SkyView - Dynon Avionics
SkyView - Dynon Avionics SkyView - Dynon Avionics
Appendix C: Wiring and Electrical ConnectionsD-subminiature Crimp Contacts and ToolsD-subminiature crimp contacts can be obtained from a variety of sources. Dynon recommendsthe use of the following Mil Spec types in avionics applications.Gender Mil Spec # Wire AWGFemale/Socket M39029/63-36820, 22, 24Male/Pin M39029/64-369Table 50–Recommended D-subminiature Crimp PinsUse a high quality 4-way indentation contact crimper when working the Mil Spec contacts inTable 50. Paladin Tools P/N 1440 (for 20 to 26 AWG wire) is an example of such a contactcrimper tool.Homemade Wire Harness ConsiderationsEach SkyView display includes its own wire harness (SV-HARNESS-D37) for connection to power,serial ports, USB, the external battery, and other connections. We recommend that you use thisharness for display installations instead of building your own.Here are some considerations if you build your own SkyView network wire harnesses.Wire InsulationWe recommend that all wire harness wires that are installed in aircraft utilize Tefzel® insulation.Twisted PairsSkyView networks utilize two data wire pairs for communication between devices. This guiderefers to these pairs as Data 1 and Data 2 and each have an A and a B wire. These pairs shouldhave 8 to 10 twists per foot over their entire length.Heat Shrink Bundling and Strain ReliefAll wires should be bundled together with heat shrink and then strain relieved when exiting theconnector shell or hood.SV-BAT-320 ConnectionTo connect a homemade harness to an SV-BAT-320, the following specifications must befollowed closely for the SV-BAT-320 to charge and work correctly:Connector:Pins:Wire:Molex Micro-Fit P/N 43640-0301 (Digi-Key P/N WM1856-ND)Molex Micro-Fit P/N 43031-0007 (Digi-Key P/N WM1841-ND)22 AWG Tefzel, NO MORE THAN 24” LONG; red w/yellow: M22759/16-22-24;black: M22759/16-22-017-2 SkyView System Installation Guide - Revision J
` Appendix C: Wiring and Electrical ConnectionsOAT ConnectionFunctionSkyView DB37 MolexConnector Pin Connector PinPower 2 3Ground 23 1Table 51 - SV-BAT-320 WiringFor customers that are converting from other Dynon products, you can use your installed OATwith the addition of the connector below. Both 100433-000 and 100433-001 are compatible.The OAT wiring can be extended as required. If you have 100433-001, ignore the red wire andconnect the yellow and blue wires to the connector below. The OAT is non-polarized; eitherwire can connect to either pin.Connector:Pins:Wire:Molex Micro-Fit P/N 43645-0200 (Digi-Key P/N WM1845-ND)Molex Micro-Fit P/N 43030-0007 (Digi-Key P/N WM1837-ND)22 AWG TefzelSkyView Equipment Electrical ConnectionsA SkyView display (SV-D700 and SV-D1000) has six connectors on the back of the unit asillustrated in Figure 84:One male DB37 for connection to the SkyView Display Harness (SV-HARNESS-D37)Two male DB9 SkyView network connectorsTwo Standard 4-pin USB 2.0 jacks for use with USB Series A plugs. Note that there is alsoa USB port on the SV-HARNESS-D37 for convenience.One standard 8-pin RJ45 connector for use with twisted pair category 5 Ethernet cableSkyView System Installation Guide - Revision J 17-3
- Page 181 and 182: Serial GPS Position Input (Future U
- Page 183 and 184: SV-XPNDR-26X Installation, Configur
- Page 185 and 186: SV-XPNDR-26X Installation, Configur
- Page 187 and 188: Altitude Encoder CalibrationSV-XPND
- Page 189 and 190: 12. SV-ARINC-429 Installation and C
- Page 191 and 192: SV-ARINC-429 Installation and Confi
- Page 193 and 194: ARINC Device ConnectionsSV-ARINC-42
- Page 195 and 196: SV-ARINC-429 Installation and Confi
