Catalog HY14-2502/USOrdering Information<s<strong>tr</strong>ong>Directional</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Con<strong>tr</strong>ol</s<strong>tr</strong>ong> ValvesSeries D3WConnectorPackageCodeCKJ#*PDescriptionConduit CavityConduit BoxDeutsch (DT06-2S)Hirschmann w/PlugW* Hirschmann w/o PlugE* Explosion Proof* Lights not available.# DC voltage only.Solenid/TubeOptionsCodeOmitManualOverrideOptionsDescriptionStandard TubeP* Extended ManualOverride* Not available with soft shiftor explosion proof.Elec<strong>tr</strong>icalOptionsShiftResponseandIndicationCodeOmitApprovalsDescriptionStandard Valve3*† CSA US (UL429)4* CSA Canada* Not available with AC highpressure tube option.† B, C, H styles only.Y voltage with conduitconnection only.VariationsDesignSeriesNOTE:Not requiredwhen ordering.AOptions Coil Tube RatingACDC/AC RectifiedOmit High Watt 103.5 Bar (1500 PSI) 207 Bar (3000 PSI)F*# Low Watt n/a 207 Bar (3000 PSI)H High Watt 207 Bar (3000 PSI) n/aD† Explosion Proof, EEXDU† Explosion Proof, UL/CSA* Available only with J, K, Y (Rectified) and T (Rectified) voltages.# Not available with soft shift or with F and M style valves.† Explosion proof coils are 60 Hz at standard voltage; dual rating notavailable.Valve Weight:Single Solenoid:ACDCDouble Solenoid:ACDCStandard Bolt Kit:Me<strong>tr</strong>ic Bolt Kit:Mounting Bolt Kits4.3 kg (9.5 lbs.)5.3 kg (11.6 lbs.)5.0 kg (11.0 lbs.)7.3 kg (16.0 lbs.)BK98BKM98UNC Bolt Kits for use with D3W<s<strong>tr</strong>ong>Directional</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Con<strong>tr</strong>ol</s<strong>tr</strong>ong> Valves & Manapak/CartpakCodeOmitNumber of Manapaks/Cartpaks@ 2.00" (50mm) thickness0 1 2 3D3W Standard: BK98 BK141 BK142 BK1431.62" 3.50" 5.50" 7.50"Me<strong>tr</strong>ic: BKM98 BKM141 BKM142 BKM14340mm 90mm 140mm 190mmD3W with Standard: BK144 BK61 BK62 BK63explosion 2.37" 4.25" 6.25" 8.25"proof coils Me<strong>tr</strong>ic: BKM144 BKM61 BKM62 BKM6360mm 110mm 160mm 210mmNOTE: All bolts are SAE grade 8, 1/4-20 UNC-2A thread, torque to16 Nm (12 ft-lbs)DescriptionNo OptionV# Varistor SurgeSuppressorZAC Rectifiedwith MOV SurgeSuppressor# DC voltage only.CodeOmitCodeOmitS3**S4**S7**DescriptionStandard ValveSoft Shift, 0.030" OrificeSoft Shift, 0.040" OrificeSoft Shift, 0.070" OrificeI7* Monitor Switch DirectOp. End S<strong>tr</strong>okeI8* Monitor Switch* Single solenoid models only. NotCE or CSA approved. Spools 8, 9,81 & 82 not available.** High watt coil only.DescriptionStandard Valve5 Signal Lights6 Manaplug, Brad Harrison Mini7 Manaplug, Brad Harrison Micro (M12x1)56 Manaplug (Mini) with Lights57 Manaplug (Micro) with Lights (M12x1)1A1B1C1DManaplug (Mini) Single Sol. 5-PinManaplug (Micro) Single Sol. 5-Pin (M12x1)Manaplug (Mini) Single Sol. 5-Pin w/LightsManaplug (Micro) Single Sol. 5-Pin w/Lights (M12x1)2502-A2.p65, ddBold: Designates Tier I products and options.Non-Bold: Designates Tier II products and options. These products will have longer lead times.A55<s<strong>tr</strong>ong>Parker</s<strong>tr</strong>ong> Hannifin CorporationHydraulic Valve DivisionElyria, Ohio, USA


