June 2003HydropacHydropacWaterside Control Fan Coil UnitsFor Horizontal and Vertical ApplicationsFeaturesFlush panel extra rigidconstruction.Low noise levels.Eleven speed transformer.Full acoustic and thermalinsulation.Various filter options.All types of controlsavailable, fitted and wired.Outputs available up to6.4kW cooling and 6.9kWheating.Horizontal Hydropac PHW173 IllustratedDesigned and Built in BritainPatent Nos. Pending


HydropacPHW230 and PHW170 SeriesHydropac (Series PHW)<strong>Actionair</strong> Hydropac horizontalceiling void mounted type fancoils are waterside control,suitable for operation againstmoderate duct resistances,using chilled water coolingmedium and low pressure hotwater heating medium.Temperature control is bymeans of modulating 4-portdiverting valves on heatingand cooling, operated bystand alone or BMScontroller with room or returnair temperature sensor.Designated ‘PHW’, the seriesconsists of standard 230mm(PHW230) deep and slimline170mm (PHW170) deepversions.Robust construction 1.6mmtop panel and fan deck, all otherpanels 1.2mm galvanisedsteel.Interchangeable spun steelspigots and insulatedblanking plates.High quality EBM Ziehlexternal rotor motor fans.Fully insulated withClass ‘O’ open cellthermal and acousticfoam.Quick installation with recessedreinforced slotted mountingpoints.2


HydropacDetail ConstructionEasy filter removal with threefilter options: EU3 Filter Media. EU2 Metal Mesh. Commissioning filter (EU2Metal Mesh + Media Filter.)High performance coils withvents and drains. Circuited toprovide full contra flow.Pipe support plate.Insulated removable powdercoated drain tray, withconnection options.Illuminated on/off switch with3 speed fan and fine adjustmentswitches. Giving 9 speeds onexterior of units.Enclosure incorporating 11speed transformer with 24 voltoutput for FCU controller.3


Hydropac PHW 230 SeriesPHW 230 SeriesWaterside control 230mm deep ceiling void mounted chassis unitThermal Performance Data11 °C min air off 14 °C min air offChW 6°C flow,11°C returnChW 10°C flow,14°C returnLPHW 82°C flow72°C returnModel Speed Airflow Sensible Total Sensible/Total Cooling Heating Fan Input N.R.Setting (I/s) Cooling Cooling (Watts) (Watts) (Watts) Guide*(Watts) (Watts)2 75 905 1040 730 1050 33 303 85 990 1125 790 1130 47 32PHW231 4 100 1120 1255 880 1240 57 355 115 1240 1385 980 1345 66 386 125 1325 1475 1050 1415 78 402 110 1530 1890 1180 2150 50 303 125 1710 2080 1300 2290 70 32PHW232 4 150 2020 2430 1520 2500 90 355 175 2320 2800 1730 2700 110 386 185 2400 2890 1780 2800 144 402 90 1310 1640 1010 1960 60 303 120 1620 2000 1240 2220 75 32PHW232X 4 160 2110 2540 1570 2500 114 355 200 2690 3240 1990 2900 125 386 230 3050 3720 2260 3200 160 402 175 2450 3020 1830 3200 110 303 200 2800 3460 2070 3400 140 32PHW233 4 240 3360 4150 2460 3800 180 355 280 3920 4850 2870 4100 220 386 305 4270 5270 3110 4400 270 402 170 2660 3460 1970 3810 110 303 210 3200 4160 2360 4200 140 32PHW234 4 255 3650 4950 2820 4610 220 355 300 4000 5740 3280 5010 275 386 330 4200 6050 3530 5300 370 402 195 2800 3400 2150 4110 165 303 235 3350 4050 2610 4410 200 32PHW234X 4 290 4000 4770 3180 4910 240 355 340 4300 4960 3680 5410 300 386 375 4500 5100 4010 5700 356 402 185 2650 3210 2000 4510 165 303 225 3100 3710 2400 4910 200 32PHW235 4 280 4000 4830 3010 5410 290 355 340 4800 5800 3640 5910 365 386 375 5300 6400 3920 6310 495 402 230 3300 4010 2550 4910 227 303 275 3900 4720 2990 5410 288 32PHW235X 4 340 4800 5800 3640 5910 364 355 405 5400 6370 4290 6510 440 386 445 5600 6450 4670 6910 556 40The Fan Coil selections are based on thefollowing entering air conditions:Cooling:Summer On-coil air 23 °C Dry Bulb,16 °C Wet Bulb.Max Coil Pd = 20kPaHeating:Winter On-coil air temperature20 °C Dry Bulb.Max Coil Pd = 10kPaGeneral: External Resistance 30Pa. Electrical Supply 230 Volts/ 1 phase /50 Hz.Please refer to our Fan Coil Technical Department for alternative conditions.* see page 7 for NR Predictor.4


