13.07.2015 Views

Electricity meters for modular enclosures and DIN rail

Electricity meters for modular enclosures and DIN rail

Electricity meters for modular enclosures and DIN rail

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

O<strong>DIN</strong>singleTechnical dataSingle phase meter, direct connection up to 65A Types OD 1065 <strong>and</strong> OD 1365Voltage (V) Nominal voltage AC 1 x 220 - 240Voltage range-20% to +15% of nominal voltageCurrent (A) I min 0.25I tr 0.5I ref (I b ) 5I n -I max 65I st20 mAGeneral data Frequency (Hz) 50/60Frequency range ± 5%Accuracy Class B (Cl. 1)Power consumption current circuits at 230 VAC <strong>and</strong> I ref0.004 VA, 0.004 WPower consumption voltage curcuits1.0 VA, 1.0 WSt<strong>and</strong>ards MID approval according to EN 50470-1, EN 50470-3International approlval according to IEC 62052-11, IEC 62053-21Memory back-upClock back-upClock accuracyEEpromTemperature range (°C) Operating -25 to +55N/AN/AStorage -25 to +70Trans<strong>for</strong>mer ratio Voltage trans<strong>for</strong>mer ratio N/ACurrent trans<strong>for</strong>mer ratioN/AMax trans<strong>for</strong>mer ratioN/AEnclosure material Upper PolycarbonateLowerGlassfibre rein<strong>for</strong>ced polycarbonateEnvironment Mechanical environment M1Electromagnetical environmentE2Resistance to heat <strong>and</strong> fire According to IEC 60695-2-10, IEC 60695-2-11:Terminal 960°C, Cover 650°CHumidity75% yearly average, 95% on 30 days/yearConnection area main terminals Current terminals 1 x mm 2 1 - 16Voltage terminals 1 x mm 2N/AProtection against penetration of dust <strong>and</strong> water According to IEC 60529 IP 20 on terminal block without protective enclosure *)Pulse output (only OD 1365) Connection area, main terminals, - 1 x mm 2 0 - 2.5External pulse voltage- Voltage (V) DC 5 - 40 (Transistor output)- Voltage (V) AC/DC N/AMax. current (mA) 100Pulse length (ms) 100 (± 2.5)Pulse frequency (imp/kWh) 100St<strong>and</strong>ardIEC 62053-31 (SO)LED Pulse frequency (imp/kWh) 1000Pulse length (ms) 40DisplayBacklit LCD with 6 digits, height 6 mmElectromagnetic compability (EMC) Impuls voltage test (kV) 6, 1.2 / 50µs (IEC 60060-1, HD 588.1 S1)Fast transient burst test (kV) 4 (IEC 61000-4-4)Radio frequency immunity 80 MHz - 2 GHz at 10 V/m (IEC 61000-4-3)Electrostatic discharge (ESD) (kV) 15 (IEC 61000-4-2)Tariff inputs (optional) Max. voltage (V) AC N/AMax. wire size (mm 2 )N/AInput voltage range (V) ACN/ATerminal wire area (mm 2 ) M-Bus N/ALonWorks FTT-10AN/ADimensions Width (mm) 35.8Height (mm) 85Depth (mm) 63.4<strong>DIN</strong> modules 2*) To comply with the protection requirements the meter must be mountedin a class IP 51 enclosure or better, acc to IEC 60529.2CMC480022C0003| <strong>Electricity</strong> <strong>meters</strong> 15

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!