Signal converter for electromagnetic flowmeters
Signal converter for electromagnetic flowmeters Signal converter for electromagnetic flowmeters
3 PROFIBUS PAIFC 300INFORMATION!Although the PROFIBUS MBP technology supports power supply via the PROFIBUS line the"signal converter PROFIBUS MBP interface" will operate only if the additional power supply forthe device is connected / available.For a detailed description please check the signal converter handbook. Refer also to thePROFIBUS PA user and installation guideline (Version 2.2, February 2003 PNO order no. 2.092).3.4 Technical dataHardwareTypeConnectionBase currentFDEFault currentStarting currentEx approvalPROFIBUS RS485 interface according to IEC 61158-2 with31.25 kbits/s; voltage modeIndependent of polarity at electrical connection10.5 mAYes, separate fault disconnection electronics provided (FDE = FaultDisconnection Electronics)6 mA (fault current = max. continuous current – base current)
IFC 300PROFIBUS PA 33.5 GSD files for the data transferA PROFIBUS GSD ZIP file (e.g. GSD-31777813.zip; including both all GSD files and additional datafiles) you can get on a CD ROM or can be downloaded from the internet. The GSD file containsinformation that will be needed for project planning of the PROFIBUS communication network.The relevant data files (e.g. _ _ _ _ .bmp / _ _ _ _ .dib) must be loaded into the bus configurationsystem/master system before start-up of the bus system.3.5.1 Cyclic data exchangeDuring network configuration the user has to define which function block outputs of the signalconverter should be transferred cyclically to the master. Network configuration will be doneusing one of the GSD files described before. The order of transmission of a function block alwaysremains the same even if a function block is defined as an "Empty" block (if so, no function blockoutput data will be sent to the master and all function block outputs following the empty blockwill move up one position).3.5.2 Ident.-No. supportedThe signal converter with PROFIBUS MBP interface is based on PROFIBUS PA Profile V 3.0. Thedevice supports three Ident-No.:• Ident-No. "4501hex" belongs to the GSD file KR024501.GSD and YP024501.GSD and includesthe complete functionality of the electromagnetic flowmeter.• The application of the manufacturer independent Ident-No. "9740hex" (GSD file"PA039740.GSD") provides interchangeability of devices, i.e. an exchange of electromagneticflowmeters of different vendors.• Ident-No. "F401hex"For detailed information refer to Signal converter IFC 300 PROFIBUS PA with MBP interfaceas replacement for older signal converter IFC 090 PA on page 23.Please follow the instructions in the manual of the host supplier when installing the GSD File youneed and the additional files (_ _ _ _ .bmp and _ _ _ _ .dib) into the PLC.INFORMATION!If separated by the bus configuration system the device entry of the PROFIBUS MBP interfacewith PA Profile 3.0 will be located within the slave family PROFIBUS PA.02/2011 - 4001086601 - AD IFC 300 PROFIBUS R01 enwww.krohne.com19
- Page 1 and 2: IFC 300 Supplementary instructionsS
- Page 3 and 4: IFC 300CONTENTS5 Profibus settings
- Page 5 and 6: IFC 300PROFIBUS DP 22.1 Software hi
- Page 7 and 8: IFC 300PROFIBUS DP 22.3 Electrical
- Page 9 and 10: IFC 300PROFIBUS DP 22.4 Technical d
- Page 11 and 12: IFC 300PROFIBUS DP 22.5.4 Manufactu
- Page 13 and 14: IFC 300PROFIBUS DP 22.5.5 Differenc
- Page 15 and 16: IFC 300PROFIBUS PA 3Issued Signal c
- Page 17: IFC 300PROFIBUS PA 33.3 Electrical
- Page 21 and 22: IFC 300PROFIBUS PA 3INFORMATION!Dur
- Page 23 and 24: IFC 300PROFIBUS PA 33.5.5 Using the
- Page 25 and 26: IFC 300APPLICATION PROFILE 44.1 Fun
- Page 27 and 28: IFC 300APPLICATION PROFILE 4Status
- Page 29 and 30: IFC 300APPLICATION PROFILE 4Octet n
- Page 31 and 32: IFC 300APPLICATION PROFILE 4Octet n
- Page 33 and 34: IFC 300APPLICATION PROFILE 4DIAGNOS
- Page 35 and 36: IFC 300PROFIBUS SETTINGS 55.3 Menu
- Page 37 and 38: IFC 300PROFIBUS SETTINGS 5No. Funct
- Page 39 and 40: IFC 300NOTES 602/2011 - 4001086601
3 PROFIBUS PAIFC 300INFORMATION!Although the PROFIBUS MBP technology supports power supply via the PROFIBUS line the"signal <strong>converter</strong> PROFIBUS MBP interface" will operate only if the additional power supply <strong>for</strong>the device is connected / available.For a detailed description please check the signal <strong>converter</strong> handbook. Refer also to thePROFIBUS PA user and installation guideline (Version 2.2, February 2003 PNO order no. 2.092).3.4 Technical dataHardwareTypeConnectionBase currentFDEFault currentStarting currentEx approvalPROFIBUS RS485 interface according to IEC 61158-2 with31.25 kbits/s; voltage modeIndependent of polarity at electrical connection10.5 mAYes, separate fault disconnection electronics provided (FDE = FaultDisconnection Electronics)6 mA (fault current = max. continuous current – base current)