<strong>COMBINATION</strong> – <strong>BEACON</strong> <strong>SOUNDER</strong>EExde, WeatherproofCU1 RangeGOSTATEXIntroductionThis range of beacon/sounder units, intended for usein potentially explosive gas and dust atmospheres,has a power rating of up to 10 watts (sounder) and10 joules (beacon) and is suitable for use in the harshenvironmental conditions found offshore and onshorein the oil, gas and petrochemical industries.The flamepaths, flare and body are manufacturedfrom a UV stable glass reinforced polyester. Stainlesssteel screws and mounting stirrup are incorporated toensure a corrosion-free product. A tapered flamepathis used to overcome the problems of assembly ofparallel spigot flamepaths.H Zone 1, Zone 2 & non-Ex use.H EExde IIB T3.H ATEX approved, Ex II 2 G.H CENELEC approved.H GOST 'R' & 'K' Certified.H BASEEFA certified.H Brazilian (Inmetro) certified.H IP66 and 67.H Certified temperature –50°C to +70°C*.H Up to 116 dB(A)*.H Version with independent beacon/sounderoperation now available.H 27 Tones, user selectable (dual tone option)H Tones comply with UK00A/PFEER guidelinesH Integral volume controlH GRP corrosion-free flamepath.H Ratcheted swivel mouting stirrup.H Stainless steel fixtures.H Tapered flamepath.*Model dependent.TUCANO COMERCIO DE ALARMES E SISTEMAS ELETRONICOS - www.tucanobrasil.com.br


Integral Volume Control:Nominal Output (dB(A) Input Current (mA)90 46095 520100 670102 720105 1000107 1220116 1387*Output measured with 24V input voltage. Tone set to 970Hz continuous,with 10 joule beacon set to 60 fpm.Current Consumption at full power:Input Voltage 10 Joule Beacon Sounder @ 60 fpm 5 Joule Beacon Sounder @ 60 fpm24Vd.c. 1387mA 700mA†48Vd.c.864mA110Va.c.365mA120Va.c.417mA230Va.c.172mA240Va.c.182mA250Va.c.241mAIn addition to the 10 Joule CU1, MEDC offers a 5 Joule/110dB(A),24Vd.c. version. Details are available on request.SpecificationCertification: CENELEC EN50014, 18 & 19.Baseefa Cert. No. Baseefa04ATEX0273X EExde IIB T3Zones 1 & 2.Brazilian (Inmetro) Certified: BR-Ex de IIB T3GOST R Certification: 2 EXde IIB T3Russian Fire Alarm (VNIIPO) approved.GOST Certification: Exde IIB T3Material:Body, flares & covers: Glass Reinforced Polyester (GRP).Lens: GlassGuard fitted as standardCover screws & mounting strap: Stainless steel.Ordering RequirementsThe following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for eachcomponent into the appropriate box. For standard products, available ex-stock, contact sales office for details.Finish:Weight:CertifiedTemperature:Natural black or epoxy painted to customer‘s requirements.6.5kg approx.IP Rating: IP66 & 67.Earth Cont:Standard unit: -50°C to +50°C (CU1-S & CU1-SP).High temperature unit: -50°C to +70°C (CU1-H & CU1-HP).Available as an option.Terminals: 8 x 4.0mm 2 .Initiation:Labels:Entries:Mounting:MaximumOutput:SoundOutput:Remote relay or telephone initiate options available.Duty/tag label option to customer’s requirements.Up to 2 x M25, 2 x M25 ISO, 2 x M20 with ½" NPTadaptor or 2 x M25 with ¾" NPT adaptors into termination(EExe) chamber.Stainless steel bracket with ratchet facility.Standard unit: sounder 10 watts, beacon 5 or10 joules.High temp. unit: sounder 5 watts, beacon 5 or10 joules.Standard unit: 116dB(A) ± 3 dB(A) (tone dependent).High temp. unit: 110 dB(A) ±3 dB(A) (tone dependent).Tone Selection: 27 user selectable tones.Two Stage Unit: Switchable between any two tones by either:(i) reversing the polarity* of the supply, or(ii) by a 3 wire common +ve system, switching betweenthe two -ve lines.If a two stage unit is ordered with either IndependentSounder/Beacon operation or Telephone or Relay Initiate,it will be wired for reverse polarity tone switching only, toallow loop in, loop out installation.Note: Two stage unit available in d.c. versions only.*will not affect beacon operationUnit Type Certification Voltage Power FPM Lens Labels Options Entries FinishTypeStandard unitTwo stageHigh temp.Standard unitTwo stage*dc versions onlyCodeCU1SCU1SP*CU1HCU1HP*Certification CodeATEX BGOST 'R'* GGOST 'K' KInmetro EMWeatherproof W*VIINPO approvedas standardOption Code24Vd.c. 02448Vd.c. 048110V a.c. 110120V a.c. 120230V a.c. 230240V a.c. 240254V a.c. 254Power Code5 Joule F*10 Joule T*available24Vd.c onlyFPMCode60 0680 08120 12*Current consumptionavailable for 80 & 120fpm on request.LensRedBlueGreenAmberYellowClearCodeRBGAYCOption CodeNone NDuty Label DTag label TOption CodeTel. Initiate T †Relay Initiate R †IndependentBeacon/SounderOperation I †Earth cont. CSpecial Tone S*EOL Res. E*None N*Please specify†T, R or l not available onsame unitOption CodeNatural Black NRedRSpecial S**Please specifyEntries Code1 x M20 1B2 x M20 2B1 x M25 1C2 x M25 2C1 x ½" NPT 1M2 x ½" NPT 2M1 x ¾" NPT 1N2 x ¾" NPT 2NTo specify certified plug, suffix appropriatecode with ‘P’, e.g. 2BP is 2 xM20 entries with one certified plug.TUCANO COMERCIO DE ALARMES E SISTEMAS ELETRONICOS - www.tucanobrasil.com.br

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!