TILT-UP CONSTRUCTION - Brock White
TILT-UP CONSTRUCTION - Brock White TILT-UP CONSTRUCTION - Brock White
Coil InsertsB-14 Coil Bolts and Minimum Coil Penetration Information• B-14 coil bolts have fast-acting, self-cleaning threadsand are available in 3/4”, 1”, 1-1/4” and 1-1/2” diameterbolts.• Bolts are furnished with integrally formed heads.Hex HeadHardwareHeightCoilInsert SetbackMinimum CoilPenetration• May be reused—but will wear and must be regularlyinspected.Lifting SystemsCoil Inserts• Must be kept clean and lubricated.• When determining overall length of lifting bolt seeexample on page 62 —you must consider:A. Height of hardwareB. Insert SetbackC. Minimum coil penetration• Minimum coil penetration shown in the charts belowapplies to all coil products.Minimum Thread LengthBolt LengthSufficient Void Beyond CoilCreated by Setting Bolt,Setting Stud, or InsertLocator Plug to preventLift Bolt From “Bottoming”Out.To Order:Specify:(1) Quantity, (2) Type, (3) Diameter ofBolt, (4) Length of Bolt, (5) TypeExample:300 pcs., B-14 Coil Bolts, 1” diameter, 5” longwith welded on B-25 Coil Nut HeadB-14 Coil Bolts High Strength with Integrally Formed Hex Heads(Fabricated from Blanks Meeting ASTM A-325 Standards)3/4” Diameter 1” Diameter 1-1/4” Diameter 1-1/2” DiameterForged Hex Nut Forged Hex Nut Forged Hex Nut Forged Hex NutSafe Working Load Safe Working Load Safe Working Load Safe Working LoadTension Shear Tension Shear Tension Shear Tension Shear8,000 lbs. 5,300 lbs. 14,500 lbs. 9,600 lbs. 20,300 lbs. 13,500 lbs. 29,500 lbs. 19,600 lbs.Minimum Coil Penetration2-1/4”BoltLengthMinimumThreadLengthMinimum Coil Penetration2-1/2”BoltLengthMinimumThreadLengthMinimum Coil Penetration2-1/2”BoltLengthMinimumThreadLengthMinimum Coil Penetration3”BoltLengthMinimumThreadLength3” 2-3/4” 3” 2-3/4” 3” 2-3/4” — —4” 3-3/4” 4” 3-3/4” 4” 3-3/4” 4” 3-3/4”5” 4-3/4” 5” 4-3/4” 5” 4-3/4” 5” 4-3/4”6” 5-3/4” 6” 5-3/4” 6” 5-3/4” 6” 5-3/4”Over 6” 5-3/4” Over 6” 5-3/4” Over 6” 5-3/4” Over 6” 5-3/4”Approximate safety factor 5 to 1, for tilt-up hardware.64 04-09
Coil InsertsT-8 Lifting Angle• Designed for use with T-2 Double Pick-Up Inserts.• Shorter bolts are required than those used with swivellifting plates, normally 4” lengths.• May be used for face lifting inserts and also edge liftinginserts when panel thickness exceeds 6”.• Cut washers are required under head of all bolts.• Made from structural steel angle 6” x 6” x 3/4” x 21” longwith 1/2” diameter hole for clevis attachment.• Safe working load is 18,000 Ibs.T-8 T-1212”For 1-1/4” Bolts5”T-26 Double Swivel Lifting Plate• Designed for use with 1”, 1-1/4” and 1-1/2” diameter coilbolts.• Rotates 360 degrees in horizontal plane and 180 degreesin vertical plane.• Round bearing plate provides maximum safety whenused with any coil bolt lifting system.• Heavy forged bail is made of hi-strength material.• Double swivel action allows bail to rotate in direction ofapplied load.• Safe working load is 9,000 Ibs. for 1” diameter.• Safe working load is 13,500 for 1-1/4” and 1-1/2” diameter.Type Bolt Size H DT-26 1” Diameter 2-11/16”” 5”T-26 1-1/4” or 1-1/2” Diameter 2-3/4” 7”Lifting SystemsCoil Inserts15”For 1-1/2” Bolts21”6” x 6” x 3/4” AngleT-12 Swivel Lift Plate• Designed for use with single pick-up inserts.• Can be used for face lifting or edge lifting• Available for use with 3/4” or 1” diameter bolts.• Complete unit made of forged steel.• Safe working loads: 3/4” diameter is 7,200 Ibs. and1” diameter is 9,000 lbs.Type Bolt Size Bearing Plate2-1/2”5”T-12 3/4” Diameter 1/2 x 2-1/2 x 5”T-12 1” Diameter 1/2 x 2-1/2 x 5”SWL provides a factor of safety of approximately 5 to 1.Safety Notes• All plates must have full bearing on flat, smoothsurfaces• Lifting angle and plates must not be used with outa bolt fastener of sufficient strength to develop therequired loads.