SV-EMS-220 Installation and ConfigurationPinEMS 25-pin Thermocouple Sensor (with <strong>Dynon</strong> part number ifHarness Wire Colorapplicable)1 Open N/A2 Open N/A3 Open N/A4 Open N/A5 Open N/A6 Red CHT 4 (J-type thermocouple, 100404-000*)7 Red EGT 4 (K-type thermocouple, 100405-000)8 Red CHT 39 Red EGT 310 Red CHT 211 Red EGT 212 Red CHT 113 Red EGT 114 Open N/A15 Open N/A16 Open N/A17 Open N/A18 White CHT 419 Yellow EGT 420 White CHT 321 Yellow EGT 322 White CHT 223 Yellow EGT 224 White CHT 125 Yellow EGT 1Table 26–Example Jabiru 2200 25-pin Connector Sensor Map* Note that J-type and K-type thermocouples apply to all CHTs or EGTs, respectively. They arenot repeated in the table for brevity’s sake.<strong>SkyView</strong> System Installation Guide - Revision J 7-19