Appendix E: Serial Data OutputParameterStartCharacterPositionNumCharsRange ofvalues /UnitsExample/NotesChecksum 71 2 00 to FF1 byte sum of all 70 precedingbytes in hexCR/LF 73 2 0x0D,0x0A Carriage Return, LinefeedTable 61 – <strong>SkyView</strong> ADAHRS Serial Data Output FormatNote: If the value of any field starting in position 12 up to position 71 is either invalid orunknown, then an 'X' is output for each character in the field instead of a value.As an example, the following is one line of DYNON ADAHRS serial output data:!1122260511+890-05262380930+09843-015-01+1002+000+381171249+1491121699A719-4 <strong>SkyView</strong> System Installation Guide - Revision J