Actionpac EMB – Bespoke Control and Monitoring System - Actionair

Actionpac EMB – Bespoke Control and Monitoring System - Actionair Actionpac EMB – Bespoke Control and Monitoring System - Actionair

actionair.co.uk
from actionair.co.uk More from this publisher
13.07.2015 Views

Actionpac EMBOther Actionpac Damper Control SystemsElectro Mechanical SystemsAddressable SystemsEMS StandardControl and monitoring system.Actionpac Electro Mechanical smoke andfire damper control system.Automatic damper operation utilising relaylogic and LED indication of damperstatus.Standard Modular Construction.LED indication of damper status.Mains isolator.Test/Normal/Override Keyswitch.Lamp test facility.2 Versions (Mode 5 and Mode 6),available in 3 sizes, from Stock.Note:Actionpac EMS (Standard) or Actionpac EMB(Bespoke) Systems are recommended for areas wherethere are less than 50 dampers.Actionpac 60/120The Actionair Actionpac 60/120 (LNSStandard) System consists of a Panel PC,UPS and pre-loaded software. Thesystem communicates with damperinterfaces to provide intelligent controland monitoring of motorised dampersand monitoring of manual fire dampers.The data network cabling enablessubstantial reduction in costs whencompared with conventional systems.The digital inputs and output device(DI804) is accommodated within thepanel enclosure.The Panel PC is supplied with ActionairActionpac 60/120 (LNS Standard)software and operates on an embeddedplatform, which is extremely user friendly.The server architecture delivers newbenefits such as reduced commissioningtime, ease of configuration, simplifiedoperation, full diagnostics for system anddevice integration along with optionalautomatic scheduled damper testing.Note: Actionpac 60/120 is recommend when there aremore than 50 smoke/fire dampers to be controlled andmonitored. Refer to Actionpac 60/120 (LNS Standard)brochure for full details.Actionpac LNS3The Actionpac LNS3 System consists ofa Panel PC, UPS and pre-loadedsoftware. The system communicates withdamper interfaces to provide intelligentcontrol and monitoring of motoriseddampers and monitoring of manual firedampers. The data network cabling enablessubstantial reduction in costs whencompared with conventional systems.Digital inputs and outputs (DI804) can beaccommodated on the network cable orlocated within the panel enclosure.The Panel PC is supplied with ActionpacLNS3 software and operates on anembedded platform, which is extremelyuser friendly. The server architecturedelivers new benefits such as reducedcommissioning time, ease ofconfiguration, simplified operation, futuresystem growth, full diagnostics for systemand device integration along with optionalautomatic scheduled damper testing.Ruskin Air Management LimitedSouth Street, Whitstable, KentCT5 3DU England.Tel: 01227 276100Fax: 01227 264262Email: sales@actionair.co.ukWebsite: www.actionair.co.ukRuskin Air Management Limitedis a ISO 9001 and 14001registered companyBROCHURE PRODUCTION www.geoffstrange.co.uk

<strong>Actionpac</strong> <strong>EMB</strong>Other <strong>Actionpac</strong> Damper <strong>Control</strong> <strong>System</strong>sElectro Mechanical <strong>System</strong>sAddressable <strong>System</strong>sEMS <strong>–</strong> St<strong>and</strong>ard<strong>Control</strong> <strong>and</strong> monitoring system.<strong>Actionpac</strong> Electro Mechanical smoke <strong>and</strong>fire damper control system.Automatic damper operation utilising relaylogic <strong>and</strong> LED indication of damperstatus.St<strong>and</strong>ard Modular Construction.LED indication of damper status.Mains isolator.Test/Normal/Override Keyswitch.Lamp test facility.2 Versions (Mode 5 <strong>and</strong> Mode 6),available in 3 sizes, from Stock.Note:<strong>Actionpac</strong> EMS (St<strong>and</strong>ard) or <strong>Actionpac</strong> <strong>EMB</strong>(<strong>Bespoke</strong>) <strong>System</strong>s are recommended for areas wherethere are less than 50 dampers.<strong>Actionpac</strong> 60/120The <strong>Actionair</strong> <strong>Actionpac</strong> 60/120 (LNSSt<strong>and</strong>ard) <strong>System</strong> consists of a Panel PC,UPS <strong>and</strong> pre-loaded software. Thesystem communicates with damperinterfaces to provide intelligent control<strong>and</strong> monitoring of motorised dampers<strong>and</strong> monitoring of manual fire dampers.The data network cabling enablessubstantial reduction in costs whencompared with conventional systems.The digital inputs <strong>and</strong> output device(DI804) is accommodated within thepanel enclosure.The Panel PC is supplied with <strong>Actionair</strong><strong>Actionpac</strong> 60/120 (LNS St<strong>and</strong>ard)software <strong>and</strong> operates on an embeddedplatform, which is extremely user friendly.The server architecture delivers newbenefits such as reduced commissioningtime, ease of configuration, simplifiedoperation, full diagnostics for system <strong>and</strong>device integration along with optionalautomatic scheduled damper testing.Note: <strong>Actionpac</strong> 60/120 is recommend when there aremore than 50 smoke/fire dampers to be controlled <strong>and</strong>monitored. Refer to <strong>Actionpac</strong> 60/120 (LNS St<strong>and</strong>ard)brochure for full details.<strong>Actionpac</strong> LNS3The <strong>Actionpac</strong> LNS3 <strong>System</strong> consists ofa Panel PC, UPS <strong>and</strong> pre-loadedsoftware. The system communicates withdamper interfaces to provide intelligentcontrol <strong>and</strong> monitoring of motoriseddampers <strong>and</strong> monitoring of manual firedampers. The data network cabling enablessubstantial reduction in costs whencompared with conventional systems.Digital inputs <strong>and</strong> outputs (DI804) can beaccommodated on the network cable orlocated within the panel enclosure.The Panel PC is supplied with <strong>Actionpac</strong>LNS3 software <strong>and</strong> operates on anembedded platform, which is extremelyuser friendly. The server architecturedelivers new benefits such as reducedcommissioning time, ease ofconfiguration, simplified operation, futuresystem growth, full diagnostics for system<strong>and</strong> device integration along with optionalautomatic scheduled damper testing.Ruskin Air Management LimitedSouth Street, Whitstable, KentCT5 3DU Engl<strong>and</strong>.Tel: 01227 276100Fax: 01227 264262Email: sales@actionair.co.ukWebsite: www.actionair.co.ukRuskin Air Management Limitedis a ISO 9001 <strong>and</strong> 14001registered companyBROCHURE PRODUCTION www.geoffstrange.co.uk

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!