Catalog HY14-2502/USTechnical Information<s<strong>tr</strong>ong>Directional</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Con<strong>tr</strong>ol</s<strong>tr</strong>ong> ValvesSeries D3WASolenoid Ratings**InsulationClass HAllowable Deviation DC, AC Rect -10% to +15%from rated voltage AC -5% to +5%ArmatureWet pin type** DC Solenoids available with optional molded metal oxide varistor(MOV) for surge suppression.Leadwire length 6” from coil face.D3W*****F Solenoid Elec<strong>tr</strong>ical Characteristics‡Solenoid Nominal In Rush HoldingCode Volts/Hz Amps Amps WattsKF 12 VDC — 1.50 18JF 24 VDC — 0.75 18‡ Based on nominal voltage @ 22°C (72°F)D3W Solenoid Elec<strong>tr</strong>ical Characteristics†Solenoid Nominal In Rush Holding NominalCode Volts/Hz VA VA Watts (Ref)YTE120/60 298 95110/50 294 102240/60 288 96220/50 288 10124/60 290 7724/50 381 110323232K 12 VDC — 3.00† 36J 24 VDC — 1.50† 36D 120 VDC — 0.30† 36U 98 VDC — 0.37† 36Z 250 VDC — 0.14† 36† DC holding amps.Explosion Proof SolenoidsD3W Rectified AC Solenoid Elec<strong>tr</strong>icalCharacteristics‡Solenoid Nominal In Rush HoldingCode Volts/Hz Amps Amps WattsYTYF120/60110/50240/60220/50120/60110/50— .37 36— .18 36— .18 18TF 240/60 — .09 18220/50‡ Based on nominal voltage @ 22°C (72°F)Explosion Proof Solenoid RatingsU.L. (EU)C.S.A.ATEXClass I, Div. 1 & 2, Groups C & DClass II, Div 1 & 2, Groups E, F & GAs defined by the N.E.CComplies with ATEX requirements for:Exd, Group IIB;EN50014: 1999+ Amds 1 & 2,EN50018: 200Elec<strong>tr</strong>ical Characteristics* ED and EU†Solenoid Nominal In Rush Holding NominalCode Volts/Hz VA VA Watts (Ref)Y 120/60 266 82 36T 240/60 266 82 36K 12 VDC — 3.00† 36J 24 VDC — 1.50† 36D 120 VDC — 0.30† 36* Dual frequency not available on explosion proofcoils.† DC holding amps.2502-A2.p65, ddA56<s<strong>tr</strong>ong>Parker</s<strong>tr</strong>ong> Hannifin CorporationHydraulic Valve DivisionElyria, Ohio, USA


Catalog HY14-2502/USDimensions<s<strong>tr</strong>ong>Directional</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Con<strong>tr</strong>ol</s<strong>tr</strong>ong> ValvesSeries D3WInch equivalents for millimeter dimensions are shown in (**)Hirschmann, Double AC SolenoidA36.0(1.42)90.0(3.54)86.2(3.40)107.7(4.24)89.8(3.54)69.5(2.74)58.0(2.29)12.0 (.47)23.0 (.91)74.5(2.93) 97.8(3.85)21.5(.85)76.2(3.00)27.3(1.08)129.1(5.09)152.5(6.01)Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve.Hirschmann, Single AC Solenoid36.0(1.42)86.2(3.40)90.0(3.54)107.7(4.24)89.8(3.54)69.5(2.74)SeeNote58.0(2.29)12.023.0 (.47)(.91)74.597.8(2.93)(3.85)21.5(.85)76.2(3.00)27.3(1.08)87.9(3.45)Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve.2502-A2.p65, ddA57<s<strong>tr</strong>ong>Parker</s<strong>tr</strong>ong> Hannifin CorporationHydraulic Valve DivisionElyria, Ohio, USA


Catalog HY14-2502/USDimensions<s<strong>tr</strong>ong>Directional</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Con<strong>tr</strong>ol</s<strong>tr</strong>ong> ValvesSeries D3WInch equivalents for millimeter dimensions are shown in (**)AConduit Cavity, Double DC Solenoid36.0(1.42)86.2(3.40)90.0(3.54)69.5(2.74)58.0(2.29)23.0(.91)12.0(.47)122.5(4.83)21.5(.85)76.2(3.00)27.3(1.08)177.2(6.98)Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve.Conduit Cavity, Single DC Solenoid36.0(1.42)86.2(3.40)90.0(3.54)69.5(2.74)58.0(2.29)23.0(.91)12.0(.47)122.5(4.83)21.5(.85)76.2(3.00)27.3(1.08)87.9(3.46)Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve.2502-A2.p65, ddA58<s<strong>tr</strong>ong>Parker</s<strong>tr</strong>ong> Hannifin CorporationHydraulic Valve DivisionElyria, Ohio, USA


