13.07.2015 Views

OLV-3100K Oxypal Neo Pulse Oximeter - Nihon Kohden

OLV-3100K Oxypal Neo Pulse Oximeter - Nihon Kohden

OLV-3100K Oxypal Neo Pulse Oximeter - Nihon Kohden

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Pulse</strong> <strong>Oximeter</strong><strong>OLV</strong>-3100J/KHigh Quality SpO 2 MeasurementwithFrom newborn to adultFor the ward, ICU, OR and transport


Stable and accurate SpO 2 monitoring—PQI algorithm for stable SpO 2monitoringThe PQI (<strong>Pulse</strong> Quality Index) algorithm greatlyimproves SpO 2 measurement against body movement,small amplitude pulse waveform and external noisesuch as ESU, electric blanket and fluorescent lights.Large numerical data displayThe SpO 2 and pulse ratedisplays are large enough tobe read from a distance. Thedisplays are a different size andcolor for easy identification.Trendgraph and memoryOne or two selected trendgraph parameters, SpO 2 ,pulse rate, pulse amplitude, Ext_SpO 2 , and delta SpO 2 ,can be shown on the backlit LCD. Trending helps youevaluate the prognosis of the patient and determinetreatment. The trend time can be selected from 12,48 min and 2, 6, 12, and 24 hours. Up to 24 hours ofmemory is available.Dual SpO 2 measurementDual SpO 2 can be measured by using two <strong>Oxypal</strong> <strong>Neo</strong>pulse oximeters. This allows delta SpO 2 (differencebetween two SpO 2 values). Delta SpO 2 value andtrendgraph can be displayed. Dual SpO 2 measurementallows more accurate monitoring of ductal shunt andprovides a good index for treatment of PPHN (persistentUnique SpO 2 probes, BluPRO ®The reusable type finger probecomfortably fits most fingers witha parallel moving mechanism. Thereusable type multi-site probe fitsneonates to adults and its highflexibility allows accurate alignmentof the LED on the infant/neonateinstep. Both are washable, splashprotected, and durable. You canwash it with running water afterdisinfection.The disposable type SpO 2 probe ismade of thin and soft tape with aflat surface for comfortable fit. Theprobe has separate light emitterand light detector parts so you canfor neonate instepplace it in the best position.Optional transmitter for use with acentral monitorThe measured data can be transmitted to the centralmonitor using an optional ZS-900PK transmitter soyou can easily compose a telemetry central monitoringsystem.pulmonary hypertension of the newborn). A delta SpO 2alarm is also available.Battery operationAC and 4-hour battery operation are available. Forcontinued SpO 2 measurement even during transport,<strong>Oxypal</strong> <strong>Neo</strong> can be operated from a built-in battery.This brochure may be revised or replaced by <strong>Nihon</strong> <strong>Kohden</strong> at any time without notice.5945CAT.No.56-005A ´09.03. SZ. E.Printed in Japan on FSC certified Paper

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!