Pipe Freeze Protectionand Flow Maintenance<strong>ECW</strong>-<strong>GF</strong>, <strong>ECW</strong>-<strong>GF</strong>-<strong>DP</strong>Digital electronic controllers and remote display panelFire Sprinkler SystemFreeze Protection<strong>ECW</strong>-<strong>GF</strong> with FTC-PSK pipe standand power connection kit<strong>ECW</strong>-<strong>GF</strong> using RayClic powerconnection kit<strong>ECW</strong>-<strong>GF</strong>-<strong>DP</strong> remote display panelavailable only with <strong>ECW</strong>-<strong>GF</strong><strong>ECW</strong>-<strong>GF</strong>-<strong>DP</strong><strong>ECW</strong>-<strong>GF</strong> using a separate junction boxProduct OverviewThe DigiTrace <strong>ECW</strong>-<strong>GF</strong> electronic controller providesaccurate temperature control with integrated 30-mAground-fault protection. The <strong>ECW</strong>-<strong>GF</strong> is ideal for pipe freezeprotection, flow maintenance, freezer frost heave, floorheating and snow melting applications.The <strong>ECW</strong>-<strong>GF</strong> is housed in a NEMA 4X enclosure designed tobe wall mounted or installed on a pipe with the optional RaychemFTC-PSK pipe stand kit.The controller includes a window and a digital display thatshows the measured temperature, set point temperatureand alarm conditions (temperature sensor failure, high orlow temperature and ground-fault) if detected.Alarm conditions can be indicated via a Form C dry contactconnected to a building management system. Status LEDsindicate whether the digital display is showing the set pointor actual temperature or if the controller is in an alarmstate.The <strong>ECW</strong>-<strong>GF</strong> can be programmed to maintain temperaturesup to 200°F (93°C), at voltages from 100 to 277 V, and iscapable of switching current up to 30 amperes.Programming the set point temperature, deadband, and thehigh and low alarm thresholds on the controllers is accomplishedusing the built-in digital display and push buttons. A9-V battery connector is supplied to allow programming thecontroller before the heating cable circuit power is provided.An optional remote display panel, the DigiTrace <strong>ECW</strong>-<strong>GF</strong>-<strong>DP</strong>,is available. This remote display provides remote alarmindication and ground-fault test and reset capability. The<strong>ECW</strong>-<strong>GF</strong>-<strong>DP</strong> can be installed indoors in a standard duplexbox located up to 328 ft (100 m) from the controller.Roof and GutterDe-IcingSurface SnowMelting – MISurface SnowMelting – ElectroMeltFreezer FrostHeave PreventionTHERMAL MANAGEMENT SOLUTIONS EN-DigiTrace<strong>ECW</strong>Family-DS-H58338 11/13The <strong>ECW</strong>-<strong>GF</strong> is supplied with a 25-foot thermistor for line,slab or ambient sensing temperature control.1 / 5Floor Heating Technical DataSheets


ecw-gf, ecw-gf-dp<strong>ECW</strong>-<strong>GF</strong> ControllerDisplayMenuBattery connectionRemote display panel(<strong>ECW</strong>-<strong>GF</strong>-<strong>DP</strong> only)Thermistor terminalsAlarm terminals<strong>ECW</strong>-<strong>GF</strong> without wire cover Wire cover LidWall mountingholes (typical 4)Actual temp LEDSet point temp LEDNext, Up, DownHeating cablepower terminalsGround terminalIncoming powerterminalsMENUHold 3SecondsBatteryConnectorMenu Settings:Units (°F or °C)Set PointDead BandHigh Temp AlarmLow Temp AlarmRemote <strong>GF</strong> Panel<strong>ECW</strong>-<strong>GF</strong>Digital Controllerwith Ground-Fault ProtectionTEMPERATURENextHold for<strong>GF</strong> TESTUpDown<strong>GF</strong>ResetACTUALSETPOINTDisplay: Alarms and StatusGround-fault test modeGround-fault circuit failureGround-fault cable faultShorted or open sensorRemote panel comm failureHigh temp alarmLow temp alarmWARNINGShock HazardDo not remove cover while energizedNe pas enlever le couvert tant que lerégulateur est sous tension6.3 in(160 mm)Temperature<strong>ECW</strong>-<strong>GF</strong>Digital electronic controller with equipmentground-fault protectionType 4XInput: 100-277 Vac, 50/60 Hz, 30 AOutput: 100-277 Vac, 30 A80BJ Maximum Ambient: 140˚F (60˚C)Enclosed EnergyFor maintaining temperatures up to 200˚F (93˚C)<strong>Management</strong>Equipment in nonhazardous locations.Equipment Ground-Fault Protection: 30 mAUse only with Raychem, XL-Trace, RaySol and IceStop heating cablesand Pyrotenax MI heating cables.ActualSetpoint© 2013 <strong>Pentair</strong> <strong>Thermal</strong> <strong>Management</strong> LLCWWW.PENTAIRTHERMAL.COMH58407 07/13Stand-offsNote:Next button is used for ground-fault test.Down button is used for ground-fault reset.6.3 in(160 mm)GeneralApprovalsNonhazardous locationsSupply voltage100–277 Vac ±10% 50–60 HzCommon supply for controller and heat tracing circuitEnclosureProtectionMaterialEntriesRelative humidityAmbient installation and usagetemperatureNEMA 4XFiberglass reinforced polyester plastic1 x 3/4 in (19 mm) conduit entries for power1 x 1 in (25 mm) conduit entry for heating cable1 x 1/2 in (13 mm) conduit entry for RTD sensor0% to 90%, noncondensing–40°F to 140°F (–40°C to 60°C)ControlRelay typeControl rangeDeadbandAccuracyDouble-pole, mechanical32°F to 200°F (0°C to 93°C)Adjustable 2°F to 10°F (2°C to 6°C)±3°F (1.7°C) of set pointInput powerVoltageCurrent277 Vac nominal, 50/60 Hz maximum30 A maximumMonitoring and alarm outputTemperatureRTD failureAlarm relayLow alarm range: 20°F (–6°C) to set point minus deadband, or OFFHigh alarm range: Set point plus (Deadband +5°F (3°C)) to 230°F, or OFFShorted or open temperature sensorForm C: 2 A at 277 Vac, 2 A at 48 Vdc2 / 5EN-DigiTrace<strong>ECW</strong>Family-DS-H58338 11/13THERMAL MANAGEMENT SOLUTIONS


