See the full range - Norville Group Ltd.
See the full range - Norville Group Ltd. See the full range - Norville Group Ltd.
Industrial solutionsVerifier T2High-tech solution integratingcentring device and lensmeterMore than 50 jobs per hourPN 1130-0013-01The Verifier Pro Turbo 2 is a high-tech product solutionintegrating both the centring device and lensmeter.In the operating sequence, it is no longer necessaryto mark spectacle lenses on the lensmeter, as the taskof measuring, centring and blocking spectacle lensesis performed in an automated operating sequence.Key parameters and technical specifications.Your benefit by progress> Operation is easy to learn> The procedure is automatically controlled> The spectacle lenses are verified accordingto user-set tolerance tables.Your benefit from profitability> Fewer operating steps> Shorter processing periods> Less rejects> Higher precision> High reliability.Smart Cutout> Smart cut out function adapts centring in case lensesare too small according to tolerances tables.Technical dataHeightWidthDepthWeightHeight of glass retainer655 mm219 mm385 mm20 kg182 mmProcess periodSingle-focus lensBifocal lensProgressive lensTotal period for one spectacle lensDurée totale pour un montage20 s20 s20 s10 s60 sTechnical limitsMeasurement rangeSphere-12 / +12 dptMeasurement Cylinder-6 / + 6 dptCylinder shaft 0 - 180°Prism0 - 6 cm / mBasis 0 - 360°Addition0 - 3,5 dptRaw lens dimensionsMax / min diameter85 mm / 40 mmMax / min marginal thickness20 mm / 0,5 mmAccuracy of detection0,2 mmBlock range from lens centreHorizontal-20 / + 20 mmVertical-15 / + 15 mmAccuracy of blocker+ / - 0,1 mmInterfacesWecoRS232Ethernet TCP/IP1 Insertion ofspectacle lensWECO CL interface,compatible with other interfacesSerial interface RS232, data protocolaccording to OMAStandardUSB two USB interfacesOMA (VCA) compatible protocol2 Insertion of block 3 Spectacle lens afterblocking processSee accessories pages 49_5026
Industrial solutionsVM 2500Freeform lens analyzerProcess controlThe VM 2500 for Freeform allows you to precisely inspectany lens and in particular freeform progressive lenses.The freeform function makes it possible to inspectthe lens and to compare it to the theoretical map providedby the lens designer.The VM 2500 for Freeform is a high precision lensanalyzer based on the PowerMap (Hartman Wavefront3D Technology).This unique technology:> Provides real-time mapping measurement.> Over 1,000 measured points.> High precision.> PowerMap TM of the entire lens.The VM 2500 for Freeform includes state-of-the-artProcess controls:> Compare the theoretical and the processed lens(based on the Freeform XYZ file)> Connectivity with Rx servers (leading products)> One-button operation> Quality criteria, which can be used for Go/NoGo decision.Three Easy Steps:1. Upload reference lens, by using the XYZ progressive surface2. Measure the Freeform lens3. Compare theoretical lens to actual lens.27
- Page 1: Functional, professional,industrial
- Page 4: indexEdge 310 - page 8Edge 350 C -
- Page 10: Professional solutionsE.3Intelligen
- Page 14 and 15: Functionnal professional solutionsS
- Page 16 and 17: Comparison tableFunctions displayFu
- Page 18 and 19: TracersTrace 2 HCHighest quality te
- Page 20 and 21: Centring devicesCAD 4The new standa
- Page 22 and 23: Centring devicesCad 5 technical dat
- Page 24 and 25: Industrial solutionsOptomove softwa
- Page 28 and 29: BevelsBevelsSome explanationsFlexib
- Page 30 and 31: Professional Workshop solutionsSmoo
- Page 32 and 33: WorkshopDM3 DrillPN 68 00 011The DM
- Page 34 and 35: WorkshopOpticus Rivex 50PN 68 00 00
- Page 36 and 37: AccessoriesEdger 310 - 330 C - 350
- Page 38 and 39: Accessoriese.3SPARE PARTSREF 11 90
- Page 40 and 41: AccessoriesEdge 680SPARE PARTSREF 1
- Page 42 and 43: AccessoriesRoughing-WheelsPart Numb
- Page 44 and 45: Accessories430 / 450 / 450 drill /
- Page 46 and 47: AccessoriesTrace 3SPARE PARTSREF SV
- Page 48 and 49: AccessoriesCAD 4SPARE PARTSREF 21 3
- Page 50 and 51: AccessoriesVerifier T2adjustment to
- Page 52: Professional solutionsLuneau Techno
Industrial solutionsVerifier T2High-tech solution integratingcentring device and lensmeterMore than 50 jobs per hourPN 1130-0013-01The Verifier Pro Turbo 2 is a high-tech product solutionintegrating both <strong>the</strong> centring device and lensmeter.In <strong>the</strong> operating sequence, it is no longer necessaryto mark spectacle lenses on <strong>the</strong> lensmeter, as <strong>the</strong> taskof measuring, centring and blocking spectacle lensesis performed in an automated operating sequence.Key parameters and technical specifications.Your benefit by progress> Operation is easy to learn> The procedure is automatically controlled> The spectacle lenses are verified accordingto user-set tolerance tables.Your benefit from profitability> Fewer operating steps> Shorter processing periods> Less rejects> Higher precision> High reliability.Smart Cutout> Smart cut out function adapts centring in case lensesare too small according to tolerances tables.Technical dataHeightWidthDepthWeightHeight of glass retainer655 mm219 mm385 mm20 kg182 mmProcess periodSingle-focus lensBifocal lensProgressive lensTotal period for one spectacle lensDurée totale pour un montage20 s20 s20 s10 s60 sTechnical limitsMeasurement <strong>range</strong>Sphere-12 / +12 dptMeasurement Cylinder-6 / + 6 dptCylinder shaft 0 - 180°Prism0 - 6 cm / mBasis 0 - 360°Addition0 - 3,5 dptRaw lens dimensionsMax / min diameter85 mm / 40 mmMax / min marginal thickness20 mm / 0,5 mmAccuracy of detection0,2 mmBlock <strong>range</strong> from lens centreHorizontal-20 / + 20 mmVertical-15 / + 15 mmAccuracy of blocker+ / - 0,1 mmInterfacesWecoRS232E<strong>the</strong>rnet TCP/IP1 Insertion ofspectacle lensWECO CL interface,compatible with o<strong>the</strong>r interfacesSerial interface RS232, data protocolaccording to OMAStandardUSB two USB interfacesOMA (VCA) compatible protocol2 Insertion of block 3 Spectacle lens afterblocking process<strong>See</strong> accessories pages 49_5026