13.07.2015 Views

צמנט רגיל צמנט : מסמך זה הוא הצעה בלבד מכון התקנים הישראלי

צמנט רגיל צמנט : מסמך זה הוא הצעה בלבד מכון התקנים הישראלי

צמנט רגיל צמנט : מסמך זה הוא הצעה בלבד מכון התקנים הישראלי

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ועדה 10601EN 197-1:2011 (E)Table 6 — Properties, test methods and minimum testing frequencies for the autocontrol testing by themanufacturer, and the statistical assessment procedureAutocontrol testingMinimum testingfrequencyStatistical assessmentprocedurePropertyCementsto be testedTestmethod a bRoutinesituationInitial periodfor a newtype ofcementInspection byVariables cAttributes1 2 3 4 5 6 7Early strengthStandard strengthAll EN 196-1 2/week 4/week xInitial setting time All EN 196-3 2/week 4/week x dSoundness(Expansion)All EN 196-3 1/week 4/week xLoss on ignition CEM I, CEM III EN 196-2 2/month e 1/week x dInsoluble residue CEM I, CEM III EN 196-2 2/month e 1/week x dSulfate content All EN 196-2 2/week 4/week x dChloride content All EN 196-2 2/month e 1/week x dC 3Ain clinker fCEM I-SR 0CEM I-SR 3CEM I-SR 5CEM IV/A-SRCEM IV/B-SREN 196-2 g 2/month 1/week x d- hPozzolanicity CEM IV EN 196-5 2/month 1/week xHeat of hydrationLow heatcommoncementsEN 196-8orEN 196-91/month 1/week x dComposition All - i 1/month 1/weeka Where allowed in the relevant part of EN 196, other methods than those indicated may be used provided they giveresults correlated and equivalent to those obtained with the reference method.b The methods used to take and prepare samples shall be in accordance with EN 196-7.cdIf the data are not normally distributed then the method of assessment may be decided on a case-by-case basis.If the number of samples is at least one per week during the control period, the assessment may be made by variables.e When none of the test results within a period of 12 months exceeds 50 % of the characteristic value the frequency maybe reduced to one per month.f The test method for the determination of C 3A content of clinker from an analysis of the final cement is underdevelopment in CEN/TC51.g In the specific case of CEM I, it is permissible to calculate the C 3A content of clinker from the chemical analysis of thecement. The C 3A content shall be calculated by the formula: C 3A = 2,65 A – 1,69 F (see 5.2.1).h Until the test method is finalised the C 3A content of clinker (see 5.2.1) shall be determined on the basis of the analysisof clinker as part of the manufacturer's Factory Production Control (EN 197-2:2000, 4.2.1.2).iAppropriate test method chosen by the manufacturer.23

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!