderFP-07M1924STP
- Page 264 and 265: WinProladderFP-07M1924STP S0X1X2X0S
- Page 266 and 267: WinProladderM1924TO S0X1STP S0SET Y
- Page 268 and 269: ●Pedestrian Crossing Lights Contr
- Page 270 and 271: 8.6 Syntax Check Error Codes for St
- Page 272 and 273: 1.1 Profile112798716外 徑 4ψ×4
- Page 276 and 277: 1.5.2 FUN function description• F
- Page 278 and 279: 【Example】Assume definition as R
- Page 280 and 281: • Locations and application of th
- Page 282 and 283: 1.7.2 The Information formats of me
〝H〞 indicates hexadecimal↓ ↑Y15↑Y0※ WX、WY、WM、WS can display one item only but eachpressing status is available.Note:1、Pressing can move the cursor up and down or switch between CV or PV.2、Pressing or can decrease or increase the monitored item number.3、For a monitored item value, input a new value directly and then presscontacts can be changed by pressing + .. The status of the4、Pressing + can change the means to display a value (either with decimal or hexadecimalsystem).2、 DOC monitoring ↑Contact status← DOC of T10← Current value ← Register DOC← ValueNote:1、Pressing + can switch the monitoring of ADR and DOC.2、The display switch between CV (current value) and PV of the timer (counter) can use .3、 or can be moved up or down to next monitored item with DOC.3、 Speed monitoring FUN keys(FUN KEY 0~9, totaling 10 keys)【Pressing keys】: + ( ~ ) Direct display of a monitored item set by the client.Note:1、Items to be monitored can be set from the following “FUN functions”.2、Items to be monitored can be displayed with general or DOC means.Appendix -4