Interface Specification Document6.3.1.32 Pulse Width• DESCRIPTION:This message sets the pulse width in seconds.• SYNTAX:*PWID,N • PARAMETERS:N – Pulse width value in seconds.• EXAMPLE:*PWID,0.0017Sets transmit pulse-width to 0.0017 seconds.6.3.1.33 Range• DESCRIPTION:This message changes the range setting.• SYNTAX:*RANG,N • PARAMETERS:N – Range value..• EXAMPLE:*RANG,5This example sets the range setting to 5 m.6.3.1.34 Raw Output Beam Selection (raw output only)• DESCRIPTION:This message sets the first exported beam.• SYNTAX:*RAWB,N• PARAMETERS:N – First exported beam (0 to maximum number of beams – 1)• EXAMPLE:*RAWB,0This message sets the first exported beam to be 0 (first beam).6.3.1.35 Raw Output Mode Selection (raw output only)• DESCRIPTION:This message sets the raw output mode.• SYNTAX:*RAWM,N• PARAMETERS:N – Mode0 – No data exported.1 – 16 bits magnitude, 20 beams exported.2 – 16 bits magnitude and 16 bits phase, 10 beam exported.3 – 8 bits magnitude, 40 beams exported.• EXAMPLE:*RAWM,1This message sets the raw output mode to 1 where 16 bit magnitude data (20 beams)are being exported.______________________________________________________________________SeaBat <strong>8101</strong> Operator's Manual 6-16 (ISD Rev 1.23) Version 3.02