TILT-UP CONSTRUCTION - Brock White

TILT-UP CONSTRUCTION - Brock White TILT-UP CONSTRUCTION - Brock White

brockwhite.com
from brockwhite.com More from this publisher
13.07.2015 Views

Coil InsertsB-14 Coil Bolts and Minimum Coil Penetration Information• B-14 coil bolts have fast-acting, self-cleaning threadsand are available in 3/4”, 1”, 1-1/4” and 1-1/2” diameterbolts.• Bolts are furnished with integrally formed heads.Hex HeadHardwareHeightCoilInsert SetbackMinimum CoilPenetration• May be reused—but will wear and must be regularlyinspected.Lifting SystemsCoil Inserts• Must be kept clean and lubricated.• When determining overall length of lifting bolt seeexample on page 62 —you must consider:A. Height of hardwareB. Insert SetbackC. Minimum coil penetration• Minimum coil penetration shown in the charts belowapplies to all coil products.Minimum Thread LengthBolt LengthSufficient Void Beyond CoilCreated by Setting Bolt,Setting Stud, or InsertLocator Plug to preventLift Bolt From “Bottoming”Out.To Order:Specify:(1) Quantity, (2) Type, (3) Diameter ofBolt, (4) Length of Bolt, (5) TypeExample:300 pcs., B-14 Coil Bolts, 1” diameter, 5” longwith welded on B-25 Coil Nut HeadB-14 Coil Bolts High Strength with Integrally Formed Hex Heads(Fabricated from Blanks Meeting ASTM A-325 Standards)3/4” Diameter 1” Diameter 1-1/4” Diameter 1-1/2” DiameterForged Hex Nut Forged Hex Nut Forged Hex Nut Forged Hex NutSafe Working Load Safe Working Load Safe Working Load Safe Working LoadTension Shear Tension Shear Tension Shear Tension Shear8,000 lbs. 5,300 lbs. 14,500 lbs. 9,600 lbs. 20,300 lbs. 13,500 lbs. 29,500 lbs. 19,600 lbs.Minimum Coil Penetration2-1/4”BoltLengthMinimumThreadLengthMinimum Coil Penetration2-1/2”BoltLengthMinimumThreadLengthMinimum Coil Penetration2-1/2”BoltLengthMinimumThreadLengthMinimum Coil Penetration3”BoltLengthMinimumThreadLength3” 2-3/4” 3” 2-3/4” 3” 2-3/4” — —4” 3-3/4” 4” 3-3/4” 4” 3-3/4” 4” 3-3/4”5” 4-3/4” 5” 4-3/4” 5” 4-3/4” 5” 4-3/4”6” 5-3/4” 6” 5-3/4” 6” 5-3/4” 6” 5-3/4”Over 6” 5-3/4” Over 6” 5-3/4” Over 6” 5-3/4” Over 6” 5-3/4”Approximate safety factor 5 to 1, for tilt-up hardware.64 04-09

