Quickstart 750-881 - Wago
Quickstart 750-881 - Wago Quickstart 750-881 - Wago
34 Application example: Starterkit881_App1_FUP.pro WAGO-I/O-SYSTEM 750750-881 ETHERNET Programmable Fieldbus4.3 Main Program "PLC_PRG"Select the object PLC_PRG in the Modules tab in order to open the mainprogram.You will see the variable declaration in the upper part of the dialog box. Theindividual FUB networks are displayed in the lower part. You can activate thedigital outputs (Network 1 and Network 2) and call up the subprograms"UserLED" and "Blink" (Network 3 and Network 4) in the main program.Figure 30: "PLC_PRG" programQuickstart ReferenceVersion 1.1.0
WAGO-I/O-SYSTEM 750 Application example: Starterkit881_App1_FUP.pro 35750-881 ETHERNET Programmable FieldbusYou can activate the first digital output using a bistable function block "rsDO1"applying RS logic (reset = dominant).The "SET" input of the "rsDO1" function block is linked to a flank-detectingfunction block "ftrigDO1", which detects the falling flank for "xVisuDO1".The "RESET1" input is linked via a logical AND gate that evaluates the signal forflank detection "ftrigDO1.Q" and the status of the first digital output "xDO1."Figure 31: Network 1 (PLC-PRG)This linking of flank detection, AND gate, and bistable flip-flop yields thefollowing function:• If the digital output "xDO1" has not been set, then clicking thecorresponding visualization button [xVisuDO1] will set the digital output"xDO1."• If the digital output "xDO1" has already been set, then clicking thevisualization button [xVisuDO1] will result in the digital output "xDO1"being reset.4.4 Subprogram "Blink"The "Blink" subprogram is located in the Utilities folder.Figure 32: "Blink" programQuickstart ReferenceVersion 1.1.0
- Page 1 and 2: Pos : 3 /Alle Serien (Allgemeine M
- Page 3 and 4: === Ende der Liste für T extmar ke
- Page 5 and 6: Pos : 9.4.1 /Alle Serien (Allgemein
- Page 7 and 8: Pos : 10 /D okumentation allgemei n
- Page 9 and 10: Pos: 12.7 /Dokumentation allgemein/
- Page 11 and 12: Pos : 12.11.5 /Alle Serien (Allgeme
- Page 13 and 14: Pos : 17 /Serie 750 ( WAGO-I/O-SYST
- Page 15 and 16: WAGO-I/O-SYSTEM 750 Quickstart Desc
- Page 17 and 18: WAGO-I/O-SYSTEM 750 Quickstart Desc
- Page 19 and 20: WAGO-I/O-SYSTEM 750 Quickstart Desc
- Page 21 and 22: WAGO-I/O-SYSTEM 750 Quickstart Desc
- Page 23 and 24: WAGO-I/O-SYSTEM 750 Quickstart Desc
- Page 25 and 26: WAGO-I/O-SYSTEM 750 Quickstart Desc
- Page 27 and 28: WAGO-I/O-SYSTEM 750 Quickstart Desc
- Page 29 and 30: WAGO-I/O-SYSTEM 750 Application exa
- Page 31 and 32: WAGO-I/O-SYSTEM 750 Application exa
- Page 33: WAGO-I/O-SYSTEM 750 Application exa
- Page 37 and 38: WAGO-I/O-SYSTEM 750 Application exa
- Page 39 and 40: WAGO-I/O-SYSTEM 750 Application exa
- Page 41 and 42: WAGO-I/O-SYSTEM 750 Application exa
- Page 43 and 44: WAGO-I/O-SYSTEM 750 Application exa
- Page 45 and 46: WAGO-I/O-SYSTEM 750 Application exa
- Page 47 and 48: WAGO-I/O-SYSTEM 750 Application exa
- Page 49 and 50: WAGO-I/O-SYSTEM 750 List of Figures
- Page 51 and 52: === Ende der Liste für T extmar ke
WAGO-I/O-SYSTEM <strong>750</strong> Application example: Starterkit<strong>881</strong>_App1_FUP.pro 35<strong>750</strong>-<strong>881</strong> ETHERNET Programmable FieldbusYou can activate the first digital output using a bistable function block "rsDO1"applying RS logic (reset = dominant).The "SET" input of the "rsDO1" function block is linked to a flank-detectingfunction block "ftrigDO1", which detects the falling flank for "xVisuDO1".The "RESET1" input is linked via a logical AND gate that evaluates the signal forflank detection "ftrigDO1.Q" and the status of the first digital output "xDO1."Figure 31: Network 1 (PLC-PRG)This linking of flank detection, AND gate, and bistable flip-flop yields thefollowing function:• If the digital output "xDO1" has not been set, then clicking thecorresponding visualization button [xVisuDO1] will set the digital output"xDO1."• If the digital output "xDO1" has already been set, then clicking thevisualization button [xVisuDO1] will result in the digital output "xDO1"being reset.4.4 Subprogram "Blink"The "Blink" subprogram is located in the Utilities folder.Figure 32: "Blink" program<strong>Quickstart</strong> ReferenceVersion 1.1.0