SkyView - Dynon Avionics
SkyView - Dynon Avionics SkyView - Dynon Avionics
SV-ADAHRS-20X Installation and ConfigurationFigure 19 is a high-level overview of a suggested and installation and configuration procedurefor the SV-ADAHRS-20X.Choose alocation based onLocationRequirementsSectionPrepare thelocationInstall SkyViewnetwork cablingInstall AOA/PitotprobeReferenceAccessoryInstallation andConfigurationChapterInstall static port(not covered inthis guide)Install pneumaticplumbingInstall OAT probeand wiringInstall ADAHRSmodule withelectrical andpneumaticconnectionsConfigureSkyView Network*ConfigureADAHRS-relatedsettings onSkyView display*Perform magneticcalibrationPerform AOAcalibration*Assumes SV-D700 or SV-D1000 is properly installed and working.Figure 19–Suggested SV-ADAHRS-20X Installation Procedure5-2 SkyView System Installation Guide - Revision J
SV-ADAHRS-20X Installation and ConfigurationPhysical InstallationAs previously mentioned in the System Planning Section, there are no module-tomoduleproximity requirements when installing multiple SV-ADAHRS-20X modulesin an aircraft. For example, one SV-ADAHRS-20X may be installed on top ofanother SV-ADAHRS-20X module. Other installation location requirements stillapply.The diagram below shows the important mounting dimensions of the ADAHRS module withelectronic and pneumatic connections. Note that the figure applies to both the SV-ADAHRS-200and SV-ADAHRS-201 modules.OAT ConnectorFigure 20–SV-ADAHRS-20X Mounting Dimensions with Electronic and Pneumatic ConnectionsAdditional mounting location, orientation, and other installation requirements are described inthe System Planning section earlier in this manual. Please review this section when physicallyinstalling your with SV-ADAHRS-20X module(s).An ADAHRS module should be mounted within one degree of parallel to all three aircraft axes,with the pneumatic fittings facing toward the front of the aircraft. The module’s mounting tabsSkyView System Installation Guide - Revision J 5-3
- Page 16 and 17: IntroductionAbout this GuideIn the
- Page 18 and 19: System PlanningTable 4 contains phy
- Page 20 and 21: System PlanningSV-ADAHRS-200 and SV
- Page 22 and 23: System PlanningThere are no module-
- Page 24 and 25: System PlanningServos (SV32, SV42,
- Page 26 and 27: System Planningon any one of them.
- Page 28 and 29: System PlanningFigure 5-SkyView Sys
- Page 30 and 31: System PlanningHSI RequirementsThe
- Page 32 and 33: Basic SkyView Display OperationDisp
- Page 34 and 35: Basic SkyView Display OperationA bu
- Page 36: Basic SkyView Display OperationBasi
- Page 41 and 42: Basic SkyView Display OperationGPS
- Page 43: Basic SkyView Display OperationServ
- Page 46 and 47: SV-D700 / SV-D1000 Installation and
- Page 48 and 49: SV-D700 / SV-D1000 Installation and
- Page 50 and 51: SV-D700 / SV-D1000 Installation and
- Page 52 and 53: SV-D700 / SV-D1000 Installation and
- Page 54 and 55: SV-D700 / SV-D1000 Installation and
- Page 56 and 57: SV-D700 / SV-D1000 Installation and
- Page 58 and 59: SV-D700 / SV-D1000 Installation and
- Page 60 and 61: SV-D700 / SV-D1000 Installation and
- Page 62 and 63: SV-D700 / SV-D1000 Installation and
- Page 64 and 65: SV-D700 / SV-D1000 Installation and
- Page 68 and 69: SV-ADAHRS-20X Installation and Conf
- Page 71 and 72: SV-ADAHRS-20X Installation and Conf
- Page 73: SV-ADAHRS-20X Installation and Conf
- Page 76 and 77: SV-ADAHRS-20X Installation and Conf
- Page 78 and 79: SV-ADAHRS-20X Installation and Conf
- Page 81 and 82: 7. SV-EMS-220 Installation and Conf
- Page 83 and 84: SkyView Network ConnectionSV-EMS-22
- Page 85 and 86: SV-EMS-220 Installation and Configu
- Page 87 and 88: SV-EMS-220 Installation and Configu
- Page 89 and 90: SV-EMS-220 Installation and Configu
- Page 91 and 92: SV-EMS-220 Installation and Configu
- Page 93 and 94: SV-EMS-220 Installation and Configu
- Page 95 and 96: SV-EMS-220 Installation and Configu
- Page 97 and 98: SV-EMS-220 Installation and Configu
- Page 99 and 100: SV-EMS-220 Installation and Configu
- Page 101 and 102: SV-EMS-220 Installation and Configu
- Page 103 and 104: SV-EMS-220 Installation and Configu
- Page 105 and 106: Tools and Equipment RequiredSV-EMS-
- Page 107 and 108: SV-EMS-220 Installation and Configu
- Page 109 and 110: Note that you may need access to th
- Page 111 and 112: Fuel Pressure SensorSV-EMS-220 Inst
- Page 113 and 114: SV-EMS-220 Installation and Configu
- Page 115 and 116: SV-EMS-220 Installation and Configu
SV-ADAHRS-20X Installation and ConfigurationPhysical InstallationAs previously mentioned in the System Planning Section, there are no module-tomoduleproximity requirements when installing multiple SV-ADAHRS-20X modulesin an aircraft. For example, one SV-ADAHRS-20X may be installed on top ofanother SV-ADAHRS-20X module. Other installation location requirements stillapply.The diagram below shows the important mounting dimensions of the ADAHRS module withelectronic and pneumatic connections. Note that the figure applies to both the SV-ADAHRS-200and SV-ADAHRS-201 modules.OAT ConnectorFigure 20–SV-ADAHRS-20X Mounting Dimensions with Electronic and Pneumatic ConnectionsAdditional mounting location, orientation, and other installation requirements are described inthe System Planning section earlier in this manual. Please review this section when physicallyinstalling your with SV-ADAHRS-20X module(s).An ADAHRS module should be mounted within one degree of parallel to all three aircraft axes,with the pneumatic fittings facing toward the front of the aircraft. The module’s mounting tabs<strong>SkyView</strong> System Installation Guide - Revision J 5-3