installation instructions, care and maintenance penguin model524 ...

installation instructions, care and maintenance penguin model524 ... installation instructions, care and maintenance penguin model524 ...

pdf.lowes.com
from pdf.lowes.com More from this publisher
13.07.2015 Views

7) INSTALL TANKa. Slide new sponge rubbergasket (small side down)onto threaded end offlush valve.b. Install 2 bolts as follows:Slide rubber washer underbolt head and insert boltthrough tank. Install brasswasher, then thread hexnut onto bolt. Carefullytighten bolt until snug. DONOT OVERTIGHTEN ortank may crack.c. Place tank back on bowlso that sponge gasketfits evenly. Level tankand bowl.d. Install rubber washer,brass washer, and wingnut onto bolt. Repeat forthe other side. Tightennuts evenly. DO NOTOVERTIGHTEN or tankmay crack.8) INSTALL TOILET SEATa. Install toilet seat in accordance with manufacturer’s directions.9) CONNECT WATER SUPPLYa. Before continuing, determine the type of water supply connection you have from the chart below and use the appropriate assemblyparts required to properly re-connect the water supply. DO NOT use plumber’s putty to seal these fittings.METAL/COPPERFLARED TUBINGThese parts must be usedas illustrated to insure awater-tight connection. Useof existing coupling nut mayresult in water leakage.Water supply tube or pipemust extend at least 1/2"inside threaded shank ofvalve (does not apply toflanged tubing).METAL FLANGED TUBINGUse existing coupling nutand washer.METAL SPIRAL TUBINGUse existing spiral conewasher. Fluidmaster conewasher may not sealcompletely on spiral typesupply line.VINYL/BRAIDEDCONNECTORCaptive cone washersalready included. Noadditional washers needed.b. With correct washers in place (See previous step), tightenCOUPLING NUT 1/4 turn beyond hand tight. DO NOTOVERTIGHTEN.2

10) ADJUSTMENTSa. Adjust water level. Water level should be adjusted to levelindicated on tank by adjusting the float cup. See Step 11 forwater level adjustment method.b. If bowl fails to siphon, an adjustment may be required with thelift chain. Simply remove the bead chain from the retainer clip,take up slack on the chain and re-insert on lift rod. Make surethe chain is not too taut.11) ADJUST WATER LEVELa. Turn on water supply. Submergethe FLOAT CUP under the waterfor 30 seconds. Adjust the waterto desired level by turningWATER LEVEL ADJUSTMENTROD and moving FLOAT CUP upor down.b. Once water level is correct withmarking in tank, flush toilet 3 timesto prime toilet and “No Overflow”system. After prime has beenestablished toilet traps are self-priming from this point on. Nofurther priming is required. Use toilet for normal use.12) CARE AND CLEANINGa. When cleaning your toilet, wash it with mild, soapy water, rinsethoroughly with clear water and dry with a soft cloth. Avoiddetergents, disinfectants, or cleaning products in aerosol cans.NEVER use abrasive scouring powders or abrasive pads onyour toilet seat. Some bathroom chemicals and cosmetics maydamage the seat’s finish.b. This toilet has a “No Overflow” feature that requires little or nomaintenance. There are 3 holes inside the back of the bowl. Ifthe toilet ever gets plugged in the main trap, water in the bowlwill exit through these holes. During every flush a small amountof water fills a reservoir that prevents sewer gas from comingup through these holes. If the toilet hasn’t been flushed for anextended period (vacation) this water may get stale and smell.Simply flush the toilet to bring fresh water into the reservoir.WARNING: Do not use in-tank cleaners. Products containingchlorine (calcium hypochlorite) can seriously damage fittings inthe tank. This damage can cause leakage and property damage.Penguin shall not be responsible or liable for any tank fittingdamage caused by the use of cleaners containing chlorine(calcium hypochlorite).13) TROUBLESHOOTINGDIAGRAM 1: IMPORTANT:Always clear sand and rustfrom system. Make sure watersupply is off. Remove valveTOP by lifting arm and rotatingtop and arm 1/8 turn counterclockwise,pressing downslightly on cap.DIAGRAM 2: While holding acontainer over the uncappedVALVE to prevent splashing,turn water supply on and off afew times. Leave water supplyoff.DIAGRAM 3: Replace TOP byengaging lugs and rotating 1/8turn clockwise. MAKECERTAIN TIP IS TURNED TOTHE LOCKED POSITION.VALVE MAY NOT TURN ON IFTOP IS NOT FULLY TURNEDTO THE LOCKED POSITION.IF FILL VALVE SHUTS OFF BUT CONTINUES TO LEAK SLOWLY:: Repeat Step 13.IF FILL VALVE TURNS OFF AND ON DURING PERIODS OF NON-USE: It is a signal you are wasting water because:a. The end of the refill tube is inserted into overflow pipe, below water level in tank. Attach refill tube to overflow pipe using “S” clipprovided.b. The flush valve is leaking because it’s worn, dirty or misaligned with tank ball or flapper (replace with a new flapper).IF FILL VALVE WON’T TURN ON OR SHUT OFF or REFILL OF TANK WATER IS SLOW (After valve has been in use forsome time). Fluidmaster Model 242 Replacement Seal may be needed. 3

7) INSTALL TANKa. Slide new sponge rubbergasket (small side down)onto threaded end offlush valve.b. Install 2 bolts as follows:Slide rubber washer underbolt head <strong>and</strong> insert boltthrough tank. Install brasswasher, then thread hexnut onto bolt. Carefullytighten bolt until snug. DONOT OVERTIGHTEN ortank may crack.c. Place tank back on bowlso that sponge gasketfits evenly. Level tank<strong>and</strong> bowl.d. Install rubber washer,brass washer, <strong>and</strong> wingnut onto bolt. Repeat forthe other side. Tightennuts evenly. DO NOTOVERTIGHTEN or tankmay crack.8) INSTALL TOILET SEATa. Install toilet seat in accordance with manufacturer’s directions.9) CONNECT WATER SUPPLYa. Before continuing, determine the type of water supply connection you have from the chart below <strong>and</strong> use the appropriate assemblyparts required to properly re-connect the water supply. DO NOT use plumber’s putty to seal these fittings.METAL/COPPERFLARED TUBINGThese parts must be usedas illustrated to insure awater-tight connection. Useof existing coupling nut mayresult in water leakage.Water supply tube or pipemust extend at least 1/2"inside threaded shank ofvalve (does not apply toflanged tubing).METAL FLANGED TUBINGUse existing coupling nut<strong>and</strong> washer.METAL SPIRAL TUBINGUse existing spiral conewasher. Fluidmaster conewasher may not sealcompletely on spiral typesupply line.VINYL/BRAIDEDCONNECTORCaptive cone washersalready included. Noadditional washers needed.b. With correct washers in place (See previous step), tightenCOUPLING NUT 1/4 turn beyond h<strong>and</strong> tight. DO NOTOVERTIGHTEN.2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!