13.07.2015 Views

2-Kanal-Oszilloskope bis 500 MHz - Testo Industrial Services GmbH

2-Kanal-Oszilloskope bis 500 MHz - Testo Industrial Services GmbH

2-Kanal-Oszilloskope bis 500 MHz - Testo Industrial Services GmbH

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

14.00 - 15.00 h15.00 - 16.00 h16.00 h16.30 hPerspectives from Policy, Prevention and CareInputs by representatives of•••••Federal Office of Public Health: Roger Staub, MPHFederal Commission for AIDS-related Issues: Prof. Dr. PietroVernazzaSwiss AIDS Federation: Daniel BruttinLHIVE: Mic Rasmussen, dipl. Phys. ETHPLANeS: Anita CottingInterdisciplinary Perspectives and Funding IssuesInputs by representatives of•••Swiss HIV Cohort Study: Dr. Martin RickenbachSpecial Commission on HIV/AIDS Clinical Medicine andTreatment: Dr. Matthias CavassiniSwiss National Science Foundation:Interdisciplinary Research Commission: invited representativePatient-oriented Research Commission: PD Dr. Jens GaabAnd the Future?Debate regarding future networking and research initiativesClosing SessionInvitationto the 8 th Thun Networking Meeting on:Social Science and Public HealthResearch in the Field of HIV/AIDSin SwitzerlandPoster ExhibitionPosters will be on display throughout the whole of the meeting.Conference languagesOral presentations and discussion may take place in either French, German or English.Simultaneous translation will be available from French to German and vice versa.Further InformationMeeting place:Conference Secretariat:Registration:Hotel FreienhofFreienhofgasse 3CH-3600 ThunSonja RohrFachhochschule NordwestschweizHochschule für Soziale ArbeitInstitut Integration und PartizipationRiggenbachstrasse 16CH-4600 OltenPhone: +41 62 311 96 78Fax: +41 62 311 96 31E-mail: sonja.rohr@fhnw.chUntil 18th August 2008 at the Conference SecretariatDate:4 - 5 th September 2008Meeting place:Hotel Freienhof, ThunThis meeting is organized byUniversity Institute of Social and Preventive Medicine,University of LausanneUniversity of Applied Sciences Northwestern Switzerland,School of Social WorkIt is supported by theSwiss National Science FoundationVersion: 25.06.2008


Seite 2 zum Kalibrierschein vom 03.12.2012D-K-15070-01-01Umgebungsbedingungen ambient conditionsTemperatur temperatureFeuchte humidity23 °C ± 1°C Druck pressure 960 hPa ±30hPa40%rF %RH ±30 %rF %RHKalibrierverfahren calibration procedureDie Kalibrierung erfolgte durch Vergleich der Anzeige des Kalibriergegenstandes mit den durch die Kalibriergeräte/Normaledargestellten Messwerten.The calibration was conducted by direct comparison of the measured values of the calibration article with thereference-, or working-standard.Messunsicherheit measuring uncertaintyAngegeben ist die erweiterte Messunsicherheit, die sich aus der Standardmessunsicherheit durch Multiplikation mit demErweiterungsfaktor k = 2 ergibt. Sie wurde gemäß DAkkS-DKD-3 ermittelt. Der Wert der Messgröße liegt mit einerWahrscheinlichkeit von 95 % im zugeordneten Werteintervall. Ein Anteil für die Langzeit-Instabilität ist nicht enthalten.Die dimensionslosen Anteile der Messunsicherheit sind Relativwerte, bezogen auf den Anzeigewert.The expanded uncertainty of measurement corresponding to the measurement results is stated as the standard unvertainty ofmeasuremend multiplied by the coverage factor k = 2. This was determined in accordance with DAkkS-DKD-3. Usually thetrue value is located in the corresponding interval with a probability of ca. 95%.The non-dimensional fractions of the measuring uncertainty are relative values in relation to the indicated value.Prüfprozedur procedureF:Tektronix:TDS:Standard:TIS:5820A:IEEEEquipment Nr. equipment no.Inventar Nr. inventory no.Prüfmittel Nr. test equipment no.Bemerkungen notesDie mit ( * ) markierten Messwerte sind rückführbar auf Normale der Physikalisch-Technischen Bundesanstalt in Braunschweig,sind aber nicht akkreditiert.The measurements marked with (*) are traceable to standards at the German National Laboratory (PTB) in Braunschweig, butare not accredited measurements.Messeinrichtungen measuring equipmentReferenzreferenceRückführungtraceabilityRekal.next cal.Zertifikats Nr.certificate-no.Eq.-Nr.eq.-no.Oscilloscope Calibrator 5820A-5-GHz 15070-01-01 2013-03 E17848 10254777*Referenzzertifikate sind auf www.primasonline.de abrufbar Reference certificates are available at www.primasonline.de<strong>Testo</strong> <strong>Industrial</strong> <strong>Services</strong> <strong>GmbH</strong>Gewerbestraße 3 Tel +49 7661 90901-8000 www.testotis.de79199 Kirchzarten Fax +49 7661 90901-8010 info@testotis.de


