13.07.2015 Views

Electricity meters for modular enclosures and DIN rail

Electricity meters for modular enclosures and DIN rail

Electricity meters for modular enclosures and DIN rail

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

DELTAmaxSpecial features - RTC, PV, LP, MD, log <strong>and</strong> THDDELTAmax has an internal clock that h<strong>and</strong>les a number oftime dependent functions such as load profile, maximumdem<strong>and</strong>, previous values, event <strong>and</strong> quality log, time controlledoutputs <strong>and</strong> tariffs. The data from these functionsare only readable via serial communication. When all availablememory <strong>for</strong> a time dependent function is used, theoldest data record <strong>for</strong> that function will be over-written.Changing interval length or number of values to stored ina function will reset all values stored.Internal clockThe internal clock, sometimes called real time clock or RTC, hasa built-in calendar <strong>and</strong> keeps automatically track of leap year <strong>and</strong>daylight savings time (DST). The DST function is optional.Backup of the clock during a power failure is provided by a supercapacitor.The time is controlled from a quartz crystal based clock..Time <strong>and</strong> date is set via push buttons or via communication.The internal clock is approved according to IEC 62052-21 <strong>and</strong>IEC 62054-21. These st<strong>and</strong>ards specify the requirements <strong>for</strong> timeswitches in electricity meter related products. The accuracy isbetter than 5 ppm at room temperature.Previous valuesThe previous value feature will store all energy registers <strong>and</strong> inputcounter values together with a date/time stamp upon change ofday or month. All total values are stored <strong>and</strong> in <strong>meters</strong> equippedwith the tariff feature all the tariff registers will also be stored.Load ProfileThe load profile stores the energy consumption at pre-definedintervals. The interval lengths are 15, 30 or 60 minutes. The defaultvalue is 60 minutes.The quantities that can be stored <strong>for</strong> each interval are active <strong>and</strong>reactive energy, both imported <strong>and</strong> exported energy, <strong>and</strong> thenumber of pulses registered on input 1 <strong>and</strong> 2. Storage of reactiveenergy is only possible on <strong>meters</strong> measuring combined energy<strong>and</strong> storing of pulses requires that the meter is equipped with thecorresponding number of inputs.The load profile function uses the st<strong>and</strong>ard time setting irrespectiveif the daylight savings time function is activated or not.Maximum Dem<strong>and</strong>In the maximum dem<strong>and</strong> function, the mean power in each intervalis measured <strong>and</strong> the maximum mean values are stored togetherwith a date/time stamp. The interval lengths are 15, 30 or 60 minutes.The default value is 15 minutes.For each set of maximum dem<strong>and</strong> values the end date/time ofthe period is stored.The quantities that can be stored <strong>for</strong> each interval are active <strong>and</strong>reactive energy (imported energy only), <strong>and</strong> the number of pulsesregistered on input 1 <strong>and</strong> 2. Storage of reactive energy is onlypossible on <strong>meters</strong> measuring combined energy <strong>and</strong> storing ofpulses requires that the meter is equipped with the correspondingnumber of inputs. In tariff <strong>meters</strong>, the maximum dem<strong>and</strong> is stored<strong>for</strong> each tariff.Event logThe event log function logs the following events:• Overvoltage on each phase (+6%)• Undervoltage level 1 on each phase (-10%)• Undervoltage level 2 on each phase (-15%)• Phase voltage outage (-15%)• Negative power• Total power outage• Presence of current harmonicsFor the over- <strong>and</strong> undervoltage events a percentage level withrespect to a nominal voltage is given which is programmable. Thephase voltage outage level use the same level as undervoltagelevel 2. The negative power event will be logged if abnormalnegative power is detected.For current harmonics a percentage level <strong>for</strong> the total harmonicdistorsion of the harmonics measured can be set <strong>and</strong> the eventwill be logged if that limit is exceeded.THDThe current harmonics (2-9) together with the fundamental ismeasured sequentially one at a time (approximately 1 harmoniceach second). The total current harmonic distortion of the harmonicsmeasured is displayed in percent. The separate harmonicfrequencies measured are multiples of the fundamental frequency(normally around 50 or 60 Hz) up to the 9th harmonic but nothigher than 500 Hz. At 60 Hz <strong>for</strong> example the 9th harmonic willhave frequency 540 Hz <strong>and</strong> will then not be measured.THD data is displayed on the LCD. THD data <strong>and</strong> data <strong>for</strong> individualharmonics can be read out via serial communication.36 <strong>Electricity</strong> <strong>meters</strong> | 2CMC480022C0003

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!