13.07.2015 Views

ECW-GF, ECW-GF-DP - Pentair Thermal Management

ECW-GF, ECW-GF-DP - Pentair Thermal Management

ECW-GF, ECW-GF-DP - Pentair Thermal Management

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ecw-gf, ecw-gf-dp<strong>ECW</strong>-<strong>GF</strong> ControllerDisplayMenuBattery connectionRemote display panel(<strong>ECW</strong>-<strong>GF</strong>-<strong>DP</strong> only)Thermistor terminalsAlarm terminals<strong>ECW</strong>-<strong>GF</strong> without wire cover Wire cover LidWall mountingholes (typical 4)Actual temp LEDSet point temp LEDNext, Up, DownHeating cablepower terminalsGround terminalIncoming powerterminalsMENUHold 3SecondsBatteryConnectorMenu Settings:Units (°F or °C)Set PointDead BandHigh Temp AlarmLow Temp AlarmRemote <strong>GF</strong> Panel<strong>ECW</strong>-<strong>GF</strong>Digital Controllerwith Ground-Fault ProtectionTEMPERATURENextHold for<strong>GF</strong> TESTUpDown<strong>GF</strong>ResetACTUALSETPOINTDisplay: Alarms and StatusGround-fault test modeGround-fault circuit failureGround-fault cable faultShorted or open sensorRemote panel comm failureHigh temp alarmLow temp alarmWARNINGShock HazardDo not remove cover while energizedNe pas enlever le couvert tant que lerégulateur est sous tension6.3 in(160 mm)Temperature<strong>ECW</strong>-<strong>GF</strong>Digital electronic controller with equipmentground-fault protectionType 4XInput: 100-277 Vac, 50/60 Hz, 30 AOutput: 100-277 Vac, 30 A80BJ Maximum Ambient: 140˚F (60˚C)Enclosed EnergyFor maintaining temperatures up to 200˚F (93˚C)<strong>Management</strong>Equipment in nonhazardous locations.Equipment Ground-Fault Protection: 30 mAUse only with Raychem, XL-Trace, RaySol and IceStop heating cablesand Pyrotenax MI heating cables.ActualSetpoint© 2013 <strong>Pentair</strong> <strong>Thermal</strong> <strong>Management</strong> LLCWWW.PENTAIRTHERMAL.COMH58407 07/13Stand-offsNote:Next button is used for ground-fault test.Down button is used for ground-fault reset.6.3 in(160 mm)GeneralApprovalsNonhazardous locationsSupply voltage100–277 Vac ±10% 50–60 HzCommon supply for controller and heat tracing circuitEnclosureProtectionMaterialEntriesRelative humidityAmbient installation and usagetemperatureNEMA 4XFiberglass reinforced polyester plastic1 x 3/4 in (19 mm) conduit entries for power1 x 1 in (25 mm) conduit entry for heating cable1 x 1/2 in (13 mm) conduit entry for RTD sensor0% to 90%, noncondensing–40°F to 140°F (–40°C to 60°C)ControlRelay typeControl rangeDeadbandAccuracyDouble-pole, mechanical32°F to 200°F (0°C to 93°C)Adjustable 2°F to 10°F (2°C to 6°C)±3°F (1.7°C) of set pointInput powerVoltageCurrent277 Vac nominal, 50/60 Hz maximum30 A maximumMonitoring and alarm outputTemperatureRTD failureAlarm relayLow alarm range: 20°F (–6°C) to set point minus deadband, or OFFHigh alarm range: Set point plus (Deadband +5°F (3°C)) to 230°F, or OFFShorted or open temperature sensorForm C: 2 A at 277 Vac, 2 A at 48 Vdc2 / 5EN-DigiTrace<strong>ECW</strong>Family-DS-H58338 11/13THERMAL MANAGEMENT SOLUTIONS

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!