Catalog HY14-2502/USDimensions<s<strong>tr</strong>ong>Directional</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Con<strong>tr</strong>ol</s<strong>tr</strong>ong> ValvesSeries D3WInch equivalents for millimeter dimensions are shown in (**)Conduit Box, Single AC Solenoidwith Variation 6 (Manaplug) & Variation P (Extended Manual Override)AExtended Manual Override15.9(.63)36.0(1.42)103.1(4.06)128.6(5.07)“A” SolenoidReverse Sides for#8 & #9 Spools.69.5(2.74)“B” SolenoidReverse Sides for#8 & #9 Spools.58.0(2.29)12.023.0 (.47)(.91)97.8(3.85)Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve.21.5(.85)112.2(4.42)27.3(1.08)74.1(2.92) 76.2(3.00)166.9(6.58)152.5(6.01)Conduit Box, Double DC Solenoidwith Variation 6 (Manaplug) & Variation P (Extended Manual Override)Extended Manual Override15.9(.63)36.0128.6(5.07)(1.42)103.1(4.06)69.5(2.74)2502-A2.p65, dd58.0(2.29)12.023.0 (.47)(.91)140.4(5.53)Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve.A5921.5(.85)27.376.2 (1.08)(3.00)195.0(7.68)<s<strong>tr</strong>ong>Parker</s<strong>tr</strong>ong> Hannifin CorporationHydraulic Valve DivisionElyria, Ohio, USA


Catalog HY14-2502/USDimensions<s<strong>tr</strong>ong>Directional</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Con<strong>tr</strong>ol</s<strong>tr</strong>ong> ValvesSeries D3WInch equivalents for millimeter dimensions are shown in (**)AExplosion Proof U.L. & CSA, Double SolenoidBoltholeCenterlineReference#18 AWG, 18 Inches Long, No Terminals,with UL Approval and Markings1/2 Inch NPT36.0(1.42)18.9(0.74)98.0(3.86)11.7(0.46)18.9 (0.74) Ref.23.0(0.91)58.0(2.29)BoltholeCenterline12.0 Reference(0.47)Note: Mounting bolts included with valve.143.7(5.66)23.0(0.91)63.6(2.51)11.3 (0.44)64.9 (2.56)76.9 (3.03)117.2 (4.62)197.3 (7.77)AdapterPlateIncludedwithValveExplosion Proof ATEX, Double SolenoidM20 x 1.5-6H Me<strong>tr</strong>ic ThreadBoltholeCenterlineReferenceGround Stud2502-A2.p65, dd36.0(1.42)103.6(4.08)134.7(5.31)18.9 (0.74) Ref.18.9(0.74)11.6(0.46)23.0Bolthole23.0(0.91) 12.1 Centerline(0.91)58.1 (0.47) Reference75.6 (2.98)(2.29) 154.1(6.07)Note: Mounting bolts included with valve.A6011.3(0.44)76.7 (3.02)64.9 (2.56)207.7(8.18)<s<strong>tr</strong>ong>Parker</s<strong>tr</strong>ong> Hannifin CorporationHydraulic Valve DivisionElyria, Ohio, USA


Catalog HY14-2502/USDimensions<s<strong>tr</strong>ong>Directional</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Con<strong>tr</strong>ol</s<strong>tr</strong>ong> ValvesSeries D3WInch equivalents for millimeter dimensions are shown in (**)Conduit Box, Single DC Solenoidwith Variation I7 (Monitor Switch)ABoltholeCenterlineReference75.0(2.95)107.7(4.24)89.9(3.54) 89.9(3.54)98.8(3.89)36.0(1.42)23.0(0.91)58.0(2.28)12.0(0.47)BoltholeCenterlineReference74.5(3.93)97.8(3.85)21.5(0.85)176.2(6.94)Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve.Monitor Switch(valve variation I7) Start of S<strong>tr</strong>okeThis feature provides for elec<strong>tr</strong>ical confirmation ofthe spool shift. This can be used in safety circuits, toassure proper sequencing, etc.Switch DataInductive switch requiring +18-42 volt input. Outputs“A” and “B” are opposite; one at “0” voltage, theother at input voltage. During switching, “A” and “B”outputs reverse. Provides 0.4A switching current.For repetitive switch power-up conditions, please consult factory.2502-A2.p65, ddA61<s<strong>tr</strong>ong>Parker</s<strong>tr</strong>ong> Hannifin CorporationHydraulic Valve DivisionElyria, Ohio, USA