Coil InsertsT-8 Lifting Angle• Designed for use with T-2 Double Pick-Up Inserts.• Shorter bolts are required than those used with swivellifting plates, normally 4” lengths.• May be used for face lifting inserts and also edge liftinginserts when panel thickness exceeds 6”.• Cut washers are required under head of all bolts.• Made from structural steel angle 6” x 6” x 3/4” x 21” longwith 1/2” diameter hole for clevis attachment.• Safe working load is 18,000 Ibs.T-8 T-1212”For 1-1/4” Bolts5”T-26 Double Swivel Lifting Plate• Designed for use with 1”, 1-1/4” and 1-1/2” diameter coilbolts.• Rotates 360 degrees in horizontal plane and 180 degreesin vertical plane.• Round bearing plate provides maximum safety whenused with any coil bolt lifting system.• Heavy forged bail is made of hi-strength material.• Double swivel action allows bail to rotate in direction ofapplied load.• Safe working load is 9,000 Ibs. for 1” diameter.• Safe working load is 13,500 for 1-1/4” and 1-1/2” diameter.Type Bolt Size H DT-26 1” Diameter 2-11/16”” 5”T-26 1-1/4” or 1-1/2” Diameter 2-3/4” 7”Lifting SystemsCoil Inserts15”For 1-1/2” Bolts21”6” x 6” x 3/4” AngleT-12 Swivel Lift Plate• Designed for use with single pick-up inserts.• Can be used for face lifting or edge lifting• Available for use with 3/4” or 1” diameter bolts.• Complete unit made of forged steel.• Safe working loads: 3/4” diameter is 7,200 Ibs. and1” diameter is 9,000 lbs.Type Bolt Size Bearing Plate2-1/2”5”T-12 3/4” Diameter 1/2 x 2-1/2 x 5”T-12 1” Diameter 1/2 x 2-1/2 x 5”SWL provides a factor of safety of approximately 5 to 1.Safety Notes• All plates must have full bearing on flat, smoothsurfaces• Lifting angle and plates must not be used with outa bolt fastener of sufficient strength to develop therequired loads.• Lifting angle and plates are to be used only withthe bolt diameter for which they were designed.For example use a 3/4” bolt with a 3/4” SwivelLifting Plate, do not use a 3/4” bolt with a 1”,1-1/4” or 1-1/2” T-12 Swivel Lifting Plate• All plates must be securely fastened to the slabs.• For exposed aggregate panels, a groute pad isrequired too provide for the bearing plate• Coil bolt penetration must agree with minimums.1-3/8”SWL provides a factor of safety of approximately 5 to 1.T-26 T-27HD5-1/2” 1” Thick12”18”T-27 Edge Lifting Plate• Designed for use with T-3 or T-11 pick-up inserts.• Made from structural steel plate 1” x 4” x 18” long.• Cut washers are required under head of all bolts.• For use with 3/4” or 1” diameter inserts.• For panels 6” or more in thickness, use T-8.• Safe working load is 8,800 Ibs.Warning! Never use T-27 with face inserts.To Order:T-12 or T-26: (1) Quantity, (2) Type, (3) SizeExample:24 pcs., T-26 Double Swivel Lifting Plate for 1-1/4”bolts.To Order:T-8 or T-27: (1) Quantity, (2) Type, (3) SizeExample:8 pcs., T-8 Lifting Angles.4”Danger! Crane line loads & bails of swivel and double swivel lifting plates must be turned in direction of crane forces beforelifting operations begin. Crane line loads must not be allowed to apply sideward loads to bails of Swivel Lifting Plates orClevis Attachment Plates of Lifting Angle or Lifting Plate, as this condition is dangerous and could lead to failure of hardware.04-0965

Coil InsertsB-14 Coil Bolts and Minimum Coil Penetration Information• B-14 coil bolts have fast-acting, self-cleaning threadsand are available in 3/4”, 1”, 1-1/4” and 1-1/2” diameterbolts.• Bolts are furnished with integrally formed heads.Hex HeadHardwareHeightCoilInsert SetbackMinimum CoilPenetration• May be reused—but will wear and must be regularlyinspected.Lifting SystemsCoil Inserts• Must be kept clean and lubricated.• When determining overall length of lifting bolt seeexample on page 62 —you must consider:A. Height of hardwareB. Insert SetbackC. Minimum coil penetration• Minimum coil penetration shown in the charts belowapplies to all coil products.Minimum Thread LengthBolt LengthSufficient Void Beyond CoilCreated by Setting Bolt,Setting Stud, or InsertLocator Plug to preventLift Bolt From “Bottoming”Out.To Order:Specify:(1) Quantity, (2) Type, (3) Diameter ofBolt, (4) Length of Bolt, (5) TypeExample:300 pcs., B-14 Coil Bolts, 1” diameter, 5” longwith welded on B-25 Coil Nut HeadB-14 Coil Bolts High Strength with Integrally Formed Hex Heads(Fabricated from Blanks Meeting ASTM A-325 Standards)3/4” Diameter 1” Diameter 1-1/4” Diameter 1-1/2” DiameterForged Hex Nut Forged Hex Nut Forged Hex Nut Forged Hex NutSafe Working Load Safe Working Load Safe Working Load Safe Working LoadTension Shear Tension Shear Tension Shear Tension Shear8,000 lbs. 5,300 lbs. 14,500 lbs. 9,600 lbs. 20,300 lbs. 13,500 lbs. 29,500 lbs. 19,600 lbs.Minimum Coil Penetration2-1/4”BoltLengthMinimumThreadLengthMinimum Coil Penetration2-1/2”BoltLengthMinimumThreadLengthMinimum Coil Penetration2-1/2”BoltLengthMinimumThreadLengthMinimum Coil Penetration3”BoltLengthMinimumThreadLength3” 2-3/4” 3” 2-3/4” 3” 2-3/4” — —4” 3-3/4” 4” 3-3/4” 4” 3-3/4” 4” 3-3/4”5” 4-3/4” 5” 4-3/4” 5” 4-3/4” 5” 4-3/4”6” 5-3/4” 6” 5-3/4” 6” 5-3/4” 6” 5-3/4”Over 6” 5-3/4” Over 6” 5-3/4” Over 6” 5-3/4” Over 6” 5-3/4”Approximate safety factor 5 to 1, for tilt-up hardware.64 04-09

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!