• Lifting angle and plates are to be used only withthe bolt diameter for which they were designed.For example use a 3/4” bolt with a 3/4” SwivelLifting Plate, do not use a 3/4” bolt with a 1”,1-1/4” or 1-1/2” T-12 Swivel Lifting Plate• All plates must be securely fastened to the slabs.• For exposed aggregate panels, a groute pad isrequired too provide for the bearing plate• Coil bolt penetration must agree with minimums.1-3/8”SWL provides a factor of safety of approximately 5 to 1.T-26 T-27HD5-1/2” 1” Thick12”18”T-27 Edge Lifting Plate• Designed for use with T-3 or T-11 pick-up inserts.• Made from structural steel plate 1” x 4” x 18” long.• Cut washers are required under head of all bolts.• For use with 3/4” or 1” diameter inserts.• For panels 6” or more in thickness, use T-8.• Safe working load is 8,800 Ibs.Warning! Never use T-27 with face inserts.To Order:T-12 or T-26: (1) Quantity, (2) Type, (3) SizeExample:24 pcs., T-26 Double Swivel Lifting Plate for 1-1/4”bolts.To Order:T-8 or T-27: (1) Quantity, (2) Type, (3) SizeExample:8 pcs., T-8 Lifting Angles.4”Danger! Crane line loads & bails of swivel and double swivel lifting plates must be turned in direction of crane forces beforelifting operations begin. Crane line loads must not be allowed to apply sideward loads to bails of Swivel Lifting Plates orClevis Attachment Plates of Lifting Angle or Lifting Plate, as this condition is dangerous and could lead to failure of hardware.04-0965
- Page 15 and 16: General andTechnical InformationBon
- Page 17 and 18: Panel ErectionInformationPanel Anal
- Page 19 and 20: Panel ErectionInformationStress Tab
- Page 21 and 22: Panel ErectionInformationStrongback
- Page 23 and 24: Panel ErectionInformationonto the s
- Page 25 and 26: Panel ErectionInformationStandard R
- Page 27 and 28: Panel ErectionInformationBrace and
- Page 29 and 30: Dayton SuperiorLifting SystemsDayto
- Page 31 and 32: SuperiorLifting SystemMinimum Inser
- Page 33 and 34: SuperiorLifting SystemT-110 Superio
- Page 35 and 36: Ground Release IISystemT-41 Ground
- Page 37 and 38: Ground Release IISystemHow to use t
- Page 39 and 40: Ground Release IISystemT-42 Double
- Page 41 and 42: Ground Release IISystemHow to use t
- Page 43 and 44: Ground Release IISystemP-52 Swift L
- Page 45 and 46: Ground Release IISystemHow To Insta
- Page 47 and 48: Ground Release IISystemP-60 Swift L
- Page 49 and 50: Gyro Tilt PlusSystemGyro Tilt Plus
- Page 51 and 52: Gyro Tilt PlusSystemT-50 Gyro Tilt
- Page 53 and 54: Gyro Tilt PlusSystemHow to Remove t
- Page 55 and 56: Tilt-Up 3Lifting SystemTILT-UP 3 LI
- Page 57 and 58: Tilt-Up 3Lifting SystemHow to Remov
- Page 59 and 60: Tilt-Up 3Lifting SystemMinimum Inse
- Page 61 and 62: Coil InsertsT-2 Double Pick-up Inse
- Page 63 and 64: Coil InsertsHow to use Coil Face In
- Page 65: Coil InsertsTotal System and Safe W
- Page 69 and 70: Strongback SystemStrongbacksWhen op
- Page 71 and 72: Strongback SystemT-13-D Strongback
- Page 73 and 74: Strongback SystemT-63 Aluminum Stro
- Page 75 and 76: Bracing InformationBrace LoadingBra
- Page 77 and 78: Bracing InformationBrace to Floor S
- Page 79 and 80: Bracing InformationKnee, Lateral an
- Page 81 and 82: Bracing InformationBracing to Cylin
- Page 83 and 84: Bracing InformationT-13 COIL-ANCHOR
- Page 85 and 86: Bracing InformationT-4 Brace Anchor
- Page 87 and 88: Bracing InformationBrace Length and
- Page 89 and 90: Sandwich PanelConnectorsP-24 Delta
- Page 91 and 92: Sandwich PanelConnectorsDelta Tie I
- Page 93 and 94: Form LinersWhen it is time to choos
- Page 95 and 96: Form LinersWood Patterns4" Wide Age
- Page 97 and 98: Form LinersBlock PatternsBrick Patt
- Page 99 and 100: Form LinersStone PatternsRugged Fla
- Page 101 and 102: Form LinersVinyltite1.500" 1.500"0.
