AISC Test Specimen 730-over<br />
“Required Strength” = slip critical strength of 24 bolts in splice plate<br />
Comparison of ASD Codes (using design values)<br />
slip<br />
shear<br />
bearing<br />
MUST-SIM<br />
Specimen 02<br />
730-over<br />
Pn<br />
(kips)<br />
AISC 2005 ASD 1989<br />
rank<br />
Pn/Ω<br />
(kips)<br />
rank<br />
Pallow<br />
(kips)<br />
University of Illinois at Urbana-Champaign<br />
December 5, 2007<br />
rank<br />
between splice<br />
and top column<br />
922 1 524 1 692 1<br />
between splice<br />
and bot. column<br />
2,459 3 1,397 4 1,845 4<br />
between splice<br />
and top column<br />
1,789 2 895 2 954 2<br />
between splice<br />
and bot. column<br />
between splice<br />
4,771 5 2,386 5 2,545 5<br />
and top column<br />
(overstrength)<br />
between splice<br />
2,460 4 1,230 3 1,312 3<br />
and bot. column<br />
(overstrength)<br />
6,561 6 3,280 6 3,499<br />
splice plate 7,449 3,725 3,221 6<br />
w shape 18,287 9,144 7,907