Interface Specification Document6.3.1.16 Bathymetric Data Output Selection (bathy only)• DESCRIPTION:This message selects the output port for bathy data.• SYNTAX:*DOUT,N• PARAMETERS:N – Output selection parameter. 0 for RS-232 or 1 for Ethernet.• EXAMPLE:*DOUT,1This example sets processor unit to output bathy data on the Ethernet port.6.3.1.17 Maximum Ping Rate• DESCRIPTION:This message sets the maximum ping rate in pings per second.• SYNTAX:*DRAT,N• PARAMETERS:N – Max data pings goes from 10 to 400 (= 1.0 to 40.0 pings per second).• EXAMPLE:*DRAT,200This message sets processor to output a maximum of 20 pings per second.6.3.1.18 Filter Setting (bathy only)• DESCRIPTION:This message sets which filters should be used.• SYNTAX:*FILT,N• PARAMETERS:N – Filter selection.0 – No filter.1 – Range filter only.2 – Depth filter only.3 – Both filters.• EXAMPLE:*FILT,1This example sets processor to use the range filter only.6.3.1.19 Flip• DESCRIPTION:This message tells the 81-P processor box of the orientation for the head.• SYNTAX:*FLIP,N• PARAMETERS:N – Orientation value.0 – Projector forward/up.1 – Projector aft/down.• EXAMPLE:*FILP,0This message tells 81-P processor that the head is mounted with projector forward.______________________________________________________________________SeaBat <strong>8101</strong> Operator's Manual 6-11 (ISD Rev 1.23) Version 3.02