13.07.2015 Views

RTD7AL - Pentair

RTD7AL - Pentair

RTD7AL - Pentair

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>RTD7AL</strong>RTD Temperature Sensor for Temperature measurement up to 900°F (482°C) inDivision 1 locations Installation InstructionsDescriptionThe <strong>RTD7AL</strong> temperature sensor is a three-wire platinum RTD(resistance temperature detector) typically used with monitoringand control systems when accurate temperature control isrequired. The sensor is explosion proof and approved for Division1 and 2 hazardous locations. The <strong>RTD7AL</strong> can be used with a widevariety of DigiTrace monitoring and control systems.These installation instructions detail the installation of the<strong>RTD7AL</strong> in conjunction with existing DigiTrace component kits.Tools Required• 3.5 mm flat-blade screwdriverAdditional Materials Required• Pipe strap• Conduit with 16–22 AWG shielded instrument cable or equivalentarmored cable3/4 in NPTconduitopening4.25 in.(108 mm)ApprovalsThe <strong>RTD7AL</strong> is CSA Certified for use in North America by themanufacturer for use in Division 1 and Division 2 hazardous locationsas follows:Kit ContentsClass I, Division 1, Groups C, DClass II, Division 1, Groups E, F, GClass I, Division 2, Groups A, B, C, DClass II, Division 2, Groups E, F, G2 in. (51 mm)3 in. (76 mm)Qty Description1 RTD Temperature SensorSpecificationsSensor housing Zinc-plated cast-iron body with aluminumcap; NEMA 4, 7Sensor sheath 316 stainless steelRange–100 to 900°F (–73 to 482°C) maxAccuracy ±1°F (0.5°C) at 32°F (0°C)Resistance 100 ohms at 0°C α =0.00385 ohms/ohm/°CConnection 3/4 in. NPT conduit hubWARNING:This component is an electrical device. It must be installedcorrectly to ensure proper operation and to prevent shock orfire. Read these important warnings and carefully follow all theinstallation instructions. Component approvals and performanceare based on the use of specified parts only. Do not use substituteparts or vinyl electrical tape to make connections.THERMAL MANAGEMENT SOLUTIONS EN-DigiTrace<strong>RTD7AL</strong>-IM-H56916 01/131 / 2


Wiring InformationThe length of RTD extension wires is determined by the wiregauge used.To reduce the likelihood that electrical noise will affecttemperature measurement, keep RTD extension wires as short aspossible.Use shielded instrument cable such as DigiTrace MONI-RTD-WIRE(22AWG, PVC insulation, –30°F to 140°F, –20°C to 60°C) or Belden83553 (22 AWG, FEP insulation, –95°F to 395°F, –70°C to 200°C).Maximum RTD extension wire lengthAWG Feet (meters)16 4500 (1400)18 2800 (880)20 1800 (550)22 1100 (340)RTD Direct ConnectionConduitdrainPipe strapPlace strap under heating cableC1D1 Installation with Heating CableElectrical Wiring Notes:Most electrical codes (such as NEC 725–15) permit Class 1 circuitsto occupy the same cable, enclosure, or raceway without regardto whether the individual circuits are alternating current or directcurrent, providing all conductors are insulated for the maximumvoltage of any conductors in the cable, enclosure or raceway.Additional Materials Required• Approved junction box (supplied by others)• HAK-C-100• Pipe strapPipe strapAgency approvedDiv 1 junction box(supplied by others)HAK-C-100Place pipe strap under heating cableDiv 2Div 1<strong>RTD7AL</strong> WiringConnect the wires as shown.1 Note: Ground RTD extension wire shield at oneend only, preferably at DigiTrace electronics end.2 Note: RTD housing must be properly groundedusing the screw provided.Electrical schematic of RTDWhiteRedField WiringWhite (Common return)Red (Source)RedRed (Compensate)WWW.THERMAL.PENTAIR.COMNORTH AMERICAEurope, Middle East, AfricaAsia PacificLatin AmericaTel: +1.800.545.6258Fax: +1.800.527.5703Tel: +1.650.216.1526Fax: +1.650.474.7711thermal.info@pentair.comTel: +32.16.213.511Fax: +32.16.213.603thermal.info@pentair.comTel: +86.21.2412.1688Fax: +86.21.5426.2917cn.thermal.info@pentair.comTel: +55.11.2588.1400Fax: +55.11.2588.1410thermal.info@pentair.com<strong>Pentair</strong> and DigiTrace are owned by <strong>Pentair</strong> or its global affiliates. All other trademarks are the property of their respective owners. <strong>Pentair</strong> reserves theright to change specifications without prior notice.© 2001-2013 <strong>Pentair</strong>. PN 229056-000THERMAL MANAGEMENT SOLUTIONS EN-DigiTrace<strong>RTD7AL</strong>-IM-H56916 01/132 / 2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!