13.07.2015 Views

SkyView - Dynon Avionics

SkyView - Dynon Avionics

SkyView - Dynon Avionics

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Accessory Installation and ConfigurationFailure WarningDesigned to meet the indication requirements of FAR 23.1326, the heated pitot controller hasan output that can trigger a warning light in the cockpit whenever the probe heater is turnedoff or is not functioning properly. While not required for Experimental and LSA categoryaircraft, this feature provides peace of mind, giving you instant feedback that your probe’sheater is working as designed.Tools and Materials Required <strong>Dynon</strong> <strong>Avionics</strong> AOA/Pitot Probe Two plumbing lines (usually ¼” soft aluminum or plastic tubing) routed from the SV-ADAHRS-20X to the probe mounting location Tubing interface hardwareo Reference our wiki at wiki.dynonavionics.com for tubing interface hardwarerecommendations. #36 drill and #6-32 tap AOA Pitot Mounting bracket. Models known to work well can be found athttp://wiki.dynonavionics.com/AOA_Pitot_Brackets_and_Parts.Please follow these instructions explicitly as improper installation can result inpermanent damage to your device and/or aircraft.Heater Controller Module InstallationThis section addresses heater controller module installation. If you are installing the unheatedversion of the probe, you may skip to the AOA/Pitot Probe Mounting Section.14-2 <strong>SkyView</strong> System Installation Guide - Revision J