Catalog HY14-2502/USAccessories<s<strong>tr</strong>ong>Directional</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Con<strong>tr</strong>ol</s<strong>tr</strong>ong> ValvesSeries D3WAConduit Box(connection option K)Interface – 152.4 cm (6.0 inch) lead wires, 18 awg.– Meets NEMA 4 and IP67Manaplug(valve variations 6, 56, 1A, 1C)Interface – Brad Harrison Plug– 3-Pin for Single Solenoid– 5-Pin for Double SolenoidGroundWire #1 (Green)“B” Solenoid (Positive)Wire #1 (Red/White)“B” Solenoid (Negative)Wire #5 (Red/Black)Solenoid (Negative)Wire #3 (Red/Black)Solenoid (Positive)Wire #2 (Red/White)3-Pin Manaplug (Mini) with LightsSingle Solenoid Valves – Installed Opposite Side of Solenoid“A” Solenoid (Negative)Wire #2 (Red)“A” Solenoid (Positive)Wire #4 (Red/Yellow)GroundWire #3 (Green)5-Pin Manaplug (Mini) with LightsSingle Solenoid Valves – Installed Opposite Side of SolenoidDouble Solenoid Valves – Installed Over “A” Solenoid(“A” and “B” Solenoids Reversed for #8 and #9 Spools)Pins are as seen on valve (male pin connectors).Hirschmann Plug with Lights (P5)Manaplug - Micro Connector(valve variations 7, 57, 1B, 1D)Face View of PlugConforms to DIN43650, ISO4400, Form A 3-PinPins are as seen on valve (male pin connectors).2502-A2.p65, ddA62<s<strong>tr</strong>ong>Parker</s<strong>tr</strong>ong> Hannifin CorporationHydraulic Valve DivisionElyria, Ohio, USA


Catalog HY14-2502/USInstallation Information<s<strong>tr</strong>ong>Directional</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Con<strong>tr</strong>ol</s<strong>tr</strong>ong> ValvesSeries D3Fluid Re<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mendationsPremium quality hydraulic oil with a viscosity rangebetween 32-54 cSt (150-250 SSU) at 38°C (100°F) isre<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mended. The absolute operation viscosity range isfrom 16-220 cSt (80-1000 SSU). Oil should havemaximum anti-wear properties and rust and oxidation<strong>tr</strong>eatments.Fluids and SealsValves using synthetic, fire-resistant fluids requirespecial seals. When phosphate ester or its blends areused, FLUOROCARBON seals are required. Waterglycol,water-in-oil emulsions, and pe<strong>tr</strong>oleum oil may beused with NITRILE seals.Temperature Re<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mendationRe<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mended oil temperature:-29°C to +71°C (-20°F to +160°F)Fil<strong>tr</strong>ationFor maximum valve and system <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>ponent life, thesystem should be protected at a contamination level notto exceed 125 particles greater than 10 microns permilliliter of fluid. (SAE Class 4 or better, ISO Code16/13).Tank Line SurgesIf several valves are piped with a <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mon tank line, flowsurges