Seite 3 zum Kalibrierschein vom 03.12.2012D-K-15070-01-01BereichrangeMesswertmeasured valueMessbedingungmeasuringmodeAngezeigterMesswertindicatedmeasured valueMessunsicherheituncertainty ofmeasuringSoftwarestand:v.3.41Eingangswiderstand RinpInput resistanceCH.11.000 MOhm0.9999 M Ohm580 · 10 -650.00 Ohm49.930 Ohm780 · 10 -6CH.21.000 MOhm0.9989 M Ohm970 · 10 -650.00 Ohm49.950 Ohm780 · 10 -6Eingangswiderstand @ 100mV/Div.Vertikalablenkung XdefVertical deflectionCH.18 mV6.000 mV1 mV/Div6.040 m V3,0 · 10 -316 mV12.000 mV2 mV/Div12.040 m V3,0 · 10 -340 mV30.00 mV5 mV/Div30.15 m V3,0 · 10 -380 mV60.00 mV10 mV/Div59.60 m V3,0 · 10 -3160 mV120.00 mV20 mV/Div120.15 m V3,0 · 10 -3400 mV300.0 mV50 mV/Div300.5 m V3,0 · 10 -3800 mV600.0 mV100 mV/Div596.0 m V3,0 · 10 -31.6 V1.2000 V200 mV/Div1.2011 V3,0 · 10 -34 V3.000 V<strong>500</strong> mV/Div3.005 V3,0 · 10 -38 V6.000 V1 V/Div5.960 V3,0 · 10 -316 V12.000 V2 V/Div12.011 V3,0 · 10 -340 V30.00 V5 V/Div30.00 V3,0 · 10 -380 V60.00 V10 V/Div59.60 V3,0 · 10 -3CH.28 mV6.000 mV1 mV/Div6.040 m V3,0 · 10 -316 mV12.000 mV2 mV/Div12.080 m V3,0 · 10 -340 mV30.00 mV5 mV/Div30.33 m V3,0 · 10 -380 mV60.00 mV10 mV/Div59.60 m V3,0 · 10 -3<strong>Testo</strong> <strong>Industrial</strong> <strong>Services</strong> <strong>GmbH</strong>Gewerbestraße 3 Tel +49 7661 90901-8000 www.testotis.de79199 Kirchzarten Fax +49 7661 90901-8010 info@testotis.de


Seite 4 zum Kalibrierschein vom 03.12.2012D-K-15070-01-01BereichrangeMesswertmeasured valueMessbedingungmeasuringmodeAngezeigterMesswertindicatedmeasured valueMessunsicherheituncertainty ofmeasuring160 mV120.00 mV20 mV/Div120.18 m V3,0 · 10 -3400 mV300.0 mV50 mV/Div301.4 m V3,0 · 10 -3800 mV600.0 mV100 mV/Div596.0 m V3,0 · 10 -31.6 V1.2000 V200 mV/Div1.2009 V3,0 · 10 -34 V3.000 V<strong>500</strong> mV/Div3.015 V3,0 · 10 -38 V6.000 V1 V/Div5.960 V3,0 · 10 -316 V12.000 V2 V/Div12.000 V3,0 · 10 -340 V30.00 V5 V/Div30.16 V3,0 · 10 -380 V60.00 V10 V/Div59.60 V3,0 · 10 -31 mV/Div -> 5 mV/Div: (BW Limit f = 20 <strong>MHz</strong>)10 mV/Div -> 10 V/Div: (BW Full f = <strong>500</strong> <strong>MHz</strong>)Erfassung:AmplitudeAVG.32Horizontalablenkung YdefHorizontal deflection10 ns10.0000 n s10.0018 n s5,8 · 10 -6100 ns100.000 n s100.001 n s5,8 · 10 -61 µs1.00000 µs1.00006 µ s5,8 · 10 -610 µs10.0000 µs9.9992 µ s5,8 · 10 -6100 µs100.000 µs100.018 µ s5,8 · 10 -61 ms1.00000 ms1.00002 m s5,8 · 10 -610 ms10.0000 ms9.9981 m s5,8 · 10 -6100 ms100.000 ms100.000 m s6,1 · 10 -6Erfassung:PeriodeAVG.32Vertikalablenkung XdefVertical deflectionDelta-Cursor600.0 mV@1kHz596.0 m V3,0 · 10 -3Horizontalablenkung YdefHorizontal deflectionDelta-Cursor<strong>Testo</strong> <strong>Industrial</strong> <strong>Services</strong> <strong>GmbH</strong>Gewerbestraße 3 Tel +49 7661 90901-8000 www.testotis.de79199 Kirchzarten Fax +49 7661 90901-8010 info@testotis.de


Seite 5 zum Kalibrierschein vom 03.12.2012D-K-15070-01-01BereichrangeMesswertmeasured valueMessbedingungmeasuringmodeAngezeigterMesswertindicatedmeasured valueMessunsicherheituncertainty ofmeasuring8.000 ms8.000 m s72 · 10 -6Anstiegszeit trise RisetimeCH.10.8 n s0.70 n s31 · 10 -3CH.20.8 n s0.72 n s31 · 10 -3Die Anstiegszeit wurde unter Verwendung derAnstiegszeit 10-90%, gemessen mit 250mVpp @ 1 <strong>MHz</strong>Testspannung Utest Test voltageProbe CompRechteckspannung (Uss/Vpp)Nominalwert: 5 VMesswert: 5.04 VDie Messunsicherheit beträgt U = 10 mVFrequenzNominalwert: 1.000 kHz Messwert: 1 kHzDie Messunsicherheit beträgt U = 10 Hz<strong>Testo</strong> <strong>Industrial</strong> <strong>Services</strong> <strong>GmbH</strong>Gewerbestraße 3 Tel +49 7661 90901-8000 www.testotis.de79199 Kirchzarten Fax +49 7661 90901-8010 info@testotis.de

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!