Fisher 4200 Series Electronic Position Transmitters - Aptec Electronics

Fisher 4200 Series Electronic Position Transmitters - Aptec Electronics Fisher 4200 Series Electronic Position Transmitters - Aptec Electronics

aptecelectronics.com
from aptecelectronics.com More from this publisher
13.07.2015 Views

4200 Series TransmittersProduct Bulletin62.3:4200April 200948(1.88)108(4.25)86(3.40)271(10.69)204(8.00)ACTUATORHOUSING51(2.00)CONNECTIONNUMBER 1CONNECTIONNUMBER 2TYPICAL MOUNTING BRACKET DIMENSIONSFOR SLIDING-STEM ACTUATORSTYPICAL MOUNTING BRACKET DIMENSIONSFOR ROTARY-SHAFT ACTUATORSFISHER 4200 SERIES TRANSMITTER MOUNTING10(0.38)204(8)1111(4.38)GE16563-A / ILMOUNTING BRACKET DIMENSIONS FORFISHER 585CLS ACTUATORSWITH A 152 mm (6-INCH) CHANNELNOTE:1 FOR OTHER SIZES OF 585CLS ACTUATORS, THE MOUNTING PLATELENGTH WILL CHANGE DEPENDING ON THE CHANNEL WIDTH.FISHER 4200 SERIES TRANSMITTER (LONG-STROKE) MOUNTINGFigure 6. Mounting Dimensions8

Product Bulletin62.3:4200April 20094200 Series TransmittersTable 4. Fisher 4211 and 4221 Electronic Position Transmitter EMC Summary Results—ImmunityPORTPHENOMENONBASICPERFORMANCETEST LEVELSTANDARDCRITERIA (1)Electrostatic Discharge (ESD) IEC 61000-4-24 kV contact8 kV airAEnclosure Radiated EM field IEC 61000-4-380 to 1000 MHz @ 10V/m with 1 kHz AM at 80%1400 to 2000 MHz @ 3V/m with 1 kHz AM at 80%A2000 to 2700 MHz @ 1V/m with 1 kHz AM at 80%Rated power frequency magneticfieldIEC 61000-4-8 60 A/m at 50 Hz ABurst (fast transients) IEC 61000-4-4 1 kV ASurge IEC 61000-4-5 1 kV (line to ground only, each) BI/O signal/control150 kHz to 80 MHz at 3 VrmsConducted RF IEC 61000-4-6A1 kHz AM at 80%Specification limit = ±1% of span1. A = No degradation during testing. B = Temporary degradation during testing, but is self-recovering.Table 5. Fisher 4200 Series Electronic Position Transmitter Hazardous Area Classifications—CSA (Canada)CERTIFICATIONBODYCSATYPE CERTIFICATION OBTAINED ENTITY RATING4211, 42214210, 4211,4212, 4215,4220, 4221,42224210, 4211,4212, 4215,4220, 4221,4222(Intrinsic Safety)Class/DivisionClass I,II,III Division 1 GP A,B,C,D,E,F,Gper drawing GE16020(Explosion Proof)ZoneEx d IIC T5Class/DivisionClass I, Division 1 GP B,C,D T5U i = 30 VDCI i = 150 mAP i = 1.0 WC i = 5 nFL i = 0 mHTEMPERATURECODET4(T amb 71°C)ENCLOSURERATING4X− − − T5 (T amb 71°C) 4XClass II Division 1 GP E,F,G T5 − − − T5 (T amb 71°C) 4XTable 6. Fisher 4200 Series Electronic Position Transmitter Hazardous Area Classifications—FM (United States)CERTIFICATIONBODYFMTYPE CERTIFICATION OBTAINED ENTITY RATING4211, 42214210, 4211,4212, 4215,4220, 4221,42224211, 42214210, 4211,4212, 4215,4220, 4221,4222(Intrinsic Safety)Class/DivisionClass I,II,III Division 1 GP A,B,C,D,E,F,Gper drawing GE16019(Explosion Proof)ZoneClass I Zone 1 AEx d IIC T5Class/DivisionClass I, Division 1 GP A,B,C,D T5Class I Division 2 GP A,B,C,D T5Class II Division 2 GP F,G T5V max = 30 VDCI max = 150 mAP i =1.0 WC i = 5 nFL i = 0 mHTEMPERATURECODET4 (T amb 71°C)ENCLOSURERATING4X− − − T5 (T amb 71°C) 4X− − − T5 (T amb 71°C) 4XClass II Division 1 GP E,F,G T5 − − − T5 (T amb 71°C) 4X9

<strong>4200</strong> <strong>Series</strong> <strong>Transmitters</strong>Product Bulletin62.3:<strong>4200</strong>April 200948(1.88)108(4.25)86(3.40)271(10.69)204(8.00)ACTUATORHOUSING51(2.00)CONNECTIONNUMBER 1CONNECTIONNUMBER 2TYPICAL MOUNTING BRACKET DIMENSIONSFOR SLIDING-STEM ACTUATORSTYPICAL MOUNTING BRACKET DIMENSIONSFOR ROTARY-SHAFT ACTUATORSFISHER <strong>4200</strong> SERIES TRANSMITTER MOUNTING10(0.38)204(8)1111(4.38)GE16563-A / ILMOUNTING BRACKET DIMENSIONS FORFISHER 585CLS ACTUATORSWITH A 152 mm (6-INCH) CHANNELNOTE:1 FOR OTHER SIZES OF 585CLS ACTUATORS, THE MOUNTING PLATELENGTH WILL CHANGE DEPENDING ON THE CHANNEL WIDTH.FISHER <strong>4200</strong> SERIES TRANSMITTER (LONG-STROKE) MOUNTINGFigure 6. Mounting Dimensions8

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!