in the line may cause unexpected spool shift.Detent style valves are most susceptible to this.Separate tank lines should be used when line surges areexpected in an application.Re<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mended Mounting PositionValve TypeDetent (Solenoid)Spring OffsetSpring CenteredRe<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mended Mounting PositionHorizontalUnres<strong>tr</strong>ictedUnres<strong>tr</strong>ictedSiltingSilting can cause any sliding spool valve to stick and notspring return, if held shifted under pressure for longperiods of time. The valve should be cycled periodicallyto prevent sticking.Single Pass OperationValve flow ratings are for double pass operation(with equal flow in both paths). When using these<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>ponents in single pass applications, flow capabilitiesmay be reduced. Consult your local <s<strong>tr</strong>ong>Parker</s<strong>tr</strong>ong>representative for details.Flow Path DataD3*Operator B*Note: On valves with 008 or 009 spool, A and/or B operatorsreverse sides. Flow paths remain the same as viewed from top ofvalve.Double Solenoid. With solenoid “A” energized, flow pathis P→A and B→T. When solenoid “B” is energized, flowpath is P→B and A→T. The center condition on a springcenteredvalve exists when both coils are de-energized,or during a <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>plete shift, as the spool passes throughcenter.Detent and Spring Offset. The center condition existson detent and spring offset valves only during spoolcrossover. To shift and hold a detented spool, only amomentary energizing of the solenoid is necessary. Theminimum duration of the signal is aproximately 0.13seconds for both AC and DC voltages. This position willbe held provided the spool center line is in a horizontalplane, and no shock or vibration is present to displacethe spool.Single Solenoid. Spring offset valves can be ordered insix styles: B, E, F, H, K and M. Flow path data for thevarious styles are described in the order chart.Lever Operated (on B end)Pull lever away from valvePush lever toward valveNote: Reverse with a #8 or #9 spool.P→A; B→TP→B; A→TOperator AElec<strong>tr</strong>ical FailureShould elec<strong>tr</strong>ic power fail, spring offset and springcentered valves will shift to the spring held position.Detented valves will stay in the last position held beforepower failure. If main flow does not fail or stopsimultaneously, machine actuators may continue tofunction in an undesirable manner or sequence.Loss of Pilot Pressure (D3A)Should a loss of pilot pressure occur, spring offset andspring centered valves will shift to the spring heldposition. Detented valves will remain in the last positionheld. If main hydraulic flow does not simultaneously stop,machine actuators may continue to function in anundesirable manner or sequence.Torque SpecificationsTorque values re<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mended for the bolts which mountthe valve to the manifold or subplate are as follows:1/4-20 thread (M6x1) torque 16.0 Nm (12 ft-lbs).A2502-A2.p65, ddA75<s<strong>tr</strong>ong>Parker</s<strong>tr</strong>ong> Hannifin CorporationHydraulic Valve DivisionElyria, Ohio, USA