<strong>Gasifier</strong> <strong>Experimenters</strong> <strong>Kit</strong>Here's what we found . . .Air In: Atmosphere to Nozzles:The air preheating lines are raising theincoming air to 450-500C by the point wherethe air lines penetrate the bottom of thereactor and head upwards to the nozzles. Thisis adjacent to the base of the reduction bell,where the syngas exiting temp is 600-650C.This is around a 150C temp differential,which is likely about as good as we can hopefor in a winding gas-to-gas heat exchanger.The air temp raises another 100C or sobetween the reactor bottom and the insides ofthe nozzles. We measured 550-625C insidehttp://www.allpowerlabs.org/gasification/gek/gekreports/report3/report3.html (6 of 10) [10/9/2008 08:04:38]