TM 5-<strong>6115</strong>-631-14&PFigure 4-6. Fire Extinguisher Bracket Replacement.b. Installation.(1) Position fire extinguisher bracket (4) on fender (5).(2) Insert four screws (1) down through bracket (4) and through fender (5).(3) Install one flat washer (2) and one nut (3) on each screw (l). Tighten hardware tosecure bracket (4).4-21. Leg Prop Assembly Servicing. Servicing of the leg prop assembly is limited to semiannuallubrication (paragraph 4-9, b.).Section IX. MAINTENANCE OF ELECTRICAL SYSTEM4-22. General. This section contains maintenance information on electrical components unique tothe power plant end item. For all other electrical system maintenance, refer to the applicablegenerator set and trailer manuals as follows:a. Generator Set Maintenance. For generator set maintenance procedures, refer to TM 5-<strong>6115</strong>-584-12.b. Trailer Maintenance. For trailer maintenance procedures, refer to TM 9-2330-213-14&P.4-23. Switch Box Testing. To isolate the source of an electrical system problem, perform continuitytests on the components of the switch box as described below. Refer to the schematic diagram insidethe switch box (shown in figure 4-7 or 4-8, as applicable) to locate and identify the test pointsindicated in these procedures.4-17