Accessory Installation and ConfigurationGeneral Installation RecommendationsConnect the female BNC to the male BNC included with your capacitive fuel level sensor.Connect the wires as shown in the table to an enhanced general purpose input on the SV-EMS-220. If you need to extend the wire beyond the supplied length, we recommend avionics grade22 AWG wire with Tefzel® type insulation.Refer to the Fuel Level Sensor Section for EMS pin-out information when connecting thisproduct to your SV-EMS-220.You must configure the input type on the SV-EMS-220 to capacitive sender before calibratingthis product. Refer to the EMS Sensor Definitions, Mapping, and Settings Section forconfiguration instructions and the EMS Sensor Calibration Section for calibration procedures.Wire SV-EMS-220 Pin FunctionBlack Any ofGround5,13,16,17,20White Any one or twoof 8,22, or 31Capacitance converteroutput to EMS fuel levelinput (0 Vdc to 5 Vdc)Red 15 12 Vdc Power (normallyused for fuel flow)Table 45 – Capacitance-to-Voltage Converter Wiring<strong>SkyView</strong> System Installation Guide - Revision J 14-13