13.07.2015 Views

SIRIUS Soft Starters - Siemens

SIRIUS Soft Starters - Siemens

SIRIUS Soft Starters - Siemens

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Overview of <strong>SIRIUS</strong> <strong>Soft</strong> <strong>Starters</strong>Technical DataOverview of <strong>SIRIUS</strong> soft starters Standard applications High-featureapplications<strong>SIRIUS</strong> 3RW30<strong>SIRIUS</strong> 3RW40quip nialet <strong>SIRIUS</strong> erxit 3RW44Rated current at 40 ºC A 3.6 ... 106 12.5 ... 432 29 ... 1214Rated voltage V 200 ... 480 200 ... 600 200 ... 690Motor power with 400 V (standard circuit) kW 1.1 ... 55 5.5 ... 250 15 ... 710Motor power with 400 V (inside-delta circuit) kW – – 22 ... 1214Ambient temperature (operation) °C –25 ... 60 –25 ... 60 0 ... 60<strong>Soft</strong> start/stop x 1) x xVoltage ramp x x xStarting/stopping voltage % 40 ... 100 40 ... 100 20 ... 100Ramp-up and ramp-down time s 0 ... 20 1) 0 ... 20 1 ... 360Torque control – – xStarting/stopping torque % – – 20 ... 100Torque limiting % – – 20 ... 100Ramp time s – – 1 ... 360Integrated bypass contact system x x xIntrinsic device protection – x xMotor overload protection – x 7) xThermistor motor protection – x 2) xIntegrated remote reset – x 3) xSettable current limiting – x xInside-delta circuit – – xBreakaway torque – – xCreep speed in both directions of rotation – – xPump stop – – x 4)4) 5)DC braking – – x4) 5)Combined braking – – xMotor heating – – xCommunication – – with PROFIBUS DP (option)External display and operator module – – (option)Status measured value display – – xError log – – xEvent list – – xNon-return pointer function – – xTrace function – – x 6)Programmable control inputs and outputs – – xNumber of parameter sets 1 1 3Parameterization software (<strong>Soft</strong> Starter ES) – – xPCS 7 faceplates – – xPower semiconductors (thyristors) 2 controlled phases 2 controlled phases 3 controlled phasesScrew-type terminals x x xSpring-loaded terminals x x xUL/CSA x x xCE mark x x x<strong>Soft</strong> starting and heavy-duty starting conditions – – x 4)Configuration supportWin-<strong>Soft</strong> Starter, electronic selection slide,Technical Assistance +49 911 895 5900221) 3RW30 only soft start2) Optionally up to size S3 (device version)3) With 3RW40 2. up to 3RW40 4.; with 3RW40 5. and 3RW40 7. optional4) Overdimensioning of soft starter and motor if required5) Not possible with inside-delta circuit6) Trace function with <strong>Soft</strong> Starter ES software7) Motor overload protection (ATEX) tobe used in combination with a contactorX = Function available– = Function not available

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!