13.07.2015 Views

SkyView - Dynon Avionics

SkyView - Dynon Avionics

SkyView - Dynon Avionics

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Appendix A: Maintenance and TroubleshootingTest Procedure1. Set the <strong>SkyView</strong> display to full brightness (PFD > press SCREEN > press DIM > press FULL)2. Fully charge the SV-BAT-320 Backup Battery. Reference the Battery Charging andBattery Status Check sections for battery charging instructions.3. Disconnect primary power from the <strong>SkyView</strong> display—ensure that the display is notpowered from another source4. Clear the POWERING DOWN IN # SECONDS message (press CLEAR)5. Allow the <strong>SkyView</strong> system to run off the backup batteryThe system passes if, after 60 minutes, it has not turned off.Repeat the test procedure for each backup battery in the system.This test discharges the backup battery. Recharging the battery after the test isrecommended. Do this by applying primary power to the display. The backupbattery is fully charged when its voltage reaches 12.25 volts.If a tested battery does not pass the annual backup battery test, please contact <strong>Dynon</strong> byphone or the online store (store.dynonavionics.com) to obtain a replacement battery.Please dispose of non‐functional <strong>SkyView</strong> backup batteries in a responsiblemanner. <strong>SkyView</strong> backup batteries are lithium-ion and similar in construction tocordless tool batteries. They can likely be recycled wherever cordless tool batteryrecycling is available. For a list of recycling locations in your area (USA only), call 1-800-8-BATTERY or see the Call 2 Recycle website at www.rbrc.org.TroubleshootingThe Display Hardware Information Page (SETUP MENU > LOCAL DISPLAY SETUP > DISPLAYHARDWARE INFORMATION) can be a valuable resource when troubleshooting <strong>SkyView</strong> and isdescribed in the previous section.If the suggestions below do not help, or your issue is not listed below, please call<strong>Dynon</strong> Technical Support at +1(425) 402-0433.Network Configuration Does Not Work or <strong>SkyView</strong> Network Module Is Not WorkingProperlyIf you try and configure a <strong>SkyView</strong> network and it does not work, try the following:Check network wiring and try again. There may be a short or an open somewhere.Unplug network modules one by one and try again. It is possible that one of themodules could cause the network to stop functioning.Try again.For modules such as the SV-ADAHRS-20X, the SV-EMS-220, and SV-ARINC-429, observethe red LED light near the <strong>SkyView</strong> Network connector:<strong>SkyView</strong> System Installation Guide - Revision J 15-7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!