13.07.2015 Views

sider - Socomec

sider - Socomec

sider - Socomec

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

‹ SIDER - Accessories (continued)Alternative S type handle cover colorsUseFor single lever handles type S1, S2, S3 and double lever handle, type S4.Other colours: consult us.acces_198_a_1_catHandle colourTo be orderedin multiples of Handle ReferenceLight grey 50 Type S1, S2 1401 0001Dark grey 50 Type S1, S2 1401 0011Light grey 50 S4 type 1401 0031Dark grey 50 S4 type 1401 0041Shaft for external handleacces_202_a_1_x_catacces_143_b_1_catacces_144_b_1_catacces_203_a_1_x_catXYUseStandard lengths:Other lengths: consult us.- 80 mm,- 200 mm,- 320 mm,- 400 mm,- 500 mm.For front operationRating (A)DimensionX (mm)Shaft length(mm) Type ReferenceND 125 … ND 500 95 … 230 200 mm 10 x 10 1400 1020ND 125 … ND 500 95 … 350 320 mm 10 x 10 1400 1032ND 125 … ND 500 95 … 530 500 mm 10 x 10 1400 1050630 … 1 600 295 … 555 200 mm 15 x 12 1401 1520630 … 1 600 295 … 675 320 mm 15 x 12 1401 1532630 … 1 600 295 … 755 400 mm 15 x 12 1401 1540For side operationRating (A)DimensionY (mm)Shaft length(mm) Type ReferenceND 125 … ND 500 20 … 110 80 mm 10 x 10 includedND 125 … ND 500 20 … 230 200 mm 10 x 10 1400 1020630 … 1 600 98 … 258 200 mm 15 x 12 1401 1520Auxiliary contacts for pre-break and signalling - Front operationacces_047_a_2_catacces_056_a_1_catUsePre-break and signalling of positions 0 and I:- 1 to 2 NO/NC auxiliary contacts,- 1 to 4 NO or NC auxiliary contacts.- 1 to 4 NO+NC auxiliary contacts.Connection to the control circuitBy 6.35 mm fast-on terminal.CharacteristicsNO/NC AC: IP2.Electrical characteristics30 000 operations.NO/NC contactRating (A) Position AC ReferenceND 125 … ND 500 1 st 3999 0021 (1)ND 125 … ND 500 2 3999 0022 (1)630 … 1 600 1 st 2799 0001630 … 1 600 2 nd 2799 0002(1) For direct operation.NC contactRating (A) Position AC ReferenceND 125 … ND 500 1 to 4 3999 0701 (1)(1) For direct operation.NO contactRating (A) Position AC ReferenceND 125 … ND 500 1 to 4 3999 0702 (1)(1) For direct operation.NO+NC contactRating (A) Position AC Reference630 … 1 600 1 2799 0005Low level NO/NC auxiliary contactsRating (A) Position AC Reference630 … 1 600 1 2699 0101CharacteristicsOperating current Ie (A)Current 250 VAC 400 VAC 24 VDC 48 VDCRating (A)Contact type nominal (A) AC-13 AC-13 DC-13 DC-13ND 125 … ND 500 inverter NO/NC 16 3 12 2ND 125 … ND 500 NC 10 6 4 5 3ND 125 … ND 500 NO 10 6 4 5 3630 … 1 600 inverter NO/NC 16 12 8 14 6630 … 1 600 NO + NC 15 10 6 15 1260General Catalogue 2011-2012 SOCOMEC

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!