Signal converter for electromagnetic flowmeters
Signal converter for electromagnetic flowmeters Signal converter for electromagnetic flowmeters
3 PROFIBUS PAIFC 300For both replacements 1. and 2., there are 2 options how to deal with the GSDs. In order toprovide communication between "IFC300 with PROFIBUS MBP interface" and the PLC, you may -in principle – use the GSD of the "IFC090PA" ("KROHF401.GSD" or "YP01F401.GSD") and–alternatively - the GSD of the "IFC300 with PROFIBUS MBP interface" ("KR024501.GSD" or"YP024501.GSD").However, both sets of GSDs, when applied, do not provide the same level of functionality in thePLC. The available PROFIBUS functionality of the "IFC300 with PROFIBUS MBP interface" in thePLC as function of installed flow sensor and GSD used for integration into the PLC is as follows:Installed flow sensorIntegration into the PLC viaIFS…FLUX flow sensor(Option 1.)IFC090PA.GSDKROHF401.GSD"IFC090PA" profile 2 functionalityIFC300 with PROFIBUS MBPinterface GSDKR024501.GSDIf the GSDs of the "IFC090PA" ("KROHF401.GSD" or "YP01F401.GSD") are used…• The IFC090PA parameter set for the PLC control software will be maintained, i.e. there is noadaptation needed with reference to the replaced interface of the IFC300 with PROFIBUSMBP interface.• In this usage of the GSD the PA Profile 2.0 functionality is provided in the PLC for bothreplacements, i.e. it is not possible to reset the PA totalizer via the PLC.If the GSD of "IFC300 with PROFIBUS MBP interface” (KR024501.GSD orYP024501.GSD) is used…"IFC300 with PROFIBUS MBPinterface" functionality (some"IFC300 with PROFIBUS MBPinterface" self-test functions notavailable)OPTIFLUX flow sensor (Option 2.) "IFC090PA" profile 2 functionality "IFC300 with PROFIBUS MBPinterface" functionalityHow to deal with the PAparameter set in the PLC CtrlsoftwareThe "IFC090PA" parameter setfor the PLC Ctrl software can beused as existing in the PLCThe "IFC090PA" parameter setfor the Ctrl software has to beadapted with reference to theinterface of "IFC300 withPROFIBUS MBP interface"• The IFC090PA parameter set for the PLC control software has to be adapted with reference tothe IFC300 PROFIBUS MPB interface.• In this usage of the GSD the PA Profile 3.0 functionality is provided and all diagnostic featuresof the "IFC300 with PROFIBUS MBP interface" are being made available.24www.krohne.com02/2011 - 4001086601 - AD IFC 300 PROFIBUS R01 en
IFC 300APPLICATION PROFILE 44.1 Function blocksThe PROFIBUS MBP interface is based on the PROFIBUS PA Profile Version 3.0 and supports thefollowing blocks:• 1 physical block.This block contains the parameters defined in PA Profile 3.0.• 1 transducer block for electromagnetic flow devices.This block provides the parameters and functions defined in PA Profile 3.0.• 5 Analog Input (AI) function blocks.As default: Volume Flow / Mass Flow / Speed Flow / Coil Temperature / Conductivity.• 3 totalizer (TOT) function blocks.As default the first two totalizers will totalize volume and the third one will totalize mass.4.2 Data structure of function block output valuesThe data structure of function block outputs consists of 5 bytes: a 4 byte float value (Float Formataccording IEEE Standard 754 Short Real Number) followed by a 1 byte status value. If all 8function block outputs have been configured (see above), 40 bytes will be transmitted.4.2.1 Float valueExample of float formatByte n Byte n+1Bit7 Bit6 Bit7 Bit6VZ 2 7 2 6 2 5 2 4 2 3 2 2 2 1 2 0 2 -1 2 -2 2 -3 2 -4 2 -5 2 -6 2 -7ExponentMantissaByte n+2 Byte n+3Bit7Bit72 -8 2 -9 2 -10 2 -11 2 -12 2 -13 2 -14 2 -15 2 -16 2 -17 2 -18 2 -19 2 -20 2 -21 2 -22 2 -23MantissaMantissaExample (binary): 40 F0 00 00 (hex) = 0100 0000 1111 0000 0000 0000 0000 0000Formula:value = (-1) VZ * 2 (Exponent – 127) * (1 + Mantissa)value = (-1) 0 * 2 (129 – 127) * (1 + 2 -1 + 2 -2 + 2 -3 )value = 1 * 4 * (1 + 0.5 + 0.25 + 0.125)value = 7.502/2011 - 4001086601 - AD IFC 300 PROFIBUS R01 enwww.krohne.com25
