SV-EMS-220 Installation and ConfigurationExample Voltmeter SetupAssume this sensor was mapped on the Sensor Input Mapping Wizard as:PIN # FUNCTION SENSOR NAMEC37 P1 VOLTS VOLTAGE MEASURE MAINNow, we want to configure its alert and graphical properties. Go to the Sensor Setup Menu andopen the MAIN VOLTS Page (SETUP MENU > EMS SETUP > SENSOR SETUP > MAIN VOLTS).Configure MAIN VOLTS with the following properties: ALARM: OFF MAXIMUM GRAPHICAL DISPLAY: 15.0 VOLTS MINIMUM GRAPHICAL DISPLAY: 10.0 VOLTS RANGE 1o ENABLEo COLORo TOPo BOTTOM RANGE 2o ENABLEo COLORo TOPo BOTTOM RANGE 3o ENABLEo COLORo TOPo BOTTOM RANGE 4o ENABLEo COLORo TOPo BOTTOM RANGE 5o ENABLEo COLORo TOPo BOTTOMYESRED11.0 VOLTS10.0 VOLTSYESYELLOW12.0 VOLTS11.0 VOLTSYESGREEN13.6 VOLTS12.0 VOLTSYESYELLOW14.6 VOLTS13.6 VOLTSYESRED15.0 VOLTS14.6 VOLTSFigure 38—Anatomy of a Widget:Main Volts7-48 <strong>SkyView</strong> System Installation Guide - Revision J