Hydropac PHW 230 SeriesPHW 230 SeriesDimensionsModel Dim A Dim B Weights SpigotsPHW 231 380 350 25kg 1-4-7PHW 232/2X 730 700 35kg 1-2-6-7PHW 233 1080 1050 50kg 1-2-4-6-7PHW 234/4X 1430 1400 70kg 1-2-3-5-6-7PHW 235/5X 1780 1750 90kg 1-2-3-4-5-6-75


Hydropac PHW 170 SeriesPHW 170 SeriesWaterside control 170mm deep ceiling void mounted chassis unitThermal Performance Data11 °C min air off 14 °C min air offChW 6°C flow,11°C return ChW 10°C flow,14°C returnLPHW 82°C flow72°C returnModel Speed Airflow Sensible Total Sensible/Total Cooling Heating Fan Input N.R.Setting (I/s) Cooling Cooling (Watts) (Watts) (Watts) Guide*(Watts) (Watts)2 90 1192 1407 978 1982 40 303 105 1385 1602 1120 2187 50 32PHW172 4 120 1532 1786 1255 2357 62 355 135 1701 1673 1394 2525 74 386 155 1928 2225 1579 2742 89 402 145 1893 2225 1550 3081 80 303 170 2187 2257 1790 3390 101 32PHW173 4 185 2380 2751 1932 3355 133 355 205 2592 3011 2123 3772 160 386 235 2941 3403 2410 4092 189 402 155 2237 2738 1675 3655 80 303 180 2573 3136 1916 4026 101 32PHW174 4 195 2774 3374 2067 4246 133 355 215 3035 3680 2268 4519 160 386 245 3399 4092 2557 4861 189 402 200 2825 3427 2127 4740 113 303 230 3228 3905 2423 5191 143 32PHW175 4 245 3429 4145 2577 5415 187 355 265 3696 4481 2786 5706 224 386 290 4002 4808 3031 5997 267 40The Fan Coil selections are based on thefollowing entering air conditions:Cooling:Summer On-coil air 23 °C Dry Bulb,16 °C Wet Bulb.Max Coil Pd = 20kPaHeating:Winter On-coil air temperature20 °C Dry Bulb.Max Coil Pd = 10kPaGeneral: External Resistance 30Pa. Electrical Supply 230 Volts/ 1 phase /50 Hz.Please refer to our Fan Coil Technical Department for alternative conditions.* see page 7 for NR Predictor.DimensionsUnit Dim A Dim B Dim C Weight SPIGOT OPTIONSPHW 172 730 700 225 32kg 1-2-4-7-8PHW 173 1080 1050 267 45kg 1-2-3-6-7-8PHW 174 1430 1400 287 65kg 1-2-3-4-6-7-8PHW 175 1780 1750 300 85kg 1-2-3-4-5-6-7-86


