IMPORTANT SAFETY NOTICENetworX NX-6 Series Version 2 Software IssueDear (GE <strong>Security</strong> Dealer/Installer):GE <strong>Security</strong> recently identified a software problem on the version 2 NetworX NX-6series of control panels. These units go in<strong>to</strong> a fault mode on the 2-wire smoke zone whenpower is res<strong>to</strong>red after the panel experiences a complete power loss. Although GE<strong>Security</strong> has received no incident reports in which a system failed <strong>to</strong> alarm due <strong>to</strong> thefault, we are working <strong>to</strong> voluntarily replace all NX-6 series products affected byreplacing the main circuit board. We urge you <strong>to</strong> participate in this voluntaryreplacement program <strong>to</strong> help protect the safety of your cus<strong>to</strong>mers. To encourage yourparticipation, GE <strong>Security</strong> is offering a $50 product credit for each panel corrected.Below is important information that you will need <strong>to</strong> participate.This voluntary replacement affects all of the following version 2 NX-6 series modelnumbers:NX-6 NX-648-KIT NX-6-BO-FGNX-6-FP NX-6-FP-1 NX-6-FP-4-LMNX-6-FP-4-LM-MPI NX-6-FP-4-LM-NTS NX-6-FP-7-INTNX-6-FP-8 NX-6-FP-8-LM NX-6-FP-8-SCOTT1NX-6-FP-9-LM NX-6-FP-INT NX-6-FP-LM-12NX-6-KIT NX-6-KIT-12 NX-6-KIT-12-HARTNX-6-KIT-12-LM-LX-GT NX-6-KIT-12-LX NX-6-KIT-4NX-6-KIT-4-LX NX-6-KIT-8 NX-6-KIT-9-LXNX-6-KIT-LXRetrofit of Units Installed in the Field. GE <strong>Security</strong> needs your assistance <strong>to</strong> identifythe cus<strong>to</strong>mers for whom you may have installed an NX-6 version 2 panel with a 2-wiresmoke zone, and encourage them <strong>to</strong> have the main circuit board replaced immediately.To facilitate this replacement, enclosed is a sample letter that you may use <strong>to</strong> send <strong>to</strong> yourcus<strong>to</strong>mers. Notification <strong>to</strong> these cus<strong>to</strong>mers is very important and GE <strong>Security</strong> asks thatyou send these letters or otherwise contact your cus<strong>to</strong>mers directly as soon as possible.GE <strong>Security</strong> will cover the expense of this notification. If you prefer <strong>to</strong> use a differentform of notification or if you would like GE <strong>Security</strong> <strong>to</strong> send these letters directly <strong>to</strong> youraccount list, please contact GE <strong>Security</strong> Cus<strong>to</strong>mer Service at 888 GE SECURITY (888-437-3287).12345 SW Leve<strong>to</strong>n Drive * Tualatin, OR 97062 * 1-800-547-2556


Existing Inven<strong>to</strong>ry. This notice only involves the version 2 of the NX-6 series where 2-wire smoke detec<strong>to</strong>rs were installed. If the version 2 NX-6 series was installed with a 4-wire smoke zone, the fault mode will not occur and the panel will function properly aftera power loss.Additionally, any previous version of the NX-6 series products are not affected. If youhave a product that is packaged with NetworX labels below, those products are notaffected by this recall notice.Obtaining Replacement Boards. After identifying which accounts have systems thatwill need replacement of the main circuit board, please fax the attached order form <strong>to</strong> GE<strong>Security</strong> or call our cus<strong>to</strong>mer service at 888 GE SECURITY (888-437-3287) Monday –Friday 8 a.m. – 8 p.m. EST. We will send you the number of circuit boards requested atno charge. GE <strong>Security</strong> will issue a product credit in the amount of $50 for each panelcorrected.We apologize for the inconvenience that this voluntary product replacement may causeand thank you for your immediate attention <strong>to</strong> this matter. The safety of our cus<strong>to</strong>mers isour highest priority.Sincerely,Shawna RevakSix Sigma Black Belt/Recall Coordina<strong>to</strong>r12345 SW Leve<strong>to</strong>n Drive * Tualatin, OR 97062 * 1-800-547-2556

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!