ST.150 - Stanton

ST.150 - Stanton ST.150 - Stanton

medias.audiofanzine.com
from medias.audiofanzine.com More from this publisher
13.07.2015 Views

SPECIFICATIONSTURNTABLE SECTIONStarting Torque:Motor:Platter:Pitch:Brake:More than 4.5kgf.com16pole, 3phase, brushless DC motor332mm dia. Aluminum diecast+/-8%,+/-25%,+/-50%Electronic BrakeTONE ARM SECTIONTone arm typeStatic balanced S -shaped tonearmstraight with detachable headshellEffective Arm Length230mmTracking Force Adjust Range 0-3gApplicable Cartridge Weight 13-18gFrequency Response20 - 20 KHzChannel SeparationMore than 15 dBChannel BalanceWithin 2.5dB at 1 KHzWow & Flutter:Less than 0.1% WRMS(JIS WTD) with 33 1/3rpmS/N ratio:More than 60dB (DIN-B)Needle Pressure range 2-5gGENERAL SPECIFICATIONSDimensions:450(W) x 353 (D) x 146 (H)mmWeight: 16.4KgPower supply:Single Voltage:AC 100V, 50Hz (For Japan)AC 110V, 60Hz (For Taiwan)AC 120V, 60Hz (For U.S.A.,Canada,Mexico)AC 220V, 50Hz (For United Arab Emirates,Chile,Argentina)AC 220V, 60Hz (For Philippines)AC 230V, 50Hz (For Europe,New Zealand,South Africa,Singapore,Israel)AC 240V, 50Hz (For Australia,U.K.)Power consumption:14W4

Ground lift OperationDue to the variety of power sources available to the DJ, Stanton has included aground lift switch to be used on the ST- 150/STR8-150 turntables. This will allowthe DJ to have the capability of changing the grounding scheme of the phonocartridge to avoid ground hum that may occur when using the turntable. The ST-150/STR8-150 Turntable has been designed to operate with third pin safety ground,and should always be used when available. N E V E R R E M O V E T H I R D P I NG R O U N D F R O M T H E P O W E R C O R D P R O V I D E D , I F N E C E S S A R Y ,USE THE APPROPRIATE ADAPTER FOR PLUGGING INTO OUTLETSWHICH DO NOT PROVIDE THIRD PIN GROUND TERMINALS.For best operation of the ground lift, the following rules should be appliedW h e n t h i r d p i n s a f e t y g r o u n d i s u s e d , set the ground lift switch to the liftposition. This position will isolate the cartridge ground from connection to earthground.When third pin safety ground is unavailable, set the ground lift switch to theconnected position. This will place the cartridge ground in connection with thechassis ground, but since third pin grounding is not used, the cartridge ground willnot be in connection with earth.5

Ground lift OperationDue to the variety of power sources available to the DJ, <strong>Stanton</strong> has included aground lift switch to be used on the ST- 150/STR8-150 turntables. This will allowthe DJ to have the capability of changing the grounding scheme of the phonocartridge to avoid ground hum that may occur when using the turntable. The ST-150/STR8-150 Turntable has been designed to operate with third pin safety ground,and should always be used when available. N E V E R R E M O V E T H I R D P I NG R O U N D F R O M T H E P O W E R C O R D P R O V I D E D , I F N E C E S S A R Y ,USE THE APPROPRIATE ADAPTER FOR PLUGGING INTO OUTLETSWHICH DO NOT PROVIDE THIRD PIN GROUND TERMINALS.For best operation of the ground lift, the following rules should be appliedW h e n t h i r d p i n s a f e t y g r o u n d i s u s e d , set the ground lift switch to the liftposition. This position will isolate the cartridge ground from connection to earthground.When third pin safety ground is unavailable, set the ground lift switch to theconnected position. This will place the cartridge ground in connection with thechassis ground, but since third pin grounding is not used, the cartridge ground willnot be in connection with earth.5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!