- Page 1 and 2: IFC 300 Supplementary instructionsS
- Page 3 and 4: IFC 300CONTENTS5 Profibus settings
- Page 5 and 6: IFC 300PROFIBUS DP 22.1 Software hi
- Page 7 and 8: IFC 300PROFIBUS DP 22.3 Electrical
- Page 9 and 10: IFC 300PROFIBUS DP 22.4 Technical d
- Page 11 and 12: IFC 300PROFIBUS DP 22.5.4 Manufactu
- Page 13 and 14: IFC 300PROFIBUS DP 22.5.5 Differenc
- Page 15 and 16: IFC 300PROFIBUS PA 3Issued Signal c
- Page 17 and 18: IFC 300PROFIBUS PA 33.3 Electrical
- Page 19 and 20: IFC 300PROFIBUS PA 33.5 GSD files f
- Page 21 and 22: IFC 300PROFIBUS PA 3INFORMATION!Dur
- Page 23: IFC 300PROFIBUS PA 33.5.5 Using the
- Page 27 and 28: IFC 300APPLICATION PROFILE 4Status
- Page 29 and 30: IFC 300APPLICATION PROFILE 4Octet n
- Page 31 and 32: IFC 300APPLICATION PROFILE 4Octet n
- Page 33 and 34: IFC 300APPLICATION PROFILE 4DIAGNOS
- Page 35 and 36: IFC 300PROFIBUS SETTINGS 55.3 Menu
- Page 37 and 38: IFC 300PROFIBUS SETTINGS 5No. Funct
- Page 39 and 40: IFC 300NOTES 602/2011 - 4001086601
3 PROFIBUS PAIFC 300For both replacements 1. and 2., there are 2 options how to deal with the GSDs. In order toprovide communication between "IFC300 with PROFIBUS MBP interface" and the PLC, you may -in principle – use the GSD of the "IFC090PA" ("KROHF401.GSD" or "YP01F401.GSD") and–alternatively - the GSD of the "IFC300 with PROFIBUS MBP interface" ("KR024501.GSD" or"YP024501.GSD").However, both sets of GSDs, when applied, do not provide the same level of functionality in thePLC. The available PROFIBUS functionality of the "IFC300 with PROFIBUS MBP interface" in thePLC as function of installed flow sensor and GSD used <strong>for</strong> integration into the PLC is as follows:Installed flow sensorIntegration into the PLC viaIFS…FLUX flow sensor(Option 1.)IFC090PA.GSDKROHF401.GSD"IFC090PA" profile 2 functionalityIFC300 with PROFIBUS MBPinterface GSDKR024501.GSDIf the GSDs of the "IFC090PA" ("KROHF401.GSD" or "YP01F401.GSD") are used…• The IFC090PA parameter set <strong>for</strong> the PLC control software will be maintained, i.e. there is noadaptation needed with reference to the replaced interface of the IFC300 with PROFIBUSMBP interface.• In this usage of the GSD the PA Profile 2.0 functionality is provided in the PLC <strong>for</strong> bothreplacements, i.e. it is not possible to reset the PA totalizer via the PLC.If the GSD of "IFC300 with PROFIBUS MBP interface” (KR024501.GSD orYP024501.GSD) is used…"IFC300 with PROFIBUS MBPinterface" functionality (some"IFC300 with PROFIBUS MBPinterface" self-test functions notavailable)OPTIFLUX flow sensor (Option 2.) "IFC090PA" profile 2 functionality "IFC300 with PROFIBUS MBPinterface" functionalityHow to deal with the PAparameter set in the PLC CtrlsoftwareThe "IFC090PA" parameter set<strong>for</strong> the PLC Ctrl software can beused as existing in the PLCThe "IFC090PA" parameter set<strong>for</strong> the Ctrl software has to beadapted with reference to theinterface of "IFC300 withPROFIBUS MBP interface"• The IFC090PA parameter set <strong>for</strong> the PLC control software has to be adapted with reference tothe IFC300 PROFIBUS MPB interface.• In this usage of the GSD the PA Profile 3.0 functionality is provided and all diagnostic featuresof the "IFC300 with PROFIBUS MBP interface" are being made available.24www.krohne.com02/2011 - 4001086601 - AD IFC 300 PROFIBUS R01 en