2 PROFIBUS DPIFC 300Definition of totalizer functionsTotalSetTot + TotalModeTot + TotalSetTot + ModeTot + TotalSetTotModeTotSetTot + ModeTotcyclic transfer of the totalizer value with status to the mastercyclic transfer of the totalizer value with status to the master + cycliccontrol data from master to the device via the parameter SetTotcyclic transfer of the totalizer value with status to the master + cycliccontrol data from master to the device via the parameter ModeTotcyclic transfer of the totalizer value with status to the master + cycliccontrol data from master to the device via the parameters SetTot andModeTot (in the given order)cyclic control data from master to the device via the parameterSetTotcyclic control data from master to the device via the parameterModeTotcyclic control data from master to the device via the parametersSetTot and ModeTot (in the given order)Both, the Byte SetTot and ModeTot are cyclically sent from the master to the device if these bytesare inserted as output data via the PLC configurator. The meaning of these control bytes are asfollows:Function of control bytesSetTotSetTot = 0SetTot = 1SetTot = 2SetTot > 2ModeTotModeTot = 0ModeTot = 1ModeTot = 2ModeTot = 3ModeTot = 248ModeTot = 249Totalizer is totalizing.Totalizer will be reset to 0 and stays at 0 until SetTot is switched backagain to 0. If the value of SetTot changes from "1" to "0" the totalizerstarts counting from 0.Totalizer is set to the value defined by PresetTot. PresetTot can bewritten via an acyclic master (totalizer in block 2 = Slot 2 Index 32;totalizer in block 3 = Slot 3 Index 32; totalizer in block 4 = Slot 4 Index32). If the value of SetTot changes from "2" to "0" the totalizer startscounting from the current value defined by PresetTot.Not allowed. Value is ignored; totalizer remains in its last validsetting.Totalizer totalizes positive and negative values.Totalizes only positive values.Totalizes only negative values.Totalizer is stopped, no totalization will be done.Totalizes all values as positive, negative values will be multiplied with-1.0.Totalizes all values as negative, positive values will be multiplied with-1.0.All other values of ModeTot not allowed. Value is ignored; totalizer remains in its last validsetting.The standard block configuration may be changed by the customer but using the default settingsis highly recommended. If the standard block configuration should be changed by the customeran acyclic master tool or the device display menu must be used to change the "channelparameter" value of the block which should be connected to another transducer output value.12www.krohne.com02/2011 - 4001086601 - AD IFC 300 PROFIBUS R01 en

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!