HydropacPVW230 Series Detail ConstruHydropac (Series PVW)<strong>Actionair</strong> vertical chassisand cased wall mountedfan coils are waterside control,suitable for free-blow,applications or vertical ductedarrangements operating up to60 Pa external resistance,using chilled water coolingmedium and low pressure hotwater medium.Temperature control is bymeans of modulating 4-portdiverting valves on heatingand cooling.Designated PVW the seriesconsists of five models 230mmdeep, with six non-cased/casedvariations.Protected controlenclosure.Discharge spigotcan be vertical orhorizontal.Slide out filters.EBM Ziehl externalrotor motor fans.Condensate removalpump when used.Removable frontaccess.8


HydropacctionPVW 230 Cases Options andMounting ArrangementsOption 1. Low levelmounting with front angledgrille outlet.Option 2. Low levelmounting with front angledgrille outlet and front facegrille inlet.Option 3. High levelmounting as per option 2but with protection panelon underside .Option 4. High levelmounting with front grilleoutlet and undersidegrille inlet.9


Hydropac Series PVW 230PVW 230 Series* Notes on ‘NR’ predictions Case Dimensional Data‘NR’ predictions are based uponextensive acoustic independenttests and are intended as a guideto levels which can be expected,when measured at 2.0m.The following qualifications apply:-Units must be mounted correctly, usingfixing points provided onto a flat, solidsurface, such as concrete or brick wall insuch a way that they are not subjected toundue stress and are checked foraccuracy of horizontal levelling.Rooms of open plan or partitioned designshould be furnished, carpeted and haveno more than 20% glass area with nohighly reflective surfaces such as ceramictiles etc.Where a single unit is serving a room thedimensions should be based upon acooling load of 120w/sq.m e.g a unitgiving 1.2kW total cooling output shouldbe serving a room with a floor area of notless than 10sq.m. In an open plan areaunits should be mounted at a minimum of3m centres and no closer than 1.5m froma corner.Units installed in accordance with theabove should give the predicted N.R. levelwhen measured at a distance of 2.0mfrom any surrounding flat surface.For detailed acoustic data ofRadiated Sound Power Levels,please refer to Technical SalesOffice.Option 1 CaseOption 2 and 3 CaseOption 4 CaseUnit Dim A Dim B WeightPVW 231 815 310 35kgPVW 232 1065 660 50kgPVW 233 1415 1010 70kgPVW 234 1785 1360 95kgPVW 235 2115 1710 120kg11


<strong>Actionair</strong>www.actionair.co.ukAlso availableNEWEnvironpac EMC Motor Technology 40% Less Motor Energy 1/3 Less Fan Heat Constant VolumeNEWSystempac Fancoil, Ductwork and Diffuser Package Fast Track Delivery Fully Acoustically Tested Sample Design SelectionAeropac Airside Control Fancoil 230mm Deep Horizontal Mounted High Energy EfficiencyTechnical Support<strong>Actionair</strong> provide quality productsbacked by a dedicated teamcommitted to providing the verybest in customer service.Specialist response from the<strong>Actionair</strong> Sales Team, administrativeresponse from the ComputerisedSales Office and productmaintenance from the Team ofExperienced Service Engineers, whounderstand fully the needs of theindustry.<strong>Actionair</strong> ProductsFor information on ourcomprehensive range of Fire,Smoke and Air Control Dampers, aswell as Application, Technical andPricing Advice, please refer to the<strong>Actionair</strong> Sales Office.NOCOMPROMISEQuality SystemCertificate No 017Assessed to ISO 9001 : 2000<strong>Actionair</strong>, South Street, Whitstable, Kent CT5 3DU EnglandTel: (01227) 276100 Fax: (01227) 264262 International Code: +441227Email: sales@actionair.co.uk Website: www.actionair.co.ukThe information contained herein issubject to change without notice due tocontinuing research and development.PRODUCED BY GRAPHIC PARTNERSHIP 01227 280877Part of Ruskin Air Management Limited