13.07.2015 Views

sider - Socomec

sider - Socomec

sider - Socomec

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Load break switches for power distributionSIDERAuxiliary contacts for pre-break and signalling - Right side operationNO/NC contactRating (A) Position AC ReferenceND 125 … ND 500 1 st 3999 0021ND 125 … ND 500 2 3999 0022630 … 1 600 1 st 2799 0011630 … 1 600 2 nd 2799 0012acces_047_a_2_catacces_056_a_1_catNC contactRating (A) Position AC ReferenceND 125 … ND 500 1 to 4 3999 0701NO contactRating (A) Position AC ReferenceND 125 … ND 500 1 to 4 3999 0702UsePre-break and signalling of positions 0 and I:- 1 to 2 NO/NC auxiliary contacts,- 1 to 4 NO or NC auxiliary contacts.Connection to the control circuitBy 6.35 mm fast-on terminal.CharacteristicsNO/NC AC: IP2.Electrical characteristics30 000 operations.Low level NO/NC auxiliary contactsRating (A) Position AC Reference630 … 1 600 1 2799 0111CharacteristicsOperating current Ie (A)Current 250 VAC 400 VAC 24 VDC 48 VDCRating (A)Contact typenominal(A) AC-13 AC-13 DC-13 DC-13ND 125 … ND 500 inverter NO/NC 16 3 12 2ND 125 … ND 500 NC 10 6 4 5 3ND 125 … ND 500 NO 10 6 4 5 3630 … 1 600 inverter NO/NC 16 12 8 14 6S type auxiliary contacts for signalisation - Front and right side operationUsePosition 0 and I signalling 1 to 4 NO+NCauxiliary contacts.Connection to the control circuitBy terminals with max. section 10 mm 2 .Electrical principleThe NO+NC S-type auxiliary contacts canbe configured as 2 NO or 2 NC.Electrical characteristics30 000 operations.acces_051_a_2_catNO+NC contactRating (A) Position AC ReferenceND 125 … ND 500 1 3999 0041ND 125 … ND 500 2 3999 0042ND 125 … ND 500 3 3999 0043ND 125 … ND 500 4 3999 0044CharacteristicsOperating current Ie (A)Current 250 VAC 400 VACRating (A)Contact type nominal (A) AC-13 AC-13ND 125 … ND 500 NO + NC 20 10 8Terminal shroudsUseTop or bottom protection against directcontact with terminals or connectionparts.AdvantagePerforations allowing remotethermographic inspection withoutremoval.acces_093_a_1_catRating (A) No. of poles Position ReferenceND 125 … ND 200 3 P top or bottom 3998 3016 (1)ND 125 … ND 200 4 P top or bottom 3998 4016 (2)ND 250 … ND 500 3 P top or bottom 3998 3025 (1)ND 250 … ND 500 4 P top or bottom 3998 4025 (2)(1) Reference composed of 3 pieces.(2) Reference composed of 4 pieces.SOCOMEC General Catalogue 2011-201261

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!