24 Quickstart Description WAGO-I/O-SYSTEM 750750-881 ETHERNET Programmable Fieldbus3.2.3.2 Assigning an IP address to the fieldbus controllerThe IP address must be unique in the network!To ensure error-free network communication, the IP addresses assigned to the PCand to the fieldbus controller must be unique within the network!In the event of an error, the following error message "IP address configurationerror" (error code 6 - error argument 6) is indicated by the I/O LED at the fieldbuscontroller restart.An IP address for the fieldbus controller can be assigned using the followingsetting possibilities:• Address selection switch (DIP switch),• WebBasedManagement (WBM),• DHCP,• BootP or• WAGO ETHERNET settings.The option for using the address selection switch is detailed in this QuickStartGuide. The other options are not described here, as these are explained completelyin the manual for the "750-881 ETHERNET Programmable Fieldbus Controller".Use the address selection switch to set the host ID (the last byte of the IP address),which is binary encoded in the range between 1 and 254.The network address consists of the first three bytes of the IP address; the factorydefault setting for this is 192.168.1. You can change this network address in theWebBasedManagement system under menu item TCP/IP in the dialog input field"Switch IP address."Table 6: IP Address StructureNetwork AddressHost ID192 . 168 . 1 . 100The IP address statically set previously by WebBasedManagement will beoverwritten with the address assigned by the address selection switch.Quickstart ReferenceVersion 1.1.0
WAGO-I/O-SYSTEM 750 Quickstart Description 25750-881 ETHERNET Programmable FieldbusValues 0 and 255 are predefined!Set the values 0 or 255 using the address selection switch. This activates the IPmodes provided. When a value of 0 is set, the IP configurations executed byWebBasedManagement will apply. Setting a value of 255 will activate addressallocation by DHCP.1. To assign a value (except for 0/255) for the host ID using the addressselection switch, you must first convert the host ID value to a binarynumeral.In the configuration example shown here, the host ID 100 is used for thefieldbus controller. The decimal value of "100" converts to a binary code of"01100100."Table 7: Binary Coding of Decimal Number 100MSBLSB0 1 1 0 0 1 0 02. Set the bits in order using the 8 DIP switches. Begin with DIP switch 1 toset Bit 0 (LSB) and continue up to DIP switch 8 for Bit 7 (MSB).Figure 16: Address selection switch with set IP address (192.168.1.100)3. Implement a restart of the fieldbus controller if you have adjusted theaddress selection switch, so that the changed IP configuration will beadopted.To do this, open the cover for the service interface and press the modeswitch down (e.g., using an actuation tool, Item No.: 210-720).Figure 17: Restarting the fieldbus controller via hardware resetQuickstart ReferenceVersion 1.1.0
- Page 1 and 2: Pos : 3 /Alle Serien (Allgemeine M
- Page 3 and 4: === Ende der Liste für T extmar ke
- Page 5 and 6: Pos : 9.4.1 /Alle Serien (Allgemein
- Page 7 and 8: Pos : 10 /D okumentation allgemei n
- Page 9 and 10: Pos: 12.7 /Dokumentation allgemein/
- Page 11 and 12: Pos : 12.11.5 /Alle Serien (Allgeme
- Page 13 and 14: Pos : 17 /Serie 750 ( WAGO-I/O-SYST
- Page 15 and 16: WAGO-I/O-SYSTEM 750 Quickstart Desc
- Page 17 and 18: WAGO-I/O-SYSTEM 750 Quickstart Desc
- Page 19 and 20: WAGO-I/O-SYSTEM 750 Quickstart Desc
- Page 21 and 22: WAGO-I/O-SYSTEM 750 Quickstart Desc
- Page 23: WAGO-I/O-SYSTEM 750 Quickstart Desc
- Page 27 and 28: WAGO-I/O-SYSTEM 750 Quickstart Desc
- Page 29 and 30: WAGO-I/O-SYSTEM 750 Application exa
- Page 31 and 32: WAGO-I/O-SYSTEM 750 Application exa
- Page 33 and 34: WAGO-I/O-SYSTEM 750 Application exa
- Page 35 and 36: WAGO-I/O-SYSTEM 750 Application exa
- Page 37 and 38: WAGO-I/O-SYSTEM 750 Application exa
- Page 39 and 40: WAGO-I/O-SYSTEM 750 Application exa
- Page 41 and 42: WAGO-I/O-SYSTEM 750 Application exa
- Page 43 and 44: WAGO-I/O-SYSTEM 750 Application exa
- Page 45 and 46: WAGO-I/O-SYSTEM 750 Application exa
- Page 47 and 48: WAGO-I/O-SYSTEM 750 Application exa
- Page 49 and 50: WAGO-I/O-SYSTEM 750 List of Figures
- Page 51 and 52: === Ende der Liste für T extmar ke
24 <strong>Quickstart</strong> Description WAGO-I/O-SYSTEM <strong>750</strong><strong>750</strong>-<strong>881</strong> ETHERNET Programmable Fieldbus3.2.3.2 Assigning an IP address to the fieldbus controllerThe IP address must be unique in the network!To ensure error-free network communication, the IP addresses assigned to the PCand to the fieldbus controller must be unique within the network!In the event of an error, the following error message "IP address configurationerror" (error code 6 - error argument 6) is indicated by the I/O LED at the fieldbuscontroller restart.An IP address for the fieldbus controller can be assigned using the followingsetting possibilities:• Address selection switch (DIP switch),• WebBasedManagement (WBM),• DHCP,• BootP or• WAGO ETHERNET settings.The option for using the address selection switch is detailed in this QuickStartGuide. The other options are not described here, as these are explained completelyin the manual for the "<strong>750</strong>-<strong>881</strong> ETHERNET Programmable Fieldbus Controller".Use the address selection switch to set the host ID (the last byte of the IP address),which is binary encoded in the range between 1 and 254.The network address consists of the first three bytes of the IP address; the factorydefault setting for this is 192.168.1. You can change this network address in theWebBasedManagement system under menu item TCP/IP in the dialog input field"Switch IP address."Table 6: IP Address StructureNetwork AddressHost ID192 . 168 . 1 . 100The IP address statically set previously by WebBasedManagement will beoverwritten with the address assigned by the address selection switch.<strong>Quickstart</strong> ReferenceVersion 1.1.0