13.07.2015 Views

Cable Carriers for 'C'-Tracks - VAHLE, Inc

Cable Carriers for 'C'-Tracks - VAHLE, Inc

Cable Carriers for 'C'-Tracks - VAHLE, Inc

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

TYPICAL APPLICATIONS AND HOW TO ORDER– cables & fittings see cat. 8 L –S 1 Track System (flat cable)Application: Electric hoist, outdoors with separate supply system <strong>for</strong> pendant controlCurrent load:11 kWVoltage:380 V, 50 HzRequired control cable: 7 x 1,5 mm 2Travel distance:28 mPerm. depth of loops:1 mTravel speed:35 m/minHow to select the correct cable festoon system:1. Take ampere load from cat. 8 L 22,5 A2. Select suitable cables (cat. 8 L) For main current: Neoprene flat<strong>for</strong>m cable4 x 2,5 mm 2 , dimensions: 8,2 x 24 mmFor control current: Neoprene flat<strong>for</strong>m cable8 x 1,5 mm 2 , dimensions: 6,4 x 32 mm3. Select cable carrier, see page 10 WS 1 F/85-PM4. <strong>Cable</strong> safety length, see page 49 f = 1,15. Determine number of cable loops, diagram page 50 176. Determine storage distance, <strong>for</strong>mula page 49SP = 17 x 85 mm + 85 mm = min. 1530 mm7. DDetermine length of cable, <strong>for</strong>mula page 49L = (28 m + 1,53 m) x 1,1 = 32,48 m + 2 x 1 m hookup ends = 35 m8. Control carrier, see page 18 ST-ST 1/A1Material to order: Typ Order-No.2 x 30 m Track (10 lengths of 6 m) S1 312 9462 x 17 Fixpoint hangers (1) FAS 1 310 5002 x 17 Pair of Bolts M 8 x 25 310 5102 x 4 Joint clamps VS 1 310 0502 x 2 End caps K 30 360 0232 x 16 <strong>Cable</strong> carriers WS 1 F/85-PM 312 6891 Lead carrier MS 1 F/85-PM 312 6922 x 1 Track clamp ES 1 F/85-PM 312 6933 Bumper stops PS 1-1 312 6051 Control carrier ST-ST 1/A1 312 695c/w:7 Terminal clamps SAK 2,5 330 8001 Terminal clamp <strong>for</strong> ground EK 2,5 NPA 331 2831 End plate APPA 2,5 331 2782 End angles EWK 1 331 288A-Seite: 1 flat cable gland <strong>for</strong> 8 x 1,5 mm 2 M 50 x 1,5-1 332 5521 counter nut M 50 x 1,5 332 535B-Seite: 1 round cable gland <strong>for</strong> 8 x 1,5 mm 2 M 25 x 1,5 332 5391 counter nut M 25 x 1,5 332 5331 Brake spring BF 1 310 8602 flat cable glands <strong>for</strong> 4 x 2,5 mm 2 M 32 x 1,5-1 332 5502 counter nut M 32 x 1,5 332 5341 flat cable gland <strong>for</strong> 8 x 1,5 mm 2 M 50 x 1,5-1 332 5521 counter nut M 50 x 1,5 332 53544(1)Consider permissible track area load (see diagram page 48).

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!