13.07.2015 Views

Data and information technology - OBO Bettermann

Data and information technology - OBO Bettermann

Data and information technology - OBO Bettermann

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Planning aid, general<strong>information</strong>BET − testing centre for lightning protection, electrical engineering <strong>and</strong>support systemsLightning current testBET with countless tasksIf only lightning current, environmental<strong>and</strong> electrical testing waspossible at BET up to now, theBET Test Centre is now a competentpartner for testing of cablesupport systems. This combinationhas made it necessary to revisethe meaning of the name. If BETpreviously stood for "BlitzschutzundEMV-Technologiezentrum"(Lightning protection <strong>and</strong> EMC<strong>technology</strong> centre), since 2009these letters have meant BET Testcentre for lightning protection,electrical engineering <strong>and</strong> supportsystems.Test generator for lightning currenttestsThe test generator, planned in1994 <strong>and</strong> built in 1996, allows theexecution of lightning current testsof up to 200 kA. The generatorwas planned <strong>and</strong> constructed inconjunction with the Soest TechnicalCollege. Due to the intensiveplanning <strong>and</strong> scientific consultationrequired in the construction of thetesting system, this system hasworked without fault for 12 years<strong>and</strong> still meets the current st<strong>and</strong>ardtesting requirements.The main load of the test generatoris generated by the testing ofproducts from the TBS productunit. Here, tests to accompany developmentare carried out on newdevelopments, modifications of existing<strong>OBO</strong> products <strong>and</strong> alsocomparison tests on competingproducts. These include lightningprotection components, surge protectiondevices <strong>and</strong> lightning currentarrestors. Tests of lightningprotection components are carriedout according to DIN EN 50164-1,those for spark gaps according toDIN EN 50164-3 <strong>and</strong> those forlightning <strong>and</strong> surge protection devicesaccording to DIN EN 61643-11. This is just a small portion ofthe testing st<strong>and</strong>ards used fortests in the BET Test Centre.02 TBS-Katalog_2010_Neuer_St<strong>and</strong> / en / 30/03/2010 (LLExport_00986)16 <strong>OBO</strong> TBS

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!