13.07.2015 Views

Panelboards - Siemens

Panelboards - Siemens

Panelboards - Siemens

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

11PANELBOARDS<strong>Panelboards</strong>Modifications and AdditionsP4 <strong>Panelboards</strong>Devices Mounted on Gutter CoverIncludes Device, Mounting – Wired orUnwiredDescriptionOne piece front with doorHinged Gutter Covers 4 pc frontToggle Switch — SPST or 3-way15A, 277V maximumPilot Light — General PurposeNeon or IncandescentPushbuttonIncreased Capacity NeutralAmpere RatingUnit SpacePhase Neutral ( inches)400 600 0400 800 0600 1200 0800 1200 0Subfeed or Feed-Thru Lugs(One Set Per Panel)Subfeed Double Lugs(Main Lug Panels)AmpRating400 0600 0800 N/A1200 N/AFeed-Thru LugsUnit Spaces(Additional inches)MLOAmpere Rating Unit Space (inches)400 10600 10800 17.51200 17.5Fuse Clip Provisions(Add to 250 Volts or 600 VoltsUnit Prices Per Switch)AmpRatingClassJClassR30 • •60 • •100 • •200 • •ClassTSpanner Wrenches(for Vacu-Break Switches)Ground Fault on Main BreakerDescriptionConventional Ground Fault Includes:ground fault relay, ground sensor, CPT& shunt tripTest and Monitor Panel Ground Fault add toSensitrip III breaker priceTime Clocks Sangamo, Tork or Paragon time clockcan be supplied, mounted in panelboardcabinet. For required increase in enclosuredimension, consult local sales office.DescriptionTime clock (1- or 2-Pole, Single orDouble Throw Contacts; 3-Pole SingleThrow)277V Maximum with Plain DialOptional:Astronomical DialAn Omitting DeviceReserve Power or CarryoverSpace and Mounting Provisions OnlySelectionMain BusStandard main bus and ground bus aretin-plated aluminum. For copper mainbus, neutral bus and ground bus, addfrom the table for each panel.Lugs – For Main Lug Only PanelsStandard main lugs and neutral lugsare tin-plated aluminum, UL listed foruse with aluminum/copper cables.Copper only lugs are an option.Ampere Rating400 - 1200Shunt Trip on Main and Branches DescriptionBL, BQD, NGB (branch only)QJ2, QJH2, QJ2H, HQJ2H, NEB, HEB,ED4, ED6, HED4, HHED6, CED6All others to 800A100% Rated Main Circuit BreakersAmpereRating400A600A800ABreakerTypeJXD6H, HJXD6HSCJD6H, SHJD6HNJY, HJY, LJYLXD6H, HLXD6HNMY , HMY , LMY MXD6H, HMXD6H, CMD6HSMD6H, SHMD6H, SCMD6HGrounding of <strong>Panelboards</strong> GroundBars (except for brazed-to-box)are shipped with the panel interiorfactory mounted.▪ Non-Insulated Equipment GroundBar – Standard▪ Copper Non-Insulated Ground Bar▪ Al Insulated Equipment Ground Bar▪ Cu Insulated Equipment Ground Bar▪ Ground Bar Brazed to BoxCircuit Breaker AccessoriesHandle Blocking DeviceBlocks handle in either the“ON” or “OFF” position.Padlocking Device – Padlocksin “OFF” position. Available in 90” high enclosure only. Unit space is 421/2” with Test and Monitor Panel; 45” without Test andMonitor Panel. Not available on Sensitrip III. For required unit space, consult local sales office. Shunt Trip on 100A frame breakers increases mountingheight to 6.25” for twin mounting. The 600A, 100% rated breaker requires the use of an800A frame breaker.11-52<strong>Siemens</strong> Industry, Inc. SPEEDFAX 2011 Product CatalogProduct Category PBSB

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!