SV-BAT-320 InstallationPhysical InstallationThe diagram below shows the mounting dimensions of the backup battery.Figure 49–SV-BAT-320 Mounting Dimensions<strong>Dynon</strong> does not provide mounting hardware for use with the SV-BAT-320. The mounting tabson each side of the module have holes sized for #8 fasteners. Button head style AN hardware isrecommended as spacing between the holes in the tabs and the body of the enclosure limitswhat style tool can be used to tighten certain fasteners. Follow recommended torque practiceswhen tightening the mounting hardware.Use of ferrous fasteners in this location is acceptable. Do not rivet the SV-BAT-320 to theaircraft as this will hinder future removal if necessary.Electrical ConnectionConnect the SV-BAT-320 module’s connector to the mating connector on the main displayharness.Battery Charging<strong>SkyView</strong> displays automatically manage their connected battery’s charge level. If it becomesdischarged, simply turning the <strong>SkyView</strong> display on will cause the battery to charge.9-2 <strong>SkyView</strong> System Installation Guide - Revision J