- Page 197: SV-ARINC-429 Installation and Confi
- Page 200 and 201: SV-ARINC-429 Installation and Confi
- Page 202 and 203: SV-ARINC-429 Installation and Confi
- Page 204 and 205: Accessory Installation and Configur
- Page 206 and 207: Accessory Installation and Configur
- Page 208 and 209: Accessory Installation and Configur
- Page 210 and 211: Accessory Installation and Configur
- Page 212 and 213: Accessory Installation and Configur
- Page 214 and 215: Accessory Installation and Configur
- Page 217 and 218: 15. Appendix A: Maintenance and Tro
- Page 219 and 220: Appendix A: Maintenance and Trouble
- Page 221 and 222: Display Input VoltageThe display's
- Page 223 and 224: Appendix A: Maintenance and Trouble
- Page 225: Appendix A: Maintenance and Trouble
- Page 228 and 229: Appendix B: SpecificationsSkyView C
- Page 230 and 231: Appendix B: SpecificationsSV-XPNDR-
- Page 234 and 235: Appendix C: Wiring and Electrical C
- Page 236 and 237: Appendix C: Wiring and Electrical C
- Page 238 and 239: Appendix C: Wiring and Electrical C
- Page 240 and 241: Appendix C: Wiring and Electrical C
- Page 242 and 243: Appendix C: Wiring and Electrical C
- Page 244 and 245: Appendix C: Wiring and Electrical C
- Page 246 and 247: Appendix C: Wiring and Electrical C
- Page 249 and 250: 18. Appendix D: SV-EMS-220 Sensor I
- Page 251 and 252: 19. Appendix E: Serial Data OutputA
- Page 253 and 254: ` Appendix E: Serial Data OutputPar
- Page 255 and 256: ` Appendix E: Serial Data OutputDYN
- Page 257 and 258: ` Appendix E: Serial Data OutputPar
- Page 259 and 260: ` Appendix E: Serial Data OutputPar
- Page 261 and 262: ` Appendix E: Serial Data OutputPar
- Page 263 and 264: ` Appendix E: Serial Data Output!11
Appendix C: Wiring and Electrical ConnectionsD-subminiature Crimp Contacts and ToolsD-subminiature crimp contacts can be obtained from a variety of sources. <strong>Dynon</strong> recommendsthe use of the following Mil Spec types in avionics applications.Gender Mil Spec # Wire AWGFemale/Socket M39029/63-36820, 22, 24Male/Pin M39029/64-369Table 50–Recommended D-subminiature Crimp PinsUse a high quality 4-way indentation contact crimper when working the Mil Spec contacts inTable 50. Paladin Tools P/N 1440 (for 20 to 26 AWG wire) is an example of such a contactcrimper tool.Homemade Wire Harness ConsiderationsEach <strong>SkyView</strong> display includes its own wire harness (SV-HARNESS-D37) for connection to power,serial ports, USB, the external battery, and other connections. We recommend that you use thisharness for display installations instead of building your own.Here are some considerations if you build your own <strong>SkyView</strong> network wire harnesses.Wire InsulationWe recommend that all wire harness wires that are installed in aircraft utilize Tefzel® insulation.Twisted Pairs<strong>SkyView</strong> networks utilize two data wire pairs for communication between devices. This guiderefers to these pairs as Data 1 and Data 2 and each have an A and a B wire. These pairs shouldhave 8 to 10 twists per foot over their entire length.Heat Shrink Bundling and Strain ReliefAll wires should be bundled together with heat shrink and then strain relieved when exiting theconnector shell or hood.SV-BAT-320 ConnectionTo connect a homemade harness to an SV-BAT-320, the following specifications must befollowed closely for the SV-BAT-320 to charge and work correctly:Connector:Pins:Wire:Molex Micro-Fit P/N 43640-0301 (Digi-Key P/N WM1856-ND)Molex Micro-Fit P/N 43031-0007 (Digi-Key P/N WM1841-ND)22 AWG Tefzel, NO MORE THAN 24” LONG; red w/yellow: M22759/16-22-24;black: M22759/16-22-017-2 <strong>SkyView</strong> System Installation Guide - Revision J