Temperature Sensor (included)Input typeThermistor 10K ohm @25C Type Jecw-gf, ecw-gf-dpPipe Freeze Protectionand Flow MaintenanceGround-faultGround-fault protectionGround fault trip resetGround-fault testProgramming and SettingMethod30 mA fixedUnits °F or °CDigital displayLEDsMemoryStored parametersAlarm conditionsConnection TerminalsPower supply inputHeating cable outputGroundThermistorAlarmRemote display panelReset button, manualManual ground-fault circuitry test; automatic hourly circuitry testProgrammable at controller – Push buttons on front panelFour numeric display digits for parameter and error/alarm indicationIndicate actual and set point from display and alarm stateNonvolatile, restored after power lossParameters can be programmed without power supply (external battery) andparameters are stored in nonvolatile memory.Low/high temperature and thermistor failure (open or shorted)Ground-fault trip, ground-fault circuit failure and loss of power.Screw rising cage clamp, 18–6 AWGScrew rising cage clamp, 18–6 AWGScrew rising cage clamp, 18–6 AWGScrew rising cage clamp, 22–14 AWGScrew rising cage clamp, 22–14 AWGScrew rising cage clamp, 22–14 AWG<strong>ECW</strong>-<strong>GF</strong>-<strong>DP</strong> Remote Panel (for <strong>ECW</strong>-<strong>GF</strong> controller only)1.760 in. (44.7 mm)Fire Sprinkler SystemFreeze ProtectionRoof and GutterDe-IcingSurface SnowMelting – MISurface SnowMelting – ElectroMeltPower<strong>ECW</strong>-<strong>GF</strong>-<strong>DP</strong>Blinking = Communication errorGround-Fault ResetBlinking = Ground-fault tripor circuitry failureGround-Fault TestBlinking = Ground-faul test passBlinking alternately red and amber= Other alarm; check <strong>ECW</strong>-<strong>GF</strong>THERMAL MANAGEMENT SOLUTIONS EN-DigiTrace<strong>ECW</strong>Family-DS-H58338 11/134.110 in. (104.4 mm)3.806 in. (96.7 mm)3.275 in. (83.2 mm)3 / 5Freezer FrostHeave PreventionFloor Heating Technical DataSheets


ecw-gf, ecw-gf-dpgeneralApprovalsNonhazardous locationsEnvironmentAmbient operating temperatureHumidityIndoors, dry area32°F to 122°F (0°C to 50°C)90% noncondensingfeaturesLEDButtonsPowerConnection3 LEDs 1 green, 1 red, 1 amber2: Ground-fault reset, Ground-fault testPower provided from <strong>ECW</strong>-<strong>GF</strong> controller12 Vdc @ 100 mA8 position terminal block8 conductor 22 AWG shielded cable Alpha - Cat No. 1298C or equivalent328 ft (100 m) maximumOrdering detailsDescription Catalog number Part number Weight/lbsWall mounted digital electronic controller with ground fault <strong>ECW</strong>-<strong>GF</strong> P000000925 4.0Remote display panel for <strong>ECW</strong>-<strong>GF</strong> <strong>ECW</strong>-<strong>GF</strong>-<strong>DP</strong> P000000926 0.3Pipe mounting kit with power connection and end seal FTC-PSK P000000927 0.24 / 5EN-DigiTrace<strong>ECW</strong>Family-DS-H58338 11/13THERMAL MANAGEMENT SOLUTIONS


WWW.PENTAIRTHERMAL.COMNORTH AMERICATel: +1.800.545.6258Fax: +1.800.527.5703Tel: +1.650.216.1526Fax: +1.650.474.7711thermal.info@pentair.comEurope, Middle East, AfricaTel: +32.16.213.511Fax: +32.16.213.603thermal.info@pentair.comAsia PacificTel: +86.21.2412.1688Fax: +86.21.5426.2917cn.thermal.info@pentair.comLatin AmericaTel: +1.713.868.4800Fax: +1.713.868.2333thermal.info@pentair.com<strong>Pentair</strong> and DigiTrace are owned by <strong>Pentair</strong> or its global affiliates. All other trademarks are the property of their respective owners. <strong>Pentair</strong> reservesthe right to change specifications without prior notice.© 2012–2013 <strong>Pentair</strong>.THERMAL MANAGEMENT SOLUTIONS EN-DigiTrace<strong>ECW</strong>Family-DS-H58338 11/135 / 5