1. General IntroductionThe jet nebulizer functions by the Bernoulli principle by which compressed g<strong>as</strong> (air oroxygen) p<strong>as</strong>ses through a narrow orifice creating an area of low pressure at the outlet of theadjacent liquid feed tube. This results in <strong>drug</strong> solution being drawn up from the fluid reservoir<strong>and</strong> shattered into droplets in the g<strong>as</strong> stream. Jet nebulizers produce smaller droplets than dopMDIs, <strong>and</strong> these smaller droplets penetrate more e<strong>as</strong>ily to the small airways (74).Figure 1.4: Jet-Nenulizer DeviceThe choice of a proper nebulizer system is very crucial for the efficient <strong>delivery</strong> ofaerosolized respiratory <strong>drug</strong>s (75). Jet nebulizers are widely used, because of their durability,e<strong>as</strong>e of maintenance, <strong>and</strong> availability at low cost. In a jet nebulizer, compressed air is forcedthrough a narrow orifice, which leads to a decre<strong>as</strong>e in lateral pressure, thereby drawing upliquid from the feed tube. The primary droplets are produced in the nozzle region <strong>and</strong> thenbroken down into smaller droplets. The non-respirable droplets are removed by baffles (76).The droplets may incre<strong>as</strong>e in diameter because of condensation of water vapor. Thiscondensation occurs because the droplets are at a low temperature (about 10°C) after beingrele<strong>as</strong>ed from the nebulizer, if the surrounding air stream w<strong>as</strong> unsaturated (77).Fewer than 0.5% of the resultant droplets are small enough to leave the nebulizer; the largerdroplets drip back into the liquid to start the process again. Size distribution data for jetnebulizers come from a number of studies (78, 79, 80, 81, 82, 83). These kind of nebulizer areable to produce, from physiologically isotonic saline, initial droplets with aerodinamicdiameter from 1.6 to 4.9 µm.The size distribution of aerosol droplets from a jet nebulizer depends on the diameter of theliquid inlet orifice, the air velocity at the nozzle, <strong>and</strong> the ratio of the m<strong>as</strong>s flow rate of air to19

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!