- Page 103 and 104: Form LinersApplication GuideTilt-Up
- Page 105 and 106: MiscellaneousT-58 Double Chamfer St
- Page 107 and 108: MiscellaneousRustications, Chamfers
- Page 109 and 110: MiscellaneousP-80 Shim StripsDayton
- Page 111 and 112: MiscellaneousMetal Supports for Reb
- Page 113 and 114: Cure Miscellaneous andBondbreakerBo
- Page 115 and 116: MiscellaneousCure andBondbreakerSur
Coil InsertsB-14 Coil Bolts and Minimum Coil Penetration Information• B-14 coil bolts have fast-acting, self-cleaning threadsand are available in 3/4”, 1”, 1-1/4” and 1-1/2” diameterbolts.• Bolts are furnished with integrally formed heads.Hex HeadHardwareHeightCoilInsert SetbackMinimum CoilPenetration• May be reused—but will wear and must be regularlyinspected.Lifting SystemsCoil Inserts• Must be kept clean and lubricated.• When determining overall length of lifting bolt seeexample on page 62 —you must consider:A. Height of hardwareB. Insert SetbackC. Minimum coil penetration• Minimum coil penetration shown in the charts belowapplies to all coil products.Minimum Thread LengthBolt LengthSufficient Void Beyond CoilCreated by Setting Bolt,Setting Stud, or InsertLocator Plug to preventLift Bolt From “Bottoming”Out.To Order:Specify:(1) Quantity, (2) Type, (3) Diameter ofBolt, (4) Length of Bolt, (5) TypeExample:300 pcs., B-14 Coil Bolts, 1” diameter, 5” longwith welded on B-25 Coil Nut HeadB-14 Coil Bolts High Strength with Integrally Formed Hex Heads(Fabricated from Blanks Meeting ASTM A-325 Standards)3/4” Diameter 1” Diameter 1-1/4” Diameter 1-1/2” DiameterForged Hex Nut Forged Hex Nut Forged Hex Nut Forged Hex NutSafe Working Load Safe Working Load Safe Working Load Safe Working LoadTension Shear Tension Shear Tension Shear Tension Shear8,000 lbs. 5,300 lbs. 14,500 lbs. 9,600 lbs. 20,300 lbs. 13,500 lbs. 29,500 lbs. 19,600 lbs.Minimum Coil Penetration2-1/4”BoltLengthMinimumThreadLengthMinimum Coil Penetration2-1/2”BoltLengthMinimumThreadLengthMinimum Coil Penetration2-1/2”BoltLengthMinimumThreadLengthMinimum Coil Penetration3”BoltLengthMinimumThreadLength3” 2-3/4” 3” 2-3/4” 3” 2-3/4” — —4” 3-3/4” 4” 3-3/4” 4” 3-3/4” 4” 3-3/4”5” 4-3/4” 5” 4-3/4” 5” 4-3/4” 5” 4-3/4”6” 5-3/4” 6” 5-3/4” 6” 5-3/4” 6” 5-3/4”Over 6” 5-3/4” Over 6” 5-3/4” Over 6” 5-3/4” Over 6” 5-3/4”Approximate safety factor 5 to 1, for tilt-up hardware.64 04-09