• When a single element or a serial block is connected in parallel with a parallel block, ANDLD instruction can be omitted ifput the parallel block in front.X0X1X2X3 X4X3X2X4X0X1ORG X 0 ORG X 3AND X 1 AND X 4LD X 2 OR X 2LD X 3 AND X 0AND X 4 AND X 1ORLDANDLD• If the branch node of a branch circuit is directly connected to the output coil, this coil could be located on top of the branchline (first row) to reduce the code.X0Y0Y1Y1 X0 Y0OUT TR 0 OUT Y 1AND X 0 AND X 0OUT Y 0 OUT Y 0LD TR 0OUT Y 1• The diagram shown below indicates the TR relay and the ORLD instruction can be omitted.X0Y0X1X2Y0X1X2X0OUT TR0X3Y1X1X3Y1ORG X 0 ORG X 1LD X 1 AND X 2OUT TR 0 OR X 0AND X 2 OUT Y 0ORLD ORG X 1OUT Y 0 AND X 3LD TR 0 OUT Y 1AND